GE JGBP38 installation instructions Electrical Connections, Electric Disconnect

Page 40

INSTALLATION INSTRUCTIONS

(continued)

ELECTRICAL CONNECTIONS (continued)

AUsage Situations where Appliance Power Cord will be Disconnected Infrequently.

An adapter may be used only on a 15-amp circuit. Do not use an adapter on a 20-amp circuit. Where local codes permit, a TEMPORARY CONNECTION may be made to a properly grounded two-prong wall receptacle by the use of a UL-listed adapter, available at most hardware stores. The larger slot in the adapter must be aligned with the larger slot in the wall receptacle to provide proper polarity in the connection of the power cord.

TEMPORARY

METHOD

(Adapter plugs not permitted in Canada)

Align large

 

Ensure proper

prongs/slots

ground and

 

 

firm connection

 

before use

CAUTION: Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal, and not insulated, and the wall receptacle is grounded through the house wiring. The customer should have the circuit checked by a qualified electrician to make sure the receptacle is properly grounded.

When disconnecting the power cord from the adapter, always hold the adapter with one hand. If this is not done, the adapter ground terminal is very likely to break with repeated use. Should this happen, DO NOT USE the appliance until a proper ground has again been established.

BUsage Situations where Appliance Power Cord will be Disconnected Frequently.

Do not use an adapter plug in these situations because disconnecting of the power cord places undue strain on the adapter and leads to eventual failure of the adapter ground terminal. The customer should have the two-prong wall receptacle replaced with a three-prong (grounding) receptacle by a qualified electrician before using the appliance.

The installation of appliances designed for mobile home installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280) or, when such standard is not applicable, the Standard for Manufactured Home Installations, latest edition (Manufactured Home Sites, Communities and Set-Ups), ANSI A225.1, latest edition, or with local codes. In Canada, mobile home installation must be in accordance with the current CAN/CSA Z240/MH Mobile Home Installation Code.

Electric Disconnect

1.Locate disconnect plug on the range back.

2.Pinch sides of connector and pull out of range back.

40

Image 40
Contents Consumer Services Safety InstructionsOperating Instructions, Tips If YOU Need Service Help US Help YOU…When You Get Your Range Important Safety InstructionsUsing Your Range Surface Cooking Always heat fat slowly, and watch as it heatsClean only parts listed in this Use and Care Guide Self-Cleaning OvenBaking, Broiling and Roasting Features of Your Range Features and appearance may varyFeature Index See Night Light Switch on some models Oven Vents CooktopModel and Serial Numbers Anti-Tip DeviceHOW does this Cooktop Compare To Your OLD ONE? Type of Cooktop Description How it Works Gas BurnersSurface Cooking Top-of-Range Cookware Features of Your Oven Control Appearance may varyOven CONTROL, Clock and Timer Using Your Oven Oven Vents Oven ShelvesShelf Positions Shelves are designed with stop-locks so whenBaking How to Set Your Range for BakingPreheating Pan Placement Baking GuidesCookies Aluminum FoilHow to Time Bake How to Set Immediate Start and Automatic StopTimed Baking Don’t PeekHow to Set Delay Start and Automatic Stop Quick ReminderAdjust the Oven Thermostat Do IT YourselfUse of Aluminum Foil RoastingDual Shelf Cooking Questions and Answers Why is my roast crumbling when I try to carve it?Roasting Guide Frozen RoastsWhy are my meats not turning out as brown as they should? BroilingOven door must be closed during broiling Close the oven doorBroiling Guide Beef SteaksOperating the SELF-CLEANING Oven Before a Clean CycleTo Stop a Clean Cycle How to Set the Oven for CleaningAfter a Clean Cycle How to Delay Start of Cleaning Quick Reminder-Delay Start for Self-CleanShould there be any odor during the cleaning? Why do I have ash left in my oven after cleaning?Care and Cleaning Sealed Burner Assemblies on some modelsRemove the grates and lift out the drip pans Standard Twin Burners on some modelsTo get rid of burned-on food, place them in a Burner Grates Cooktop SurfaceBrushed Chrome Cooktop on some models Oven BottomLift-Off Oven Door Broiler Pan and GridControl Panel and Knobs Oven Light Replacement on some modelsRemovable Storage Drawer on some models Removable Kick Panel on some models Oven Air VentsFluorescent Night Light on some models Installation Instructions For Your SafetyImportant Safety Instructions General Provide Adequate GAS Supply Connect the Range to GASConnect the Range to GAS Rigid Pipe Hookup for Models Equipped with Sealed BurnersElectrical Connections on some models GroundingElectrical Requirements Extension Cord CautionsElectrical Connections Electric DisconnectSeal the Openings Check Ignition of Surface BurnersSurface Burner Ignition Quality of FlamesTo remove the oven bottom Installing the ANTI-TIP Device Leveling the RangeConverting to LP GAS Sealed Burner models only Tools RequiredPrepare Range for Conversion Convert the Pressure RegulatorConverting Surface Burners Orifice Spuds for Converting to LP GasOrifice Spuds for Converting to Natural Gas Convert the Oven Burner OrificesAdjust LOW Flame Setting Convert AIR Adjustment ShutterBroil Burner Check for LeaksConverting to LP GAS Standard Twin Burner models only NATConvert the Oven Burner Orifices Oven Burner Top Burner Orifice Drill Size ColorAdjust Oven Thermostat Adjust the Surface Burner PilotsQUESTIONS? USE this Problem Solver Problem Possible CauseProblem Solver Problem Solver Not UnlockProblem Solver Page We’ll Be There Warranty