Installing 3-Wire Power Cord

Refer to power cord instructions if available for additional information.

1.Remove rear wire cover on rear of range.

2.Place cord clamp (winged clamp) in cord access hole below terminal block.

Cord clamp is supplied with cord. Place wings through hole, entering from bottom. Screw holes in clamp should be below mounting panel. Place cord through strain relief.

3.Attach neutral (center) or white wire to center terminal on terminal block.

4.Attach power lead, red wire or black wire to left side power terminal.

5.Attach power lead, red wire or black wire to the right side power terminal.

6.After wires have been placed on terminals, attach with hex nuts provided.

Firmly tighten to ensure proper electrical connection.

7.Place screw through cord clamp and tighten.

8.Replace rear wire cover.

Wires from range

(Number of wires on each terminal can vary)

 

A

 

 

 

 

 

 

B

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wires from power cord

A—240 or 208 power lead terminal (Connect black or red insulated wire and secure with brass nut.)

B—Neutral terminal (Connect insulated white insulated wire and secure with brass nut.)

Installing 3-Wire Power Cord

Installing 4-Wire Power Cord

!WARNING

To avoid the risk of severe electrical shock or death, ground wire must be attached to frame of range, using ground screw provided. Ground wire must not contact any other terminal.

1.Remove rear wire cover on back of range.

2.Place cord clamp (winged clamp) in cord access hole below terminal block.

Cord clamp is supplied with cord. Place wings through hole entering from bottom.

Screw holes in clamp should be below mounting panel.

3.Remove green ground screw (retain for use in step 7) and unscrew brass nut on center terminal. Remove grounding strap.

Wires from range

(Number of wires on each terminal can vary)

Center terminal nut

Grounding

strap

Green ground screw

Remove Green Ground Screw

4.Place cord through strain relief.

5.Attach cord neutral (center) or white wire to center terminal on terminal block. Secure with hex nuts provided.

6.Attach power lead, red wire or black wire to left terminal. Secure with hex nuts provided.

8

Image 8
Contents Customer InstallerPlease Read Manual Before Operating Range Contents Important Safety Information Precautions Case of FireSurface Element Fire Oven FiresInstallation Packing MaterialRange Location Cabinet OpeningAnti-tip Bracket Installation Power Supply LocationIrregular Cabinet and Countertop Heights Line Voltage RequirementsPower Cord Requirements Neutral terminal connect wirePower terminals Range Terminal BlockInstalling 3-Wire Power Cord Installing 4-Wire Power CordLevel Range Converting 3-Wire to 4-Wire Power CordRemoval and Replacement of Range Range Features OperationElectronic Clock and Timer Some Models Setting Electronic ClockSetting Electronic Timer Canceling Electronic TimerSettings Operating Surface ElementsRemove Items Stored in Oven Oven Rack PlacementPrepare to Bake Baking BroilingPreheating Broiling TipsFood Oven Temperature Cooking Time Cooking GuideBaking Guide Poultry Roasting GuideFood Thickness Rack position Cooking time Beef and Pork Roasting GuideBroiling Guide Care and Cleaning Removing Oven DoorRemoving Panel Some Models Replacing Oven Light Some ModelsCleaning Part Materials to Use General Directions Check Before Calling for ServiceProblem Warranty Cooking Products excluding wall ovens