Verona VEFSGG 365 ND warranty Conversion To Lp/Propane Gas, SETTING THE PRESSURE REGULATOR .5

Page 19

CONVERSION TO LP/PROPANE GAS

Every range is provided with a set of injectors for the various types of gas.

Select the injectors to be replaced according to the “INJECTORS TABLE”.

The nozzle diameters, expressed in hundredths of a millimetre, are marked on the body of each injector.

SETTING THE PRESSURE REGULATOR (fig. 2.5)

The pressure regulator is accessible through the storage compartment by opening the bottom pivoting panel; the pressure regulator is positioned on the rear right side of the range.

To set the pressure regulator:

1.Unscrew the regulator cover;

2.Unscrew the A component, reverse and screw it according to the LP/PROPANE regulation.

Pressure regulator

REGULATOR

COVER

1

2

A component

LP/PROPANE

NATURAL GAS

REGULATION

REGULATION

Fig. 2.5 19

Image 19
Contents Double Oven GAS Range ALL Ranges can TIP DATA PLATE Conversion Label Installation Instructions Electrical Grounding Instructions Replacement PartsProximity to Side Cabinets  installationGAS and Electric Connection Oven 305 Levelling the Cooker Fitting the Adjustable FeetMoving the Cooker Backguard or the island trim It is mandatory to installASSEMBLING THE BACKGUARD OR THE ISLAND TRIM28 15/16 735 mm Explosion Hazard Manual Shut-off Valve .1Pressure Regulator Lock Pressure Regulator InstallationImportant use two spanners to tighten the connection Page Range Manifold Manifold male Pipe fitting Flexible Connections Leak TestingRigid Pipe Connections CONVERSION TO LP/PROPANE GAS SETTING THE PRESSURE REGULATOR .5INJECTORS TABLE Operations to be Performed When Substituting InjectorsSemirapid and triple ring burners Setting the Burner MinimumOven Burner LEFT and RIGHT OVEN Adjustment of the Oven Burner MinimumRecommended ground method Electrical connectionWiring Diagram Page Page Cod ß1