INJECTORS TABLE
BURNERS
NOMINAL POWER
BTU/hr
REDUCED POWER
BTU/hr
LP/PROPANE | NATURAL GAS |
11" W.C.P. | 4" W.C.P. |
|
|
Ø injector | Ø injector |
[1/100 mm] | [1/100 mm] |
|
|
6000 | 1500 | 72 | 118 | |||
|
|
|
|
|
| |
Triple ring (TR) | 12000 | 5000 | 102 | 170 | ||
|
|
|
|
|
| |
| Inner crown | 2800 for NATURAL GAS (*) | 1000 (*) | 55 | 80 | |
| 3500 for LP/PROPANE GAS (*) | (no. 1 central) | (no. 1 central) | |||
|
|
| ||||
Dual (D) |
|
|
|
|
| |
Outer crown | 16000 for NATURAL GAS (#) | 6500 for NATURAL GAS (*) | 72 | 130 | ||
| ||||||
| 15000 for LP/PROPANE GAS (#) | 4500 for LP/PROPANE GAS (*) | (no. 2 outer) | (no. 2 outer) | ||
|
| |||||
|
|
|
|
|
| |
Oven burner (left) | 13000 | 1500 | 109 | 180 | ||
|
|
|
|
| ||
Oven burner (right) | 9000 | 1400 | 88 | 145 | ||
|
|
|
|
| ||
Broil burner (left) | 8500 | - | 88 | 146 | ||
|
|
|
|
| ||
Broil burner (right) | 8000 | - | 83 | 140 | ||
|
|
|
|
|
|
(*) Power calculated only with inner crown operating
(#) Power calculated with inner and outer crowns operating
J
Fig. 2.6a
Triple ring burner
J
Fig. 2.6b
OPERATIONS TO BE
PERFORMED WHEN
SUBSTITUTING THE
INJECTORS
✓Remove the gratings and the burner covers;
✓Using a wrench substitute the nozzle injectors “J” (figs. 2.6a - 2.6b - 2.6c) with those most suitable for the kind of gas for which it is to be used.
The burner are conceived in such a way so as not to require the regulation of the primary air.
DUAL burner
J
Injector for inner crown
J
Injectors for outer crowns
Fig. 2.6c
20