Verona VEFSGG 365 ND warranty  installation, Proximity to Side Cabinets

Page 6

installation

PROXIMITY TO SIDE CABINETS

1.This range may be installed directly adjacent to existing 36" (914 mm) high base cabinets.

Range dimensions:

width: 35” 7/8 (911 mm)

depth: 23” 31/32 (609 mm)

height (without backguard / island trim): MIN 35” 7/16

(900mm) MAX 37” 13/32 (950 mm)

backguard (height): 8” (203 mm)

island trim (height): 3” (76mm)

Gas line opening:

Wall - 7” 15/32 (190 mm) from the floor; 15” 3/4 (400 mm) from the rear right side of the range.

Grounded outlet: the electric cord with 3-prong ground plug has a length of 72” (1830 mm). Grounded outlet should be located 20” 1/8 (511 mm) from the left side to centre of range and from 5” 1/8 (130 mm) to 7” 3/32 (180 mm) [depending on feet regulation] from the floor.

2.The range CANNOT be installed directly adjacent to side- walls, tall cabinets, tall appliances, or other side vertical surfaces above 36” (914 mm) high.

There must be a minimum of 11” 13/16 (300 mm) side clear- ance from the range to such combustible surfaces TO THE LEFT or TO THE RIGHT above the 36” (914 mm) high coun- tertop.

IMPORTANT: One side (left or right) above the 36” (914 mm) high countertop must always be kept clear.

Installation with island trim: There must be a minimum of 12” (305 mm) clearance from the back of the island trim to such combustible surface on the back of the range above the 36” (914 mm) high countertop.

3.The maximum upper cabinet depth recommended is 13” (330

mm).Wall cabinet above the range must be a minimum of 30”

(762 mm) above the countertop for a width of minimum 35” 7/8 (911 mm): it has to be centred with the range. Side wall cabinets above the range must be a minimum of 18” (457

mm)above the countertop.

8"

(900 mm)

mm)

 

 

Backguard

23"

31/32

 

(203

(609

 

mm)

 

 

 

(950 mm)

Island trim

3"

(76mm)

23"

31/32

(609

 

mm)

 

 

 

(900 mm)

(950 mm)

 

 

 

MIN 35" 7/16

MAX 37" 13/32

Fig. 1.1a

35"

7/8

mm)

 

(911

MIN 35" 7/16 MAX 37" 13/32

35"

7/8

mm)

 

(911

Fig. 1.1b

6

Image 6
Contents Double Oven GAS Range ALL Ranges can TIP DATA PLATE Conversion Label Installation Instructions Replacement Parts Electrical Grounding Instructions installation Proximity to Side CabinetsGAS and Electric Connection Oven 305 Fitting the Adjustable Feet Levelling the CookerMoving the Cooker OR THE ISLAND TRIM It is mandatory to installASSEMBLING THE BACKGUARD Backguard or the island trim28 15/16 735 mm Manual Shut-off Valve .1 Explosion HazardPressure Regulator Pressure Regulator Installation LockImportant use two spanners to tighten the connection Page Range Manifold Manifold male Pipe fitting Leak Testing Flexible ConnectionsRigid Pipe Connections SETTING THE PRESSURE REGULATOR .5 CONVERSION TO LP/PROPANE GASOperations to be Performed When Substituting Injectors INJECTORS TABLESetting the Burner Minimum Semirapid and triple ring burnersOven Burner Adjustment of the Oven Burner Minimum LEFT and RIGHT OVENElectrical connection Recommended ground methodWiring Diagram Page Page Cod ß1