Verona VEFSGE 365 ND manual Wire Power Cord Installation

Page 23

3-Wire Power Cord Installation

(See Figures 3.1, 3.2 and 3.3)

1.

Remove the Terminal Block Access Plate on the back of the

 

range by unscrewing the 6 fixing Screws (fig. 3.1).

2.

Insert the Power Cord through the hole in the Power Cord

 

Bracket; then tighten the Power Cord by using a suitable

 

Strain Relief. Allow enough slack to easily attach the cord

 

terminals to the Terminal Block.

3.

Remove the 3 wire terminal nuts and washers from the

 

Terminal Block.

4.

Plug the terminal holes of Power Cord. The Neutral or

 

Ground Wire of the Power Cord must be connected to the

 

neutral terminal located in the center of Terminal Block. The

 

Power Wires must be connected to the outside terminals.

5.

Plug washers and tighten nuts securely.

Fig. 3.1

Screws

Terminal Block

Access Plate

Do not remove Ground strap.

6. Assemble the Terminal Block Access Plate.

4-Wire Power Cord Installation

(See Figures 3.1, 3.2 and 3.4)

Fig. 3.2

Power Cord

Bracket

Hole D 1" 9/64 (29 mm)

1.

Remove the Terminal Block Access Plate on the back of the

 

range by unscrewing the 6 fixing Screws (fig. 3.1).

2.

Insert the Power Cord through the hole in the Power Cord

 

Bracket; then tighten the Power Cord by using a suitable

 

Strain Relief. Allow enough slack to easily attach the cord

 

terminals to the Terminal Block.

3.

Remove the 3 wire terminal nuts and washers from the

 

Terminal Block.

4.

Remove the Ground Strap from the frame of range and

 

terminal by removing its screw and cutting it as shown in

 

Figure 3.4.

5.

Plug the terminal holes of Power Cord. The Neutral Wire of

 

the Power Cord must be connected to the neutral terminal

 

located in the center of Terminal Block; the Power Wires

 

must be connected to the outside terminals; the Ground Wire

 

must be attached to the frame of range by using the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Ground) identified Grounding Screw.

 

 

 

 

 

 

 

6.

Plug washers and tighten nuts securely.

Fig. 3.3

Ground strap

Terminal Block

Tighten the Power Cord

by using a suitable Strain Relief

Neutral Wire

Power Wires

Power Cord

7. Assemble the Terminal Block Access Plate.

Fig. 3.4

Cut Ground Strap

Terminal Block

Grounding

Screw

Grounding Wire

Neutral Wire

Power Wires

Tighten the Power Cord

Power Cord

by using a suitable Strain Relief

 

23

Image 23
Contents Double Oven Dual Fuel Range ALL Ranges can TIP DATA PLATE Conversion Label Installation Instructions Electrical Grounding Instructions Replacement PartsProximity to Side Cabinets  installationGAS and Electric Connection Oven Vent 305 Moving the Cooker Fitting the Adjustable FeetLevelling the Cooker OR THE ISLAND TRIM ASSEMBLING THE BACKGUARD2631/32685 mm ANTI-TIP Stability Device Installation InstructionsGas connection Lock Pressure Regulator InstallationRegulator cover Page Range Manifold Flexible Connections SETTING THE PRESSURE REGULATOR .5 INJECTORS TABLE Operations to be Performed When Substituting InjectorsSemirapid and triple ring burners Setting the Burner MinimumElectrical Connection with Conduit Electrical Connection with Power CordElectrical Requirements Wire Power Cord Installation Wire Conduit Installation Electric Diagram KEY Wiring DiagramPage Page Cod ß1