SETTING THE BURNER MINIMUM |
| |||
When switching from one type of gas to another, the minimum flow rate must also be |
| |||
correct: the flame should not go out | even when passing suddenly from maximum to |
| ||
minimum flame. |
|
|
| |
To regulate the flame follow the instructions below: |
| |||
Semirapid and triple ring burners |
| |||
|
|
| ||
position |
| F | ||
|
| |||
|
|
| ||
– With a thin screwdriver turn the screw "F" until adjustment is correct (fig. 2.7). |
| |||
Inside crown of DUAL burner |
| Fig. 2.7 | ||
|
| |||
|
|
| ||
position |
| |||
|
| H | ||
– Using a screwdriver turn the screw "H" until the correct setting is obtained (fig. 2.8). | ||||
| ||||
Outside crowns of DUAL burner |
| G | ||
|
| |||
|
|
| ||
position |
|
| ||
|
|
| ||
– Using a screwdriver turn the screw "G" until the correct setting is obtained (fig. 2.8). |
|
For LP/PROPANE gas, tighten the adjustment screws completely.
Fig. 2.8
21