Verona VEFSGE 365 ND manual Wire Conduit Installation

Page 24

Fig. 3.5

Counduit

Bracket

Hole D 7/8" (22.5 mm)

Fig. 3.6

Ground strap

Terminal Block

Neutral Wire

Power Wires

Conduit Clamp

Conduit

Fig. 3.7

Cut Ground Strap

Terminal Block

Grounding

Screw

Grounding Wire

Neutral Wire

Power Wires

Conduit Clamp

Conduit

3-Wire Conduit Installation

(See Figures 3.1, 3.5 and 3.6)

1.Remove the Terminal Block Access Plate on the back of the range by unscrewing the 6 fixing Screws (fig. 3.1).

2.Feed 1/2” (1.3 cm) trade size Conduit through the hole in the Conduit Bracket and secure to the Conduit Bracket with a Conduit Clamp.

3.Remove the 3 wire terminal nuts and washers from the Terminal Block.

4.Plug the terminal holes of conductors. The Neutral or Ground Wire of the Power Cord must be connected to the neutral terminal located in the center of Terminal Block. The Power Wires must be connected to the outside terminals.

5.Plug washers and tighten nuts securely. Do not remove Ground strap.

6.Assemble the Terminal Block Access Plate.

4-Wire Conduit Installation

(See Figures 3.1, 3.5 and 3.7)

1.Remove the Terminal Block Access Plate on the back of the range by unscrewing the 6 fixing Screws (fig. 3.1).

2.Feed 1/2” (1.3 cm) trade size Conduit through the hole in the Conduit Bracket and secure to the Conduit Bracket with a Conduit Clamp.

3.Remove the 3 wire terminal nuts and washers from the Terminal Block.

4.Remove the Ground Strap from the frame of range and terminal by removing its screw and cutting it as shown in Figure 3.7.

5.Plug the terminal holes of conductors. The Neutral Wire of the Power Cord must be connected to the neutral terminal located in the center of Terminal Block; the Power Wires must be connected to the outside terminals; the Ground Wire must be attached to the frame of range by using the (Ground) identified Grounding Screw.

6.Plug washers and tighten nuts securely.

7.Assemble the Terminal Block Access Plate.

24

Image 24
Contents Double Oven Dual Fuel Range ALL Ranges can TIP DATA PLATE Conversion Label Installation Instructions Replacement Parts Electrical Grounding Instructions installation Proximity to Side CabinetsGAS and Electric Connection Oven Vent 305 Fitting the Adjustable Feet Levelling the CookerMoving the Cooker ASSEMBLING THE BACKGUARD OR THE ISLAND TRIMANTI-TIP Stability Device Installation Instructions 2631/32685 mmGas connection Pressure Regulator Installation LockRegulator cover Page Range Manifold Flexible Connections SETTING THE PRESSURE REGULATOR .5 Operations to be Performed When Substituting Injectors INJECTORS TABLESetting the Burner Minimum Semirapid and triple ring burnersElectrical Connection with Power Cord Electrical RequirementsElectrical Connection with Conduit Wire Power Cord Installation Wire Conduit Installation Wiring Diagram Electric Diagram KEYPage Page Cod ß1