Xantrex Technology 815-2024, 815-3024 manual Func button, Down and Up arrow buttons, Enter button

Page 31

Freedom SW 3K2K InvChg Owners Guide.book Page 17 Wednesday, October 9, 2013 1:34 PM

Operating the Freedom SW with the SCP

Item

Description

1AC In/Charge light indicates that qualified AC is present at the input of an inverter/charger. When the Freedom SW is connected to a qualified AC source like the utility grid or a generator, this light on the SCP illuminates.

2Inverter On light illuminates when the Freedom SW is inverting using battery power.

3Low Battery light illuminates when the battery voltage on the Freedom SW is low.

4Fault light indicates a condition that requires user attention and intervention. The Fault light illuminates when any Xanbus-enabled device connected to the network is in fault. See “Fault Types” on page 67 for the definitions of a fault and warning.

5STBY/ON Fault Clear button is used to clear active faults on the system if pressed momentarily. It also toggles all Xanbus-enabled devices on the system between Operating and Power Save (Safe) mode when held down for more than five seconds. See “Inverter Operation Using the Front Panel” on page 12.

6Screen displays menus, settings, and system information. Displays a menu screen title, four lines of menu items, and a line that contains small arrows that depict pointers to SCP buttons.

Item

Description

7Func button:

Cancels selection of a menu item.

Returns you to the previous screen.

Changes the functions of the Up and Down arrow buttons.

8(and 9) Down (and Up) arrow buttons:

Scrolls down (up) one line of text.

Decreases (increases) a selected value.

When the Func button is pressed to select:

Shr” - the down (and up) arrow buttons increment (decrement) shore power breaker capacity on a Freedom SW inverter/chargera.

AGS” - the down (and up) arrow buttons switch between different AGS Start modes (Auto, Manual- On, Manual-Off).

Home” - the down (and up) arrow buttons enable or disable the inverter.

See “Soft Key Navigation” on page 20 for more information.

10Enter button:

Confirms selection of a menu item.

Moves you to the next screen.

a.If the Freedom Sequence power manager is installed in the power system, the shore breaker capac- ity on the power manager is adjusted but not the inverter/charger.

 

 

97-0019-01-01

17

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 31
Contents Model Numbers Sine Wave Inverter/ChargersPage Product Numbers Exclusion for DocumentationDocument Part Number Date and RevisionAudience About This GuidePurpose ScopeRelated Information Reference Important Safety InstructionsFire and Burn Hazard Precautions When Working With Batteries Regulatory Precautions When Preparing to ChargeViii FCC Information to the UserContents Page Page Page Materials List IntroductionKey Features Explained Key FeaturesParallel Stacking StackingSeries Stacking Generator Assist Stack ChargingBasic Protection Features Xanbus System System ComponentsProduct/Accessory Shown above Product Number/s Product/Accessory Not Shown Product Number/sSystem Components Compartment Side Cooling Fans Front Panel Controls Status LEDsIsometric View of the Front Panel and Fans Freedom SW Front and Side PanelsFreedom SW Start Up Behavior Freedom Inverter/Charger OperationTo operate in invert mode from the front panel Inverter Operation Using the Front PanelFront Panel Lights Operating Limits for Inverter Operation Operating Limits for Charger Operation Operating the Freedom SW with the SCP System Control Panel Using the Xanbus SCP10 9 8 9 Down and Up arrow buttons Func buttonEnter button Startup Screen SCP NavigationViewing the SCP Home Screens To display the Select Device menu To display the Setup menu for a deviceSoft Keys Soft Key NavigationFreedom SW System Status Screen Soft Key Navigation To view the F/W Rev. from the System Status screen Viewing the Firmware Revision NumberTo view the firmware revision number Using the STBY/ON Fault Clear Button Setting the Time and DateSystem Status Screen Reading the System Status ScreenTo view the Freedom SW Setup menu screen Reading the Freedom SW Device Setup ScreenPressed Simultaneously Device Setup Screen Status InformationLine Label FSW3012 00 Setup ButtonFreedom SW Device Setup Screen Operating States Modes Configuring the Freedom SW using the SCP SCP System Menu Map System Menu MapViewing the Select Device Menu Viewing the System Status ScreenSelecting the Freedom SW from the Select Device Menu Device Setup Menu ScreenFreedom SW Device Setup Menu Selecting and Changing a Configurable Setting To select and change a configurable settingConfigurable Settings Using Search ModeConfiguring the Freedom SW using the SCP To start equalizing the batteries, do one of the following Equalization ProcedureTo select the Basic Settings menu screen Changing Freedom SW Basic Settings915W Basic Settings Setting Defaults and RangesExamples CalculationsChanging Freedom SW Advanced Settings Advanced Settings is highlighted Freedom SW Owner’s Guide To select the Advanced Settings menu screenSelecting Advanced Settings From the Device Setup Screen Appears only when Equalize support is Enabled Menu Map of the Freedom SW Advanced Settings Inverter Settings Description Inverter Settings MenuSearch Delay Lbco Delay SettingsUsing the Low Battery Cut Out Configuring the Freedom SW using the SCPCharger Settings Menu Charger Settings Menu Description Battery Charger FunctionsSettings menu Custom Battery Settings MenuCustom Battery Settings Menu Description Freq ACIn SettingsACIn Settings Menu Description AC1 Lo VoltGenSup Amps GenSup ModeGen Support GEN Support Menu Description and ValuesaStacking Menu Description and Values a Stacking Configuration MenuTo customize the Freedom SW name Setting the Device NameIf Basic Settings appears instead of Advanced Settings on Setting the Device NumberTo set the Freedom SW device number Restore Defaults command, press Enter Resetting the Freedom SW to Default SettingsUsing the Advanced Features To restore Freedom SW default settingsThree-Stage charging Battery Charging ReferenceBattery Types Charge Algorithm StagesBulk Stage Three-Stage Battery Charging CycleFloat Stage Absorption StageTwo-Stage Charging Cycle Two-Stage Charging ProcessBattery Charging Reference Equalize Charging Equalize ChargingBattery Charging Reference General Troubleshooting Guidelines TroubleshootingMotor Loads Problem LoadsInverter Applications Resistive LoadsFault type Behavior Fault TypesFault Types And Behaviors Fault Types Troubleshooting the Freedom SW via the SCPFaults Types and Behaviors To view a warning list To view a fault listAC Output over Fault MessagesAC Output under VoltageImmediate F44 Battery OverTemperature F47 DC Under VoltageF48 DC Under Voltage FaultF49 DC Over Voltage Unreadable F57 FET1 Over TemperatureF58 FET2 Over Temperature F63 Power Board TempF70 Unique Dev# Needed Temperature F69 External Sync FailedF64 AC overload F68 Transformer OverF75 Master Inverter Lost F85 PowerBoard OverW48 DC under voltage GenSup Mode settingW69 AGS not connected Physical Specifications SpecificationsInverter Specifications Freedom SW Charger SpecificationsRegulatory Approvals All ModelsPage Inverters USA Inc Schneider Electric Solar97-0019-01-01

815-2024, 815-2012, 815-3012, 815-3024 specifications

Xantrex Technology is a leading manufacturer of advanced power electronics, providing high-quality inverter solutions that cater to diverse applications. Among its impressive portfolio, the Xantrex models 815-3024, 815-3012, 815-2012, and 815-2024 stand out for their reliability and innovative features.

The Xantrex 815-3024 is a robust 3000W inverter designed for 24V systems. Its key feature is the True Sine Wave output, which delivers clean and stable power, making it suitable for sensitive electronics and appliances. It also incorporates an advanced inverter technology that optimizes efficiency and performance. Its compact design allows for easy installation in various setups, such as RVs, boats, and off-grid systems.

Similarly, the Xantrex 815-3012 model caters to 12V applications and offers a continuous output power of 3000W. This inverter excels at providing high surge capability, helping to start up demanding loads such as refrigerators and power tools. The 815-3012 also features an LCD display, which provides real-time data on power consumption, battery voltage, and inverter status, enhancing user experience and enabling proactive management of power usage.

The Xantrex 815-2012 is a 2000W inverter specifically designed for 12V systems. It shares many technological advancements with its higher-powered counterparts, including the True Sine Wave output. This makes it an ideal choice for users seeking a reliable and efficient power source for smaller loads. Additionally, the model includes built-in protection features such as overload, short circuit, and over-temperature safety measures, ensuring longevity and safe operation.

Lastly, the Xantrex 815-2024 offers similar capabilities but is tailored for 24V systems with a power output of 2000W. It is well-suited for applications where moderate power demand exists, such as solar setups and battery-based power solutions. Its compact form factor and lightweight design make it particularly appealing for mobile and temporary installations.

All of these models feature technologies that promote energy efficiency, including automatic low voltage shutdown and smart cooling systems. They boast protective features that ensure the safety and durability of the devices connected to them. With their blend of advanced technologies, reliable performance, and user-friendly interfaces, Xantrex’s 815 Series inverters provide an excellent solution for anyone in need of dependable power conversion.