Xantrex Technology 815-3012, 815-3024 Setting the Device Name, To customize the Freedom SW name

Page 69

Freedom SW 3K2K InvChg Owners Guide.book Page 55 Wednesday, October 9, 2013 1:34 PM

Configuring the Freedom SW using the SCP

Setting the Device Name

The Dev Name setting allows you to customize the name of the Freedom SW as it is displayed on other screens and menus.

Changing the device name is not mandatory for stacking to be successful. It simply allows a user to distinguish between multiple inverter/chargers that are installed in the same system.

The characters available are:

A to Z

a to z

0 to 9

space

NOTE: Increasing the number of characters in a device name may cause other text on the same line to run off the edge of the screen. Device names should be limited to 10 characters or less.

Some examples of names are: “Master”, “Slave”, “Main”, and “Secondary”.

To customize the Freedom SW name:

1.On the device setup menu, select Advanced Settings.

If Basic Settings appears instead of Advanced Settings on the device setup menu, display Advanced Settings by pressing Enter + Up arrow + Down arrow at the same time.

2.Select the Stacking menu.

3.Select Dev Name.

4.Press Enter.

The last letter of the Freedom SW name is highlighted.

5.Begin customizing the device name.

To change the character, press the up or down arrow button. Holding down the button causes the characters to scroll more quickly.

To delete the character, press Func.

To add characters, press Enter.

6.When the correct character is shown, press Enter to select it.

7.After pressing Enter to select the last character of your customized device name, press Enter again to return to the menu.

 

 

97-0019-01-01

55

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 69
Contents Model Numbers Sine Wave Inverter/ChargersPage Document Part Number Exclusion for DocumentationDate and Revision Product NumbersPurpose About This GuideScope AudienceRelated Information Reference Important Safety InstructionsFire and Burn Hazard Precautions When Working With Batteries Regulatory Precautions When Preparing to ChargeViii FCC Information to the UserContents Page Page Page Materials List IntroductionKey Features Explained Key FeaturesStacking Parallel StackingSeries Stacking Generator Assist Stack ChargingBasic Protection Features Xanbus System System ComponentsProduct/Accessory Not Shown Product Number/s Product/Accessory Shown above Product Number/sSystem Components Compartment Side Cooling Fans Front Panel Controls Status LEDsIsometric View of the Front Panel and Fans Freedom SW Front and Side PanelsFreedom SW Start Up Behavior Freedom Inverter/Charger OperationInverter Operation Using the Front Panel To operate in invert mode from the front panelFront Panel Lights Operating Limits for Inverter Operation Operating Limits for Charger Operation Operating the Freedom SW with the SCP Using the Xanbus SCP System Control Panel10 9 8 Func button 9 Down and Up arrow buttonsEnter button SCP Navigation Startup ScreenViewing the SCP Home Screens To display the Select Device menu To display the Setup menu for a deviceSoft Keys Soft Key NavigationFreedom SW System Status Screen Soft Key Navigation Viewing the Firmware Revision Number To view the F/W Rev. from the System Status screenTo view the firmware revision number Using the STBY/ON Fault Clear Button Setting the Time and DateSystem Status Screen Reading the System Status ScreenTo view the Freedom SW Setup menu screen Reading the Freedom SW Device Setup ScreenLine Label FSW3012 00 Setup Device Setup Screen Status InformationButton Pressed SimultaneouslyFreedom SW Device Setup Screen Operating States Modes Configuring the Freedom SW using the SCP SCP System Menu Map System Menu MapViewing the Select Device Menu Viewing the System Status ScreenSelecting the Freedom SW from the Select Device Menu Device Setup Menu ScreenFreedom SW Device Setup Menu Selecting and Changing a Configurable Setting To select and change a configurable settingConfigurable Settings Using Search ModeConfiguring the Freedom SW using the SCP To start equalizing the batteries, do one of the following Equalization ProcedureTo select the Basic Settings menu screen Changing Freedom SW Basic Settings915W Basic Settings Setting Defaults and RangesExamples CalculationsChanging Freedom SW Advanced Settings Advanced Settings is highlighted Freedom SW Owner’s Guide To select the Advanced Settings menu screenSelecting Advanced Settings From the Device Setup Screen Appears only when Equalize support is Enabled Menu Map of the Freedom SW Advanced Settings Inverter Settings Description Inverter Settings MenuUsing the Low Battery Cut Out Lbco Delay SettingsConfiguring the Freedom SW using the SCP Search DelayCharger Settings Menu Charger Settings Menu Description Battery Charger FunctionsSettings menu Custom Battery Settings MenuCustom Battery Settings Menu Description ACIn Settings Menu Description ACIn SettingsAC1 Lo Volt FreqGen Support GenSup ModeGEN Support Menu Description and Valuesa GenSup AmpsStacking Menu Description and Values a Stacking Configuration MenuTo customize the Freedom SW name Setting the Device NameSetting the Device Number If Basic Settings appears instead of Advanced Settings onTo set the Freedom SW device number Using the Advanced Features Resetting the Freedom SW to Default SettingsTo restore Freedom SW default settings Restore Defaults command, press EnterBattery Types Battery Charging ReferenceCharge Algorithm Stages Three-Stage chargingBulk Stage Three-Stage Battery Charging CycleFloat Stage Absorption StageTwo-Stage Charging Cycle Two-Stage Charging ProcessBattery Charging Reference Equalize Charging Equalize ChargingBattery Charging Reference General Troubleshooting Guidelines TroubleshootingInverter Applications Problem LoadsResistive Loads Motor LoadsFault Types Fault type BehaviorFault Types And Behaviors Troubleshooting the Freedom SW via the SCP Fault TypesFaults Types and Behaviors To view a warning list To view a fault listAC Output under Fault MessagesVoltage AC Output overTemperature F44 Battery OverF47 DC Under Voltage ImmediateFault F48 DC Under VoltageF49 DC Over Voltage F58 FET2 Over Temperature F57 FET1 Over TemperatureF63 Power Board Temp UnreadableF64 AC overload Temperature F69 External Sync FailedF68 Transformer Over F70 Unique Dev# NeededF75 Master Inverter Lost F85 PowerBoard OverGenSup Mode setting W48 DC under voltageW69 AGS not connected Physical Specifications SpecificationsInverter Specifications Freedom SW Charger SpecificationsRegulatory Approvals All ModelsPage Schneider Electric Solar Inverters USA Inc97-0019-01-01

815-2024, 815-2012, 815-3012, 815-3024 specifications

Xantrex Technology is a leading manufacturer of advanced power electronics, providing high-quality inverter solutions that cater to diverse applications. Among its impressive portfolio, the Xantrex models 815-3024, 815-3012, 815-2012, and 815-2024 stand out for their reliability and innovative features.

The Xantrex 815-3024 is a robust 3000W inverter designed for 24V systems. Its key feature is the True Sine Wave output, which delivers clean and stable power, making it suitable for sensitive electronics and appliances. It also incorporates an advanced inverter technology that optimizes efficiency and performance. Its compact design allows for easy installation in various setups, such as RVs, boats, and off-grid systems.

Similarly, the Xantrex 815-3012 model caters to 12V applications and offers a continuous output power of 3000W. This inverter excels at providing high surge capability, helping to start up demanding loads such as refrigerators and power tools. The 815-3012 also features an LCD display, which provides real-time data on power consumption, battery voltage, and inverter status, enhancing user experience and enabling proactive management of power usage.

The Xantrex 815-2012 is a 2000W inverter specifically designed for 12V systems. It shares many technological advancements with its higher-powered counterparts, including the True Sine Wave output. This makes it an ideal choice for users seeking a reliable and efficient power source for smaller loads. Additionally, the model includes built-in protection features such as overload, short circuit, and over-temperature safety measures, ensuring longevity and safe operation.

Lastly, the Xantrex 815-2024 offers similar capabilities but is tailored for 24V systems with a power output of 2000W. It is well-suited for applications where moderate power demand exists, such as solar setups and battery-based power solutions. Its compact form factor and lightweight design make it particularly appealing for mobile and temporary installations.

All of these models feature technologies that promote energy efficiency, including automatic low voltage shutdown and smart cooling systems. They boast protective features that ensure the safety and durability of the devices connected to them. With their blend of advanced technologies, reliable performance, and user-friendly interfaces, Xantrex’s 815 Series inverters provide an excellent solution for anyone in need of dependable power conversion.