Xantrex Technology 815-3024, 815-3012, 815-2012, 815-2024 manual

Page 12

Freedom SW 3K2K InvChg Owners Guide.book Page ii Wednesday, October 9, 2013 1:34 PM

SCP Navigation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Startup Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Viewing the SCP Home Screens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Soft Key Navigation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Viewing the Firmware Revision Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Setting the Time and Date . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Using the STBY/ON Fault Clear Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Reading the System Status Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Reading the Freedom SW Device Setup Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

Configuring the Freedom SW using the SCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

System Menu Map

29

Viewing the System Status Screen

30

Viewing the Select Device Menu

30

Selecting the Freedom SW from the Select Device Menu

31

Changing Configurable Settings From The Device Setup Menu Screen

32

Using Search Mode

34

Equalization Procedure

36

Changing Freedom SW Basic Settings

37

Charger settings in a Dual Freedom SW configuration

40

Calculations

40

Examples

40

Changing Freedom SW Advanced Settings

41

Inverter Settings Menu

46

Using the Low Battery Cut Out and LBCO Delay Settings

47

Charger Settings Menu

48

Battery Charger Functions

49

Custom Battery Settings Menu

50

Image 12
Contents Sine Wave Inverter/Chargers Model NumbersPage Exclusion for Documentation Document Part NumberDate and Revision Product NumbersAbout This Guide PurposeScope AudienceRelated Information Important Safety Instructions ReferenceFire and Burn Hazard Precautions When Working With Batteries Precautions When Preparing to Charge RegulatoryFCC Information to the User ViiiContents Page Page Page Introduction Materials ListKey Features Key Features ExplainedStacking Parallel StackingSeries Stacking Stack Charging Generator AssistBasic Protection Features System Components Xanbus SystemProduct/Accessory Not Shown Product Number/s Product/Accessory Shown above Product Number/sSystem Components Front Panel Controls Status LEDs Compartment Side Cooling FansFreedom SW Front and Side Panels Isometric View of the Front Panel and FansFreedom SW Freedom Inverter/Charger Operation Start Up BehaviorInverter Operation Using the Front Panel To operate in invert mode from the front panelFront Panel Lights Operating Limits for Inverter Operation Operating Limits for Charger Operation Operating the Freedom SW with the SCP Using the Xanbus SCP System Control Panel10 9 8 Func button 9 Down and Up arrow buttonsEnter button SCP Navigation Startup ScreenViewing the SCP Home Screens To display the Setup menu for a device To display the Select Device menuSoft Key Navigation Soft KeysFreedom SW System Status Screen Soft Key Navigation Viewing the Firmware Revision Number To view the F/W Rev. from the System Status screenTo view the firmware revision number Setting the Time and Date Using the STBY/ON Fault Clear ButtonReading the System Status Screen System Status ScreenReading the Freedom SW Device Setup Screen To view the Freedom SW Setup menu screenDevice Setup Screen Status Information Line Label FSW3012 00 SetupButton Pressed SimultaneouslyFreedom SW Device Setup Screen Operating States Modes Configuring the Freedom SW using the SCP System Menu Map SCP System Menu MapViewing the System Status Screen Viewing the Select Device MenuDevice Setup Menu Screen Selecting the Freedom SW from the Select Device MenuFreedom SW Device Setup Menu To select and change a configurable setting Selecting and Changing a Configurable SettingUsing Search Mode Configurable SettingsConfiguring the Freedom SW using the SCP Equalization Procedure To start equalizing the batteries, do one of the followingChanging Freedom SW Basic Settings To select the Basic Settings menu screen915W Setting Defaults and Ranges Basic SettingsCalculations ExamplesChanging Freedom SW Advanced Settings To select the Advanced Settings menu screen Advanced Settings is highlighted Freedom SW Owner’s GuideSelecting Advanced Settings From the Device Setup Screen Appears only when Equalize support is Enabled Menu Map of the Freedom SW Advanced Settings Inverter Settings Menu Inverter Settings DescriptionLbco Delay Settings Using the Low Battery Cut OutConfiguring the Freedom SW using the SCP Search DelayCharger Settings Menu Battery Charger Functions Charger Settings Menu DescriptionCustom Battery Settings Menu Settings menuCustom Battery Settings Menu Description ACIn Settings ACIn Settings Menu DescriptionAC1 Lo Volt FreqGenSup Mode Gen SupportGEN Support Menu Description and Valuesa GenSup AmpsStacking Configuration Menu Stacking Menu Description and Values aSetting the Device Name To customize the Freedom SW nameSetting the Device Number If Basic Settings appears instead of Advanced Settings onTo set the Freedom SW device number Resetting the Freedom SW to Default Settings Using the Advanced FeaturesTo restore Freedom SW default settings Restore Defaults command, press EnterBattery Charging Reference Battery TypesCharge Algorithm Stages Three-Stage chargingThree-Stage Battery Charging Cycle Bulk StageAbsorption Stage Float StageTwo-Stage Charging Process Two-Stage Charging CycleBattery Charging Reference Equalize Charging Equalize ChargingBattery Charging Reference Troubleshooting General Troubleshooting GuidelinesProblem Loads Inverter ApplicationsResistive Loads Motor LoadsFault Types Fault type BehaviorFault Types And Behaviors Troubleshooting the Freedom SW via the SCP Fault TypesFaults Types and Behaviors To view a fault list To view a warning listFault Messages AC Output underVoltage AC Output overF44 Battery Over TemperatureF47 DC Under Voltage ImmediateFault F48 DC Under VoltageF49 DC Over Voltage F57 FET1 Over Temperature F58 FET2 Over TemperatureF63 Power Board Temp UnreadableTemperature F69 External Sync Failed F64 AC overloadF68 Transformer Over F70 Unique Dev# NeededF85 PowerBoard Over F75 Master Inverter LostGenSup Mode setting W48 DC under voltageW69 AGS not connected Specifications Physical SpecificationsInverter Specifications Charger Specifications Freedom SWAll Models Regulatory ApprovalsPage Schneider Electric Solar Inverters USA Inc97-0019-01-01

815-2024, 815-2012, 815-3012, 815-3024 specifications

Xantrex Technology is a leading manufacturer of advanced power electronics, providing high-quality inverter solutions that cater to diverse applications. Among its impressive portfolio, the Xantrex models 815-3024, 815-3012, 815-2012, and 815-2024 stand out for their reliability and innovative features.

The Xantrex 815-3024 is a robust 3000W inverter designed for 24V systems. Its key feature is the True Sine Wave output, which delivers clean and stable power, making it suitable for sensitive electronics and appliances. It also incorporates an advanced inverter technology that optimizes efficiency and performance. Its compact design allows for easy installation in various setups, such as RVs, boats, and off-grid systems.

Similarly, the Xantrex 815-3012 model caters to 12V applications and offers a continuous output power of 3000W. This inverter excels at providing high surge capability, helping to start up demanding loads such as refrigerators and power tools. The 815-3012 also features an LCD display, which provides real-time data on power consumption, battery voltage, and inverter status, enhancing user experience and enabling proactive management of power usage.

The Xantrex 815-2012 is a 2000W inverter specifically designed for 12V systems. It shares many technological advancements with its higher-powered counterparts, including the True Sine Wave output. This makes it an ideal choice for users seeking a reliable and efficient power source for smaller loads. Additionally, the model includes built-in protection features such as overload, short circuit, and over-temperature safety measures, ensuring longevity and safe operation.

Lastly, the Xantrex 815-2024 offers similar capabilities but is tailored for 24V systems with a power output of 2000W. It is well-suited for applications where moderate power demand exists, such as solar setups and battery-based power solutions. Its compact form factor and lightweight design make it particularly appealing for mobile and temporary installations.

All of these models feature technologies that promote energy efficiency, including automatic low voltage shutdown and smart cooling systems. They boast protective features that ensure the safety and durability of the devices connected to them. With their blend of advanced technologies, reliable performance, and user-friendly interfaces, Xantrex’s 815 Series inverters provide an excellent solution for anyone in need of dependable power conversion.