Xantrex Technology 815-2024, 815-3024, 815-3012 manual Resetting the Freedom SW to Default Settings

Page 71

Freedom SW 3K2K InvChg Owners Guide.book Page 57 Wednesday, October 9, 2013 1:34 PM

Configuring the Freedom SW using the SCP

Resetting the Freedom SW to

Default Settings

The Restore Defaults command returns the Freedom SW to factory default settings. After using the Restore Defaults command, the Freedom SW is no longer configured for the power system.

To restore Freedom SW default settings:

1.On the Advanced Setup menu, select Restore Defaults. Warning W252 appears, asking to confirm the command.

2.To cancel the command, press Func. To continue with the

Restore Defaults command, press Enter.

IMPORTANT: If a warning is already active in the system, selecting Restore Defaults brings up the Warnings list, with warning W252 at the top. Press Enter to view W252 and continue with the restore defaults process.

EQUIPMENT DAMAGE

Do not restore defaults while the Freedom SW is operating. De-energize the power system and disconnect the Freedom SW AC input before restoring defaults. Reconfigure the Freedom SW before reconnecting the AC input and re-energizing the power system.

Failure to follow these instructions can damage the unit and/or damage other equipment.

Using the Advanced Features

FSW3012 00: Adv Features

NoLoadVD

[Disabled]

[*Disabled] [Enabled]

Follow procedures on “To select and change a configurable setting:” on page 33 to change the settings.

Figure 31 Adv Features Menu Screen

Table 18 Adv Features Description and Valuesa

Item

Description

Default

Range

 

 

 

 

NoLoadVD

When enabled, power save

Disabled

Disabled,

 

mode can reduce tare loss

 

Enabled

 

from the battery by reducing

 

 

 

output from 120 volts to 110

 

 

 

volts when the loads are less

 

 

 

than 100 watts. When the

 

 

 

Freedom SW detects loads

 

 

 

higher than 100 watts, it

 

 

 

produces the full 120 volts.

 

 

 

 

 

 

a. Applies to all Freedom SW models.

97-0019-01-01

57

Image 71
Contents Model Numbers Sine Wave Inverter/ChargersPage Product Numbers Exclusion for DocumentationDocument Part Number Date and RevisionAudience About This GuidePurpose ScopeRelated Information Reference Important Safety InstructionsFire and Burn Hazard Precautions When Working With Batteries Regulatory Precautions When Preparing to ChargeViii FCC Information to the UserContents Page Page Page Materials List IntroductionKey Features Explained Key FeaturesSeries Stacking StackingParallel Stacking Generator Assist Stack ChargingBasic Protection Features Xanbus System System ComponentsSystem Components Product/Accessory Not Shown Product Number/sProduct/Accessory Shown above Product Number/s Compartment Side Cooling Fans Front Panel Controls Status LEDsIsometric View of the Front Panel and Fans Freedom SW Front and Side PanelsFreedom SW Start Up Behavior Freedom Inverter/Charger OperationFront Panel Lights Inverter Operation Using the Front PanelTo operate in invert mode from the front panel Operating Limits for Inverter Operation Operating Limits for Charger Operation Operating the Freedom SW with the SCP 10 9 8 Using the Xanbus SCPSystem Control Panel Enter button Func button9 Down and Up arrow buttons Viewing the SCP Home Screens SCP NavigationStartup Screen To display the Select Device menu To display the Setup menu for a deviceSoft Keys Soft Key NavigationFreedom SW System Status Screen Soft Key Navigation To view the firmware revision number Viewing the Firmware Revision NumberTo view the F/W Rev. from the System Status screen Using the STBY/ON Fault Clear Button Setting the Time and DateSystem Status Screen Reading the System Status ScreenTo view the Freedom SW Setup menu screen Reading the Freedom SW Device Setup ScreenPressed Simultaneously Device Setup Screen Status InformationLine Label FSW3012 00 Setup ButtonFreedom SW Device Setup Screen Operating States Modes Configuring the Freedom SW using the SCP SCP System Menu Map System Menu MapViewing the Select Device Menu Viewing the System Status ScreenSelecting the Freedom SW from the Select Device Menu Device Setup Menu ScreenFreedom SW Device Setup Menu Selecting and Changing a Configurable Setting To select and change a configurable settingConfigurable Settings Using Search ModeConfiguring the Freedom SW using the SCP To start equalizing the batteries, do one of the following Equalization ProcedureTo select the Basic Settings menu screen Changing Freedom SW Basic Settings915W Basic Settings Setting Defaults and RangesExamples CalculationsChanging Freedom SW Advanced Settings Advanced Settings is highlighted Freedom SW Owner’s Guide To select the Advanced Settings menu screenSelecting Advanced Settings From the Device Setup Screen Appears only when Equalize support is Enabled Menu Map of the Freedom SW Advanced Settings Inverter Settings Description Inverter Settings MenuSearch Delay Lbco Delay SettingsUsing the Low Battery Cut Out Configuring the Freedom SW using the SCPCharger Settings Menu Charger Settings Menu Description Battery Charger FunctionsSettings menu Custom Battery Settings MenuCustom Battery Settings Menu Description Freq ACIn SettingsACIn Settings Menu Description AC1 Lo VoltGenSup Amps GenSup ModeGen Support GEN Support Menu Description and ValuesaStacking Menu Description and Values a Stacking Configuration MenuTo customize the Freedom SW name Setting the Device NameTo set the Freedom SW device number Setting the Device NumberIf Basic Settings appears instead of Advanced Settings on Restore Defaults command, press Enter Resetting the Freedom SW to Default SettingsUsing the Advanced Features To restore Freedom SW default settingsThree-Stage charging Battery Charging ReferenceBattery Types Charge Algorithm StagesBulk Stage Three-Stage Battery Charging CycleFloat Stage Absorption StageTwo-Stage Charging Cycle Two-Stage Charging ProcessBattery Charging Reference Equalize Charging Equalize ChargingBattery Charging Reference General Troubleshooting Guidelines TroubleshootingMotor Loads Problem LoadsInverter Applications Resistive LoadsFault Types And Behaviors Fault TypesFault type Behavior Faults Types and Behaviors Troubleshooting the Freedom SW via the SCPFault Types To view a warning list To view a fault listAC Output over Fault MessagesAC Output under VoltageImmediate F44 Battery OverTemperature F47 DC Under VoltageF49 DC Over Voltage FaultF48 DC Under Voltage Unreadable F57 FET1 Over TemperatureF58 FET2 Over Temperature F63 Power Board TempF70 Unique Dev# Needed Temperature F69 External Sync FailedF64 AC overload F68 Transformer OverF75 Master Inverter Lost F85 PowerBoard OverW69 AGS not connected GenSup Mode settingW48 DC under voltage Physical Specifications SpecificationsInverter Specifications Freedom SW Charger SpecificationsRegulatory Approvals All ModelsPage 97-0019-01-01 Schneider Electric SolarInverters USA Inc

815-2024, 815-2012, 815-3012, 815-3024 specifications

Xantrex Technology is a leading manufacturer of advanced power electronics, providing high-quality inverter solutions that cater to diverse applications. Among its impressive portfolio, the Xantrex models 815-3024, 815-3012, 815-2012, and 815-2024 stand out for their reliability and innovative features.

The Xantrex 815-3024 is a robust 3000W inverter designed for 24V systems. Its key feature is the True Sine Wave output, which delivers clean and stable power, making it suitable for sensitive electronics and appliances. It also incorporates an advanced inverter technology that optimizes efficiency and performance. Its compact design allows for easy installation in various setups, such as RVs, boats, and off-grid systems.

Similarly, the Xantrex 815-3012 model caters to 12V applications and offers a continuous output power of 3000W. This inverter excels at providing high surge capability, helping to start up demanding loads such as refrigerators and power tools. The 815-3012 also features an LCD display, which provides real-time data on power consumption, battery voltage, and inverter status, enhancing user experience and enabling proactive management of power usage.

The Xantrex 815-2012 is a 2000W inverter specifically designed for 12V systems. It shares many technological advancements with its higher-powered counterparts, including the True Sine Wave output. This makes it an ideal choice for users seeking a reliable and efficient power source for smaller loads. Additionally, the model includes built-in protection features such as overload, short circuit, and over-temperature safety measures, ensuring longevity and safe operation.

Lastly, the Xantrex 815-2024 offers similar capabilities but is tailored for 24V systems with a power output of 2000W. It is well-suited for applications where moderate power demand exists, such as solar setups and battery-based power solutions. Its compact form factor and lightweight design make it particularly appealing for mobile and temporary installations.

All of these models feature technologies that promote energy efficiency, including automatic low voltage shutdown and smart cooling systems. They boast protective features that ensure the safety and durability of the devices connected to them. With their blend of advanced technologies, reliable performance, and user-friendly interfaces, Xantrex’s 815 Series inverters provide an excellent solution for anyone in need of dependable power conversion.