Xantrex Technology 815-2012, 815-3024, 815-3012 F48 DC Under Voltage, Fault, F49 DC Over Voltage

Page 86

Freedom SW 3K2K InvChg Owners Guide.book Page 72 Wednesday, October 9, 2013 1:34 PM

Troubleshooting

Table 4 Fault Messages

Fault

 

 

 

 

Number

Message

Fault Type

Cause

Solution

 

 

 

 

 

F48

DC Under Voltage

Automatic

Voltage at the DC input

Check for the correct battery voltage at the

 

(Fault)

 

terminals is below the Low

inverter's DC input terminals.

 

 

 

Battery Cut Out (LBCO)

Check for external DC loads on the

 

 

 

setting for 10 seconds.

batteries.

 

 

 

 

Check condition of batteries and recharge

 

 

 

 

if necessary.

 

 

 

 

Reduce the Low Battery Cut Out (LBCO)

 

 

 

 

setting.

 

 

 

 

Battery bank capacity may be inadequate

 

 

 

 

for the loads in the system.

 

 

 

 

 

F49

DC Over Voltage

Automatic

Voltage at the DC input

Clear the fault and attempt restart. Ensure

 

 

 

terminals is above the High

battery voltage is 10–16 VDC at Freedom

 

 

 

Battery Cut Out Setting

SW terminals. Check all other charging

 

 

 

 

source outputs, battery cables.

 

 

 

 

 

 

 

72

 

 

Freedom SW Owner’s Guide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 86
Contents Sine Wave Inverter/Chargers Model NumbersPage Date and Revision Exclusion for DocumentationDocument Part Number Product NumbersScope About This GuidePurpose AudienceRelated Information Important Safety Instructions ReferenceFire and Burn Hazard Precautions When Working With Batteries Precautions When Preparing to Charge RegulatoryFCC Information to the User ViiiContents Page Page Page Introduction Materials ListKey Features Key Features ExplainedSeries Stacking StackingParallel Stacking Stack Charging Generator AssistBasic Protection Features System Components Xanbus SystemSystem Components Product/Accessory Not Shown Product Number/sProduct/Accessory Shown above Product Number/s Front Panel Controls Status LEDs Compartment Side Cooling FansFreedom SW Front and Side Panels Isometric View of the Front Panel and FansFreedom SW Freedom Inverter/Charger Operation Start Up BehaviorFront Panel Lights Inverter Operation Using the Front PanelTo operate in invert mode from the front panel Operating Limits for Inverter Operation Operating Limits for Charger Operation Operating the Freedom SW with the SCP 10 9 8 Using the Xanbus SCPSystem Control Panel Enter button Func button9 Down and Up arrow buttons Viewing the SCP Home Screens SCP NavigationStartup Screen To display the Setup menu for a device To display the Select Device menuSoft Key Navigation Soft KeysFreedom SW System Status Screen Soft Key Navigation To view the firmware revision number Viewing the Firmware Revision NumberTo view the F/W Rev. from the System Status screen Setting the Time and Date Using the STBY/ON Fault Clear ButtonReading the System Status Screen System Status ScreenReading the Freedom SW Device Setup Screen To view the Freedom SW Setup menu screenButton Device Setup Screen Status InformationLine Label FSW3012 00 Setup Pressed SimultaneouslyFreedom SW Device Setup Screen Operating States Modes Configuring the Freedom SW using the SCP System Menu Map SCP System Menu MapViewing the System Status Screen Viewing the Select Device MenuDevice Setup Menu Screen Selecting the Freedom SW from the Select Device MenuFreedom SW Device Setup Menu To select and change a configurable setting Selecting and Changing a Configurable SettingUsing Search Mode Configurable SettingsConfiguring the Freedom SW using the SCP Equalization Procedure To start equalizing the batteries, do one of the followingChanging Freedom SW Basic Settings To select the Basic Settings menu screen915W Setting Defaults and Ranges Basic SettingsCalculations ExamplesChanging Freedom SW Advanced Settings To select the Advanced Settings menu screen Advanced Settings is highlighted Freedom SW Owner’s GuideSelecting Advanced Settings From the Device Setup Screen Appears only when Equalize support is Enabled Menu Map of the Freedom SW Advanced Settings Inverter Settings Menu Inverter Settings DescriptionConfiguring the Freedom SW using the SCP Lbco Delay SettingsUsing the Low Battery Cut Out Search DelayCharger Settings Menu Battery Charger Functions Charger Settings Menu DescriptionCustom Battery Settings Menu Settings menuCustom Battery Settings Menu Description AC1 Lo Volt ACIn SettingsACIn Settings Menu Description FreqGEN Support Menu Description and Valuesa GenSup ModeGen Support GenSup AmpsStacking Configuration Menu Stacking Menu Description and Values aSetting the Device Name To customize the Freedom SW nameTo set the Freedom SW device number Setting the Device NumberIf Basic Settings appears instead of Advanced Settings on To restore Freedom SW default settings Resetting the Freedom SW to Default SettingsUsing the Advanced Features Restore Defaults command, press EnterCharge Algorithm Stages Battery Charging ReferenceBattery Types Three-Stage chargingThree-Stage Battery Charging Cycle Bulk StageAbsorption Stage Float StageTwo-Stage Charging Process Two-Stage Charging CycleBattery Charging Reference Equalize Charging Equalize ChargingBattery Charging Reference Troubleshooting General Troubleshooting GuidelinesResistive Loads Problem LoadsInverter Applications Motor LoadsFault Types And Behaviors Fault TypesFault type Behavior Faults Types and Behaviors Troubleshooting the Freedom SW via the SCPFault Types To view a fault list To view a warning listVoltage Fault MessagesAC Output under AC Output overF47 DC Under Voltage F44 Battery OverTemperature ImmediateF49 DC Over Voltage FaultF48 DC Under Voltage F63 Power Board Temp F57 FET1 Over TemperatureF58 FET2 Over Temperature UnreadableF68 Transformer Over Temperature F69 External Sync FailedF64 AC overload F70 Unique Dev# NeededF85 PowerBoard Over F75 Master Inverter LostW69 AGS not connected GenSup Mode settingW48 DC under voltage Specifications Physical SpecificationsInverter Specifications Charger Specifications Freedom SWAll Models Regulatory ApprovalsPage 97-0019-01-01 Schneider Electric SolarInverters USA Inc

815-2024, 815-2012, 815-3012, 815-3024 specifications

Xantrex Technology is a leading manufacturer of advanced power electronics, providing high-quality inverter solutions that cater to diverse applications. Among its impressive portfolio, the Xantrex models 815-3024, 815-3012, 815-2012, and 815-2024 stand out for their reliability and innovative features.

The Xantrex 815-3024 is a robust 3000W inverter designed for 24V systems. Its key feature is the True Sine Wave output, which delivers clean and stable power, making it suitable for sensitive electronics and appliances. It also incorporates an advanced inverter technology that optimizes efficiency and performance. Its compact design allows for easy installation in various setups, such as RVs, boats, and off-grid systems.

Similarly, the Xantrex 815-3012 model caters to 12V applications and offers a continuous output power of 3000W. This inverter excels at providing high surge capability, helping to start up demanding loads such as refrigerators and power tools. The 815-3012 also features an LCD display, which provides real-time data on power consumption, battery voltage, and inverter status, enhancing user experience and enabling proactive management of power usage.

The Xantrex 815-2012 is a 2000W inverter specifically designed for 12V systems. It shares many technological advancements with its higher-powered counterparts, including the True Sine Wave output. This makes it an ideal choice for users seeking a reliable and efficient power source for smaller loads. Additionally, the model includes built-in protection features such as overload, short circuit, and over-temperature safety measures, ensuring longevity and safe operation.

Lastly, the Xantrex 815-2024 offers similar capabilities but is tailored for 24V systems with a power output of 2000W. It is well-suited for applications where moderate power demand exists, such as solar setups and battery-based power solutions. Its compact form factor and lightweight design make it particularly appealing for mobile and temporary installations.

All of these models feature technologies that promote energy efficiency, including automatic low voltage shutdown and smart cooling systems. They boast protective features that ensure the safety and durability of the devices connected to them. With their blend of advanced technologies, reliable performance, and user-friendly interfaces, Xantrex’s 815 Series inverters provide an excellent solution for anyone in need of dependable power conversion.