HP book XE2 manual Post Terminal-Error Beep Codes, Post Messages, Post Description

Models: book XE2

1 85
Download 85 pages 4.99 Kb
Page 59
Image 59

Table 3-4. POST Terminal-Error Beep Codes

Beep Codes

1

1-2

1-2-2-3

1-3-1-1

1-3-1-3

1-3-4-1

1-3-4-3

1-4-1-1

2-1-2-3

2-2-3-1

POST Description

One short beep before boot

Search for option ROMs. One long, two short beeps on checksum failure

BIOS ROM checksum

Test DRAM refresh

Test 8742 Keyboard Controller

RAM failure on address line xxxx

RAM failure on data bits xxxx of low byte of memory bus

RAM failure on data bits xxxx of high byte of memory bus

Check ROM copyright notice

Test for unexpected interrupts

The following table lists POST messages and explanations for reported problems. If the system fails after you make changes in BIOS Setup, reset the computer, enter BIOS Setup, and install the defaults or correct the error.

Message

0200 Failure Fixed Disk

Table 3-5. POST Messages

Description

Fixed disk is not working or not configured properly. Check to see if fixed disk is attached properly. Run Setup. Find out if the fixed-disk type is correctly identified.

0210 Stuck key

Stuck key on keyboard.

0211 Keyboard error

Keyboard not working.

0212 Keyboard Controller Failed

Keyboard controller failed test. May require replacing keyboard controller.

0213 Keyboard locked - Unlock key switch

Unlock the system to proceed.

0220 Monitor type does not match CMOS - Run SETUP

Monitor type not correctly identified in Setup

0230 Shadow Ram Failed at offset: nnnn

Shadow RAM failed at offset nnnn of the 64k block at which the error was detected.

0231 System RAM Failed at offset: nnnn

System RAM failed at offset nnnn of in the 64k block at which the error was detected.

0232 Extended RAM Failed at offset: nnnn

Extended memory not working or not configured properly at offset nnnn.

Update to the latest BIOS version 2.xx. (Service note 4100-06.)

0250 System battery is dead - Replace and run SETUP

The CMOS clock battery indicator shows the battery is dead. Connect the AC adapter for at least 24 hours, replace the motherboard.

0251 System CMOS checksum bad - Default configuration used

System CMOS has been corrupted or modified incorrectly, perhaps by an application program that changes data stored in CMOS. The BIOS installed Default Setup Values. If you do not want these values, enter Setup and enter your own values. If the error persists, check the system battery. Connect the AC adapter for at least 24 hours, replace the motherboard.

0260 System timer error

The timer test failed. Requires repair of system board.

0270 Real time clock error

Real-time clock fails BIOS test. May require board repair.

0280 Previous boot incomplete - Default configuration used

Previous POST did not complete successfully. POST loads default values and offers to run Setup. If the failure was caused by incorrect values and they are not corrected, the next boot will likely fail. This error is cleared the next time the system is booted.

0281 Memory Size found by POST differed from CMOS

Memory size found by POST differed from CMOS.

HP OmniBook XE2

Troubleshooting and Diagnostics 3-17

Page 59
Image 59
HP book XE2 manual Post Terminal-Error Beep Codes, Post Messages, Post Description