Xantrex Technology 815-3012, 815-3024, 815-2012, 815-2024 To display the Setup menu for a device

Page 33

Freedom SW 3K2K InvChg Owners Guide.book Page 19 Wednesday, October 9, 2013 1:34 PM

Operating the Freedom SW with the SCP

Select Device Screen As mentioned, this screen appears when the Enter button is pressed from the System Status screen. It lists all Xanbus-enabled devices including options to select System Settings and Clock.

To display the Setup menu for a device:

Highlight the device name on the Select Device menu screen and

press Enter.

-Or-

From the device Home screen, press Enter.

AC In/Charge

System Status

 

 

STBY/ON

Inverter On

Battery 12.1V

-257A

84”F

Fault Clear

Low Battery

BatLev

 

Invert

 

Load

120V

 

12A

 

Fault

AC In

0V

 

0A

 

menu

EnInv

EnChg

Shr

 

 

 

 

Enter

 

 

Func

 

Xanbus System Control Panel

FGA: 809 -092 1

Press Enter button to go to the

Select Device menu screen.

Select Device

System Settings FSW3012 00 XAGS 00

XSCP

AC In/Charge

FSW3012 00: Setup

 

STBY/ON

 

 

Inverter On

 

 

 

 

Mode

 

Invert

Fault Clear

Low Battery

Battery

13.4V

0.0A

N/A

 

Load

115W

120V

12A

 

 

 

Fault

AC In

120V

15A

60Hz

 

 

Enter

 

 

Func

 

FSW3012 00: Setup

Mode

 

Invert

Battery

11.8V

-88.0A

N/A

Load

900W

120V

7A

AC In

0V

0A

0Hz

Figure 8 Freedom SW Select Device Screen

Xanbus System Control Panel (SCP)

FGA: 809 -092 1

To display the Select Device menu:

While viewing the System Status screen, press Enter.

Figure 9 Freedom SW Device Screen

Device Setup Screen The Device Setup screen is shown when a Xanbus- enabled component is selected from the Select Device screen. For example, below is an example of a Device screen for the Freedom SW 3012 inverter/ charger. Device Setup menus display status information and changeable settings. Changeable settings are identified by the square brackets [ ] around values in the right-hand column.

 

 

97-0019-01-01

19

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 33
Contents Model Numbers Sine Wave Inverter/ChargersPage Document Part Number Exclusion for DocumentationDate and Revision Product NumbersPurpose About This GuideScope AudienceRelated Information Reference Important Safety InstructionsFire and Burn Hazard Precautions When Working With Batteries Regulatory Precautions When Preparing to ChargeViii FCC Information to the UserContents Page Page Page Materials List IntroductionKey Features Explained Key FeaturesStacking Parallel StackingSeries Stacking Generator Assist Stack ChargingBasic Protection Features Xanbus System System ComponentsProduct/Accessory Not Shown Product Number/s Product/Accessory Shown above Product Number/sSystem Components Compartment Side Cooling Fans Front Panel Controls Status LEDsIsometric View of the Front Panel and Fans Freedom SW Front and Side PanelsFreedom SW Start Up Behavior Freedom Inverter/Charger OperationInverter Operation Using the Front Panel To operate in invert mode from the front panelFront Panel Lights Operating Limits for Inverter Operation Operating Limits for Charger Operation Operating the Freedom SW with the SCP Using the Xanbus SCP System Control Panel10 9 8 Func button 9 Down and Up arrow buttonsEnter button SCP Navigation Startup ScreenViewing the SCP Home Screens To display the Select Device menu To display the Setup menu for a deviceSoft Keys Soft Key NavigationFreedom SW System Status Screen Soft Key Navigation Viewing the Firmware Revision Number To view the F/W Rev. from the System Status screenTo view the firmware revision number Using the STBY/ON Fault Clear Button Setting the Time and DateSystem Status Screen Reading the System Status ScreenTo view the Freedom SW Setup menu screen Reading the Freedom SW Device Setup ScreenLine Label FSW3012 00 Setup Device Setup Screen Status InformationButton Pressed SimultaneouslyFreedom SW Device Setup Screen Operating States Modes Configuring the Freedom SW using the SCP SCP System Menu Map System Menu MapViewing the Select Device Menu Viewing the System Status ScreenSelecting the Freedom SW from the Select Device Menu Device Setup Menu ScreenFreedom SW Device Setup Menu Selecting and Changing a Configurable Setting To select and change a configurable settingConfigurable Settings Using Search ModeConfiguring the Freedom SW using the SCP To start equalizing the batteries, do one of the following Equalization ProcedureTo select the Basic Settings menu screen Changing Freedom SW Basic Settings915W Basic Settings Setting Defaults and RangesExamples CalculationsChanging Freedom SW Advanced Settings Advanced Settings is highlighted Freedom SW Owner’s Guide To select the Advanced Settings menu screenSelecting Advanced Settings From the Device Setup Screen Appears only when Equalize support is Enabled Menu Map of the Freedom SW Advanced Settings Inverter Settings Description Inverter Settings MenuUsing the Low Battery Cut Out Lbco Delay SettingsConfiguring the Freedom SW using the SCP Search DelayCharger Settings Menu Charger Settings Menu Description Battery Charger FunctionsSettings menu Custom Battery Settings MenuCustom Battery Settings Menu Description ACIn Settings Menu Description ACIn SettingsAC1 Lo Volt FreqGen Support GenSup ModeGEN Support Menu Description and Valuesa GenSup AmpsStacking Menu Description and Values a Stacking Configuration MenuTo customize the Freedom SW name Setting the Device NameSetting the Device Number If Basic Settings appears instead of Advanced Settings onTo set the Freedom SW device number Using the Advanced Features Resetting the Freedom SW to Default SettingsTo restore Freedom SW default settings Restore Defaults command, press EnterBattery Types Battery Charging ReferenceCharge Algorithm Stages Three-Stage chargingBulk Stage Three-Stage Battery Charging CycleFloat Stage Absorption StageTwo-Stage Charging Cycle Two-Stage Charging ProcessBattery Charging Reference Equalize Charging Equalize ChargingBattery Charging Reference General Troubleshooting Guidelines TroubleshootingInverter Applications Problem LoadsResistive Loads Motor LoadsFault Types Fault type BehaviorFault Types And Behaviors Troubleshooting the Freedom SW via the SCP Fault TypesFaults Types and Behaviors To view a warning list To view a fault listAC Output under Fault MessagesVoltage AC Output overTemperature F44 Battery OverF47 DC Under Voltage ImmediateFault F48 DC Under VoltageF49 DC Over Voltage F58 FET2 Over Temperature F57 FET1 Over TemperatureF63 Power Board Temp UnreadableF64 AC overload Temperature F69 External Sync FailedF68 Transformer Over F70 Unique Dev# NeededF75 Master Inverter Lost F85 PowerBoard OverGenSup Mode setting W48 DC under voltageW69 AGS not connected Physical Specifications SpecificationsInverter Specifications Freedom SW Charger SpecificationsRegulatory Approvals All ModelsPage Schneider Electric Solar Inverters USA Inc97-0019-01-01

815-2024, 815-2012, 815-3012, 815-3024 specifications

Xantrex Technology is a leading manufacturer of advanced power electronics, providing high-quality inverter solutions that cater to diverse applications. Among its impressive portfolio, the Xantrex models 815-3024, 815-3012, 815-2012, and 815-2024 stand out for their reliability and innovative features.

The Xantrex 815-3024 is a robust 3000W inverter designed for 24V systems. Its key feature is the True Sine Wave output, which delivers clean and stable power, making it suitable for sensitive electronics and appliances. It also incorporates an advanced inverter technology that optimizes efficiency and performance. Its compact design allows for easy installation in various setups, such as RVs, boats, and off-grid systems.

Similarly, the Xantrex 815-3012 model caters to 12V applications and offers a continuous output power of 3000W. This inverter excels at providing high surge capability, helping to start up demanding loads such as refrigerators and power tools. The 815-3012 also features an LCD display, which provides real-time data on power consumption, battery voltage, and inverter status, enhancing user experience and enabling proactive management of power usage.

The Xantrex 815-2012 is a 2000W inverter specifically designed for 12V systems. It shares many technological advancements with its higher-powered counterparts, including the True Sine Wave output. This makes it an ideal choice for users seeking a reliable and efficient power source for smaller loads. Additionally, the model includes built-in protection features such as overload, short circuit, and over-temperature safety measures, ensuring longevity and safe operation.

Lastly, the Xantrex 815-2024 offers similar capabilities but is tailored for 24V systems with a power output of 2000W. It is well-suited for applications where moderate power demand exists, such as solar setups and battery-based power solutions. Its compact form factor and lightweight design make it particularly appealing for mobile and temporary installations.

All of these models feature technologies that promote energy efficiency, including automatic low voltage shutdown and smart cooling systems. They boast protective features that ensure the safety and durability of the devices connected to them. With their blend of advanced technologies, reliable performance, and user-friendly interfaces, Xantrex’s 815 Series inverters provide an excellent solution for anyone in need of dependable power conversion.