Desa Tech CDVBNC manual Installation for Horizontal Termination, Installing Vent System in a Chase

Page 12

12

VENTING INSTALLATION

Installation Planning (Cont.) Installation For Horizontal Termination

VENTING INSTALLATION

Continued

Installing Vent System in a Chase

A chase is a vertical boxlike structure built to enclose venting that runs along the outside of a building. A chase is not required for such venting.

NOTICE: Treatment of firestops and construction of the chase may vary from building type to building type. These instructions are not substitutes for the requirements of local building codes. You must fol- low all local building codes.

Note: When installing in a chase, you should insulate the chase as you would the outside walls of your home. This is especially important in cold climates. Minimum clearance between vent pipes and combustible materials such as insulation is 1".

INSTALLATION FOR HORIZONTAL TERMINATION

1.Determine the route your horizontal venting will take. Note: The location of the horizontal vent termination on the exterior wall must meet all local and national building codes and must not be easily blocked or obstructed.

WARNING: Do not recess vent terminal into a wall or siding.

Snorkel terminations are available (see page 18) for 14" and 36" terminations requiring a vertical rise on the exterior of the building (see Figures 18 and 19). Follow the same installation procedures used for standard horizontal terminations. If install- ing the snorkel termination below grade (basement applications), you must provide proper drainage to prevent water from enter- ing the snorkel termination (see Figure 19). Do not back fill around the snorkel termination.

2.Rigid vent pipes and fittings have special twist-lock connec- tions. Assemble the desired combination of pipe and elbows to the appliance adaptor with pipe seams oriented towards the wall or floor.

Twist-lock Procedure: The female ends of the pipes and fit- tings have four locking lugs (indentations). These lugs will slide straight into matching slots on the male ends of adjacent pipes and fittings. (All connections must be sealed with high temperature silicone sealant as specified in the second warn- ing statement on page 11.) Push the pipe sections together and twist one section clockwise approximately one-quarter turn until the sections are fully locked. See Figure 20, page 13. Note: Horizontal runs of vent must be supported every three feet. Use wall straps for this purpose.

Snorkel

12" Minimum

Figure 18 - Snorkel Termination

Snorkel

12" Minimum

Adequate

drainage

Figure 19 - Snorkel Termination with Drainage Pipe

For..com

105501-01G

Image 12
Contents OWNER’S Operation and Installation Manual For Your SafetyFor Your Safety What to do if YOU Smell GAS Table of Contents Safety InformationSafety Information Product Identification Cleaning stove or burner systemProduct Features PRE-INSTALLATION PreparationLocal Codes Glossary of TermsClearances for Standard Installation Cast Iron Stove and DIRECT-VENT Burner System Assembly Stove Body AssemblyInstalling DIRECT-VENT Burner System Into Stove Body Attaching Stove DoorInstalling Optional Blower Accessory Installing GA3750/CDA3620T BlowersInstalling Rear Cover General VentingLocation of Vent Termination General Venting Venting Installation Installation PrecautionsInstallation Planning Installation for Horizontal Termination Installing Vent System in a ChaseVent Pipe Connections Horizontal Termination Configurations Horizontal Termination Configuration for Rigid VentingInstallation for Vertical Termination Flat Ceiling InstallationCathedral Ceiling Installation Vertical Termination ConfigurationsHigh Altitude Installation Parts Lists for Venting Kits and ComponentsStove and DIRECT-VENT Burner System Installation Installing GAS Piping to STOVE/ Burner System LocationInstallation Items Needed Check GAS TypeConnecting STOVE/BURNER System to GAS Supply Pressure Testing Gas Supply Piping SystemChecking GAS Connections Pressure Testing Burner System Gas Connections Turn off burner system see To Turn Off Gas to Appliance,Installing Remote Receiver Installing 9-Volt Battery in Hand-Held Remote Control UnitREMOVING/REPLACING Glass Door Installing LOGS, Lava Rock and Glowing Embers Removing Front Panel from StoveFor Your Safety Read Before Lighting Operating Stove with Burner SystemLighting Instructions Manual Lighting Procedure To Turn OFF GAS To ApplianceOptional Remote Operation Shutting Off Burners Only pilot stays litOperating Optional Blower Accessory Cghrc Series OperationCghrcta Series Operation Pilot Assembly Inspecting BurnersOperating Optional GWMT1 Wall Mounted Thermostat Burner Flame PatternCleaning Maintenance Glass DoorPilot and Burners LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Wiring Diagram Replacement PartsSpecifications Parts Under WarrantyIllustrated Parts Breakdown Models Cdvbnc and CdvbpcParts List KEY Part Number Description QTYStove Chassis Models Cisc and Cisg Models Cisc and Cisg KEY Part Description QTYTechnical Service Service HintsAccessories Owners Registration Form Postage Required 105501-01G Warranty Information