Desa Tech CDVBPC, CDVBNC manual Observed Problem Possible Cause Remedy

Page 29

TROUBLESHOOTING

29

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Burner does not light after pilot is lit

1.

Burner orifice clogged

1.

Clean burner (see Cleaning and

 

 

 

 

Maintenance, page 27) or replace burner

 

 

 

 

orifice

 

2.

Inlet gas pressure is too low

2.

Contact local propane/LP or natural gas

 

 

 

 

company

 

3.

Thermopile leads disconnected or im-

3.

Reconnect leads (see Wiring Diagram,

 

 

properly connected

 

page 31)

 

4.

Thermopile is defective

4.

Replace thermopile

 

 

 

 

 

 

Delayed ignition burner

1.

Manifold pressure is too low

1.

Contact local propane/LP or natural gas

 

 

 

 

company

 

2.

Burner porting or orifice clogged

2.

Clean burner (see Cleaning and Main-

 

 

 

 

tenance, page 27) or replace burner orifice

 

 

 

 

 

Burner backfiring during combustion

1.

Burner orifice is clogged or damaged

1.

Clean burner (see Cleaning and

 

 

 

 

Maintenance, page 27) or replace burner

 

 

 

 

orifice

 

2.

Damaged burner

2.

Replace damaged burner

 

3.

Gas regulator defective

3.

Replace gas control

Slight smoke or odor during initial operation 1. Residues from manufacturing processes and logs curing

1.Problem will stop after a few hours of operation

Burner system produces a whistling noise

1.

Turning gas control knob to HI position

1.

Turn gas control knob to LO position and

when burner is lit

 

when burner is cold

 

let warm up for a minute

 

2.

Air in gas line

2.

Operate burner until air is removed from

 

 

 

 

line. Have gas line checked by local pro-

 

 

 

 

pane/LP or natural gas company

 

3.

Dirty or partially clogged burner orifice

3.

Clean burner (see Cleaning and

 

 

 

 

Maintenance, page 27) or replace burner

 

 

 

 

orifice

 

 

 

 

 

Glass soots

1.

Flame impingement on logs

1.

Adjust the log set so that the flame does

 

 

 

 

not excessively impinge on it

 

2.

Debris around burner air mixer

2.

Inspect the opening at the base of the

 

 

 

 

burner to see that it is NOT packed with

 

 

 

 

any type of material

 

 

 

 

 

Burner system produces a clicking/ticking noise just after burners are lit or shut off

1.Metal expanding while heating or con- tracting while cooling

1.This is common. If noise is excessive, contact qualified service person

Remote does not function

1. Battery is not installed or battery power

 

is low

1.Replace 9-volt batteries in receiver and remote control

For morevisit www..com

105501-01G

Image 29
Contents For Your Safety What to do if YOU Smell GAS OWNER’S Operation and Installation ManualFor Your Safety Safety Information Table of ContentsCleaning stove or burner system Safety Information Product IdentificationPRE-INSTALLATION Preparation Product FeaturesLocal Codes Glossary of TermsClearances for Standard Installation Stove Body Assembly Cast Iron Stove and DIRECT-VENT Burner System AssemblyAttaching Stove Door Installing DIRECT-VENT Burner System Into Stove BodyInstalling GA3750/CDA3620T Blowers Installing Optional Blower AccessoryLocation of Vent Termination Installing Rear CoverGeneral Venting General Venting Installation Planning Venting InstallationInstallation Precautions Installing Vent System in a Chase Installation for Horizontal TerminationVent Pipe Connections Horizontal Termination Configuration for Rigid Venting Horizontal Termination ConfigurationsFlat Ceiling Installation Installation for Vertical TerminationVertical Termination Configurations Cathedral Ceiling InstallationParts Lists for Venting Kits and Components High Altitude InstallationInstalling GAS Piping to STOVE/ Burner System Location Stove and DIRECT-VENT Burner System InstallationInstallation Items Needed Check GAS TypeChecking GAS Connections Connecting STOVE/BURNER System to GAS SupplyPressure Testing Gas Supply Piping System Turn off burner system see To Turn Off Gas to Appliance, Pressure Testing Burner System Gas ConnectionsREMOVING/REPLACING Glass Door Installing Remote ReceiverInstalling 9-Volt Battery in Hand-Held Remote Control Unit Removing Front Panel from Stove Installing LOGS, Lava Rock and Glowing EmbersLighting Instructions For Your Safety Read Before LightingOperating Stove with Burner System To Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Remote Operation Shutting Off Burners Only pilot stays litCghrcta Series Operation Operating Optional Blower AccessoryCghrc Series Operation Inspecting Burners Pilot AssemblyOperating Optional GWMT1 Wall Mounted Thermostat Burner Flame PatternGlass Door Cleaning MaintenancePilot and Burners LogsObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Replacement Parts Wiring DiagramSpecifications Parts Under WarrantyModels Cdvbnc and Cdvbpc Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListStove Chassis Models Cisc and Cisg KEY Part Description QTY Models Cisc and CisgAccessories Technical ServiceService Hints Owners Registration Form Postage Required 105501-01G Warranty Information