TROUBLESHOOTING
29
TROUBLESHOOTING
Continued
| OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY | |||
| Burner does not light after pilot is lit | 1. | Burner orifice clogged | 1. | Clean burner (see Cleaning and | |
| 
 | 
 | 
 | 
 | Maintenance, page 27) or replace burner | |
| 
 | 
 | 
 | 
 | orifice | |
| 
 | 2. | Inlet gas pressure is too low | 2. | Contact local propane/LP or natural gas | |
| 
 | 
 | 
 | 
 | company | |
| 
 | 3. | Thermopile leads disconnected or im- | 3. | Reconnect leads (see Wiring Diagram, | |
| 
 | 
 | properly connected | 
 | page 31) | |
| 
 | 4. | Thermopile is defective | 4. | Replace thermopile | |
| 
 | 
 | 
 | 
 | 
 | 
 | 
| Delayed ignition burner | 1. | Manifold pressure is too low | 1. | Contact local propane/LP or natural gas | |
| 
 | 
 | 
 | 
 | company | |
| 
 | 2. | Burner porting or orifice clogged | 2. | Clean burner (see Cleaning and Main- | |
| 
 | 
 | 
 | 
 | tenance, page 27) or replace burner orifice | |
| 
 | 
 | 
 | 
 | 
 | |
| Burner backfiring during combustion | 1. | Burner orifice is clogged or damaged | 1. | Clean burner (see Cleaning and | |
| 
 | 
 | 
 | 
 | Maintenance, page 27) or replace burner | |
| 
 | 
 | 
 | 
 | orifice | |
| 
 | 2. | Damaged burner | 2. | Replace damaged burner | |
| 
 | 3. | Gas regulator defective | 3. | Replace gas control | |
Slight smoke or odor during initial operation 1. Residues from manufacturing processes and logs curing
1.Problem will stop after a few hours of operation
| Burner system produces a whistling noise | 1. | Turning gas control knob to HI position | 1. | Turn gas control knob to LO position and | 
| when burner is lit | 
 | when burner is cold | 
 | let warm up for a minute | 
| 
 | 2. | Air in gas line | 2. | Operate burner until air is removed from | 
| 
 | 
 | 
 | 
 | line. Have gas line checked by local pro- | 
| 
 | 
 | 
 | 
 | pane/LP or natural gas company | 
| 
 | 3. | Dirty or partially clogged burner orifice | 3. | Clean burner (see Cleaning and | 
| 
 | 
 | 
 | 
 | Maintenance, page 27) or replace burner | 
| 
 | 
 | 
 | 
 | orifice | 
| 
 | 
 | 
 | 
 | 
 | 
| Glass soots | 1. | Flame impingement on logs | 1. | Adjust the log set so that the flame does | 
| 
 | 
 | 
 | 
 | not excessively impinge on it | 
| 
 | 2. | Debris around burner air mixer | 2. | Inspect the opening at the base of the | 
| 
 | 
 | 
 | 
 | burner to see that it is NOT packed with | 
| 
 | 
 | 
 | 
 | any type of material | 
| 
 | 
 | 
 | 
 | 
 | 
Burner system produces a clicking/ticking noise just after burners are lit or shut off
1.Metal expanding while heating or con- tracting while cooling
1.This is common. If noise is excessive, contact qualified service person
| Remote does not function | 1. Battery is not installed or battery power | 
| 
 | is low | 
1.Replace 