Desa Tech CDVBNC, CDVBPC manual Cathedral Ceiling Installation, Vertical Termination Configurations

Page 16

16

VENTING INSTALLATION

Installation For Vertical Termination (Cont.)

VENTING INSTALLATION

Continued

Cathedral Ceiling Installation

1.Remove shingles or other roof covering as necessary to cut the rectangular hole for the support box. Mark the outline of the cathedral ceiling support box on the roof sheathing using the locating hole as a center point.

2.Cut the hole 1/8" larger than the support box outline (see Fig- ure 31).

3.Lower the support box through the hole in the roof until the bottom of the box extends at least 2" below the ceiling (see Figure 31). Align the support box vertically and horizontally using a level. Temporarily tack the support box in place through the inside walls and into the roof sheathing.

4.Using tin snips, cut the support box from the top corners down to the roofline and fold the resulting flaps over the roof sheath- ing (see Figure 32). Apply a bead of non-hardening mastic around the top edges of the support box to make a seal be- tween the box and the roof. Nail in place with roofing nails. Remove any combustible material that might be inside of the support box.

5.Complete the cathedral ceiling installation by following the same procedures outlined in steps 2 through 7 for Flat Ceiling Installation, page 15.

Level

Cathedral ceiling support box

2" minimum below finished ceiling

Cut hole 1/8" larger than support box when projected onto roofline

Figure 31 - Cathedral Ceiling Support Box Installation

Nonhardening Mastic under all edges of support box before nailing

Figure 32 - Installed Cathedral Ceiling Support Box

Vertical Termination Configurations

Figures 33 and 34 and Figures 35 and 36 on page 17 show four different configurations for vertical termination. All connections must be sealed with high temperature silicone sealant as specified in the second warning statement on page 11.

Venting with One 90° Elbow

Vertical (V)

Horizontal (H)

5' min.

2' max.

6' min.

4' max.

7' min.

6' max.

8' min.

8' max.

20' max.

8' max.

Note: Install restrictor into 4" collar of burner system as shown.

Figure 33 - Vertical Rigid Venting Configuration Using One 90° Elbow

Venting with Two 90° Elbows

Vertical (V) Horizontal (H1) +

Horizontal (H2)

5' min.

2' max.

6' min.

4' max.

7' min.

6' max.

8' min.

8' max.

20' max.

8' max.

Note: Install restrictor into 4" collar of burner system as shown.

Figure 34 - Vertical Rigid Venting Configuration Using Two 90° Elbows with Two Horizontal Runs

For..com

105501-01G

Image 16
Contents For Your Safety OWNER’S Operation and Installation ManualFor Your Safety What to do if YOU Smell GAS Table of Contents Safety InformationSafety Information Product Identification Cleaning stove or burner systemProduct Features PRE-INSTALLATION PreparationLocal Codes Glossary of TermsClearances for Standard Installation Cast Iron Stove and DIRECT-VENT Burner System Assembly Stove Body AssemblyInstalling DIRECT-VENT Burner System Into Stove Body Attaching Stove DoorInstalling Optional Blower Accessory Installing GA3750/CDA3620T BlowersGeneral Venting Installing Rear CoverLocation of Vent Termination General Venting Installation Precautions Venting InstallationInstallation Planning Installation for Horizontal Termination Installing Vent System in a ChaseVent Pipe Connections Horizontal Termination Configurations Horizontal Termination Configuration for Rigid VentingInstallation for Vertical Termination Flat Ceiling InstallationCathedral Ceiling Installation Vertical Termination ConfigurationsHigh Altitude Installation Parts Lists for Venting Kits and ComponentsStove and DIRECT-VENT Burner System Installation Installing GAS Piping to STOVE/ Burner System LocationInstallation Items Needed Check GAS TypePressure Testing Gas Supply Piping System Connecting STOVE/BURNER System to GAS SupplyChecking GAS Connections Pressure Testing Burner System Gas Connections Turn off burner system see To Turn Off Gas to Appliance,Installing 9-Volt Battery in Hand-Held Remote Control Unit Installing Remote ReceiverREMOVING/REPLACING Glass Door Installing LOGS, Lava Rock and Glowing Embers Removing Front Panel from StoveOperating Stove with Burner System For Your Safety Read Before LightingLighting Instructions Manual Lighting Procedure To Turn OFF GAS To ApplianceOptional Remote Operation Shutting Off Burners Only pilot stays litCghrc Series Operation Operating Optional Blower AccessoryCghrcta Series Operation Pilot Assembly Inspecting BurnersOperating Optional GWMT1 Wall Mounted Thermostat Burner Flame PatternCleaning Maintenance Glass DoorPilot and Burners LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Wiring Diagram Replacement PartsSpecifications Parts Under WarrantyIllustrated Parts Breakdown Models Cdvbnc and CdvbpcParts List KEY Part Number Description QTYStove Chassis Models Cisc and Cisg Models Cisc and Cisg KEY Part Description QTYService Hints Technical ServiceAccessories Owners Registration Form Postage Required 105501-01G Warranty Information