Desa Tech CDVBPC, CDVBNC Operating Stove with Burner System, For Your Safety Read Before Lighting

Page 23

STOVE AND DIRECT-VENT BURNER SYSTEM INSTALLATION

Installing Logs, Lava Rock, and Glowing Embers (Cont.)

OPERATING STOVE WITH BURNER SYSTEM

For Your Safety Read Before Lighting

LIghting Instructions

23

STOVE AND DIRECT-VENT BURNER SYSTEM INSTALLATION

Continued

7.Pull ember material apart into pieces no larger than a dime. Place these pieces loosely and sparingly directly onto the ex- posed section of the front burner and along the space between the burner and grate prongs (see Figure 54). This will create the glowing ember appearance as the flame touches the ember material. Do not block air slots by using too much ember ma- terial in one area. It is not necessary to use all of the ember material provided.

8.Replace the glass door and stove front. See Removing/Replac- ing Glass Door, pages 21 and 22.

WARNING: The glass door must be securely in place before running this burner system. Do not run this burner system if glass is missing or broken.

Figure 54 - Placing Ember Material on Burner

OPERATING STOVE WITH BURNER SYSTEM

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information above.

2.Open lower panel.

3.Turn ON/OFF switch to “OFF”.

4.Turn off all electric power to the burner system.

5.Push in gas control knob slightly and turn clockwise to “OFF”.

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information above. If you don't smell gas, go to the next step.

7.The pilot is located by the main burner and should not require accessing for lighting.

8.Turn gas control knob counterclockwise to “PILOT”.

For morevisit www..com

105501-01G

Image 23
Contents For Your Safety What to do if YOU Smell GAS OWNER’S Operation and Installation ManualFor Your Safety Safety Information Table of ContentsCleaning stove or burner system Safety Information Product IdentificationGlossary of Terms Product FeaturesPRE-INSTALLATION Preparation Local CodesClearances for Standard Installation Stove Body Assembly Cast Iron Stove and DIRECT-VENT Burner System AssemblyAttaching Stove Door Installing DIRECT-VENT Burner System Into Stove BodyInstalling GA3750/CDA3620T Blowers Installing Optional Blower AccessoryLocation of Vent Termination Installing Rear CoverGeneral Venting General Venting Installation Planning Venting InstallationInstallation Precautions Installing Vent System in a Chase Installation for Horizontal TerminationVent Pipe Connections Horizontal Termination Configuration for Rigid Venting Horizontal Termination ConfigurationsFlat Ceiling Installation Installation for Vertical TerminationVertical Termination Configurations Cathedral Ceiling InstallationParts Lists for Venting Kits and Components High Altitude InstallationCheck GAS Type Stove and DIRECT-VENT Burner System InstallationInstalling GAS Piping to STOVE/ Burner System Location Installation Items NeededChecking GAS Connections Connecting STOVE/BURNER System to GAS SupplyPressure Testing Gas Supply Piping System Turn off burner system see To Turn Off Gas to Appliance, Pressure Testing Burner System Gas ConnectionsREMOVING/REPLACING Glass Door Installing Remote ReceiverInstalling 9-Volt Battery in Hand-Held Remote Control Unit Removing Front Panel from Stove Installing LOGS, Lava Rock and Glowing EmbersLighting Instructions For Your Safety Read Before LightingOperating Stove with Burner System Shutting Off Burners Only pilot stays lit Manual Lighting ProcedureTo Turn OFF GAS To Appliance Optional Remote OperationCghrcta Series Operation Operating Optional Blower AccessoryCghrc Series Operation Burner Flame Pattern Pilot AssemblyInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatLogs Cleaning MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Parts Under Warranty Wiring DiagramReplacement Parts SpecificationsModels Cdvbnc and Cdvbpc Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListStove Chassis Models Cisc and Cisg KEY Part Description QTY Models Cisc and CisgAccessories Technical ServiceService Hints Owners Registration Form Postage Required 105501-01G Warranty Information