Installation Manual
Models ECCB/TCCB 30” – 36” ENGLISH
Electrical Connections
DANGER
Disconnect power before servicing the product. Failure to do so could result in death or electrical shock.
General information
This cooktop does not require a neutral connection. If the cooktop is to be completely enclosed in a cabinet, feed the cooktop cable through the opening in the cabinet. Make the electrical connection following the appropriate steps for your installation.
Your cooktop must be connected to the proper electrical voltage and frequency as specified in the table on the right.
Figure 13. Location of serial tag
Connect with copper wire only
If the house has aluminum wiring, follow the procedure below:
1.Connect the aluminum wiring to the copper wire by using special connectors designed and Underwriters
2.Aluminum/copper connection must conform with local codes and industry- accepted wiring practices.
The flexible conduit (supplied) 3 feet long (100 cm) located at the right rear of the cooktop bottom box should be connected directly to junction box. Do not cut the conduit. A U.L - or CSA - listed conduit connector must be provided at each end of the power
supply cable (at the cooktop and at the junction box.) A time delay fuse or circuit breaker is recommended. Do not ground to a gas pipe. Do not have a fuse in the grounding or neutral circuit.
Fuse both supply (phase) lines.
WARNING
Improper connection of aluminum house wiring to the copper leads can result in a serious problem.
|
|
| Required | Minimum |
| Model | Power | power | supply wire |
|
|
| supply | size |
| TCCB 33052/** |
|
|
|
| TCCB 33053/** |
|
|
|
| TCCB 33066/** |
|
|
|
30” | TCCB 33067/** | 6.7 kW | 240 V 28 A | No. |
ECCB 33050/** | 60 Hz | 10AWG | ||
| ECCB 33051/** |
|
|
|
| ECCB 33070/** |
|
|
|
| ECCB 33071/** |
|
|
|
| TCCB 33656/** |
|
|
|
| TCCB 33657/** | 7.6 kW | 240 V 32 A | No. |
| TCCB 33668/** | 60 Hz | 10AWG | |
36” | TCCB 33669/** |
|
|
|
ECCB 33654/** |
|
|
| |
|
|
|
| |
| ECCB 33655/** | 9.4 kW | 240 V 39 A | No. |
| ECCB 33674/** | 60 Hz | 10AWG | |
| ECCB 33675/** |
|
|
|
*Digits identifying color cooktop
National Fire Protection Association
Batter/march Park Quincy, Massachusetts 02269
A
12