| Installation Manual | |
|
|
| Models ECCB/TCCB 30” – 36” | ENGLISH | |
Recommended Minimum |
|
|
|
| |
kW Rating on | Circuit protection | Wire size |
|
|
|
serial plate | in amperes | (AWG) |
|
|
|
20 | 12 |
|
|
| |
30 | 10 |
|
|
| |
40 | 8 |
|
|
| |
50 | 8 |
|
|
| |
60 | 6 |
|
|
| |
Be sure your appliance is properly installed and |
|
|
| ||
grounded by a qualified technician. Ask your |
|
|
| ||
dealer to recommend a qualified technician or an |
|
|
| ||
authorized repair service. This cooktop does not |
|
|
| ||
require a neutral connection. If the cooktop Is to |
|
|
| ||
be completely enclosed In a cabinet, feed the |
|
|
| ||
cooktop cable through the opening in the cabinet. |
|
|
| ||
Make the electrical connection following the |
|
|
| ||
appropriate steps for your installation. |
|
|
|
| |
This appliance is manufactured with a green ground |
|
|
| ||
wire connected to the cooktop chassis. After making | Figure 14. |
| |||
sure that the power has been turned off, connect the |
| ||||
|
|
| |||
flexible conduit from the cooktop to the junction box |
|
| |||
using a U.L. listed conduit connector. Figures 14 and |
| ||||
15 and the instructions provided below present the | Refer to figure 15: |
| |||
most common way of connecting the cooktops. Your | 1. Connect the green ground wire from the cooktop | ||||
local codes and ordinances, of course, take |
|
| to the ground wire in the junction box (bare or | ||
precedence over these instructions. Complete |
| green colored wire). |
| ||
electrical connections according to local codes and | 2. Connect the red and black leads from the cooktop | ||||
ordinances |
|
| |||
|
|
| to the corresponding leads in the junction box. | ||
|
|
|
| ||
| DANGER |
| 3. Connect the white wire from the cooktop to the | ||
|
|
| neutral (gray or white) wire in the junction box. | ||
Risk of Electric Shock, frame grounded to | 4. | Terminate and insulate the neutral (gray or white | |||
| colored wire) in the junction box. |
| |||
neutral of appliance through a link. |
|
|
| ||
|
|
|
|
Grounding through the neutral conductor is prohibited for new
Where local codes allow the connection of ground wire from the cooktop to the branch circuit neutral wire (gray or white colored wire) proceed as follows (see figure 14).
1. If local codes permit, connect the green GROUND wire from the cooktop to the branch circuit neutral wire (gray or white colored wire).
2. Connect the red and black leads from the cooktop to the corresponding leads in the junction box.
Figure 15.
13