Removing the left (freezer) door with water line connection Relnstalling the right (refrigerator) door
•Puii up the water feed tube while pressing area (Figure 1) as shown in the figure below.
/(2)
°NOTE: If a tube end is deformed or abraded, trim the part away. Disconnecting the tube under the door causes about 0.13 gallons (0.5 liters) water to flow out. Put a large
container at end of tube to prevent water from draining onto the floor.
ure 1
(2)
(i)\
1. Place the door onto the lower hinge pin.
2.Fit top hinge (4) over hinge lever latch (5) into place. Rotate
lever (3) counterclockwise to secure hinge.
NOTE : Regardless of hinge lever type, installation process is the same.
3.Hook tab an switch side of corner under edge of wire
opening in cabinet tap. Position cover (2) into place. Insert and tighten cover screw (1).
Relnstafflng the Jeff(freezer) door
(3)
/
(6)
(7)
Type 1
1. Open the door. Remove the top hinge cover screw (1). 2.Use a fiat blade screwdriver to pry back the hooks (not
shown) on the cabinet underside of the cover (2). Lift up the cover.
3.Disconnect all the wire harnesses (3). 4.Remove the grounding screw (4).
5.Rotate hinge lever (5) counterclockwise. Lift the top hinge
(6) free of the hinge lever latch (7).
NOTE: Regardless of hinge lever type, removal process is the
same.
CAUTION: When lifting the hinge free of the latch, be careful that the door does not fall forward.
6.Lift the door from the lower hinge pin being careful to pull the water lines through the lower hinge pin.
7.Place the door, inside facing up, on a non scratching surface.
(2)
(I)\
/
(6) | / |
|
(7)
Type 1
1.Feed the water tubes through the lower hinge pin and place the door onto the lower hinge pin.
2.Fit top hinge (6) over hinge lever latch (7) and into place.
Rotate lever (5) clockwise to secure hinge.
NOTE: Regardless of hinge lever type, installation process is the same.
3.Install the grounding screw (4) and connect all the wire harnesses (3).
4.Hook tab on door switch side of cover (2) under edge of wire opening in cabinet top. Position cover into place. Insert and tighten cover screw (1).
5.Reconnect the water tubes by inserting the tubes into the connectors.
Coilet
Tube
Insert Line
11