Filter Performance Data Sheet
Model Number ADQ72910902
Use with replacement cartridge ADQ72910902
This system has been tested according to NSF/ANSI 42 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration Jess than equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42.
System | tested | and | certified |
| by NSF International | against NSF/ANSI Standard 42 for the reduction of Chlorine, Taste and | ||||||||
Odor and | Nominal | Particulate | Class III. |
|
|
|
|
|
|
| ||||
Contaminant | Reduction |
| Average | Influent | Challenge | Avg. Product Water | Average % | Min. Required | Max. | Effluent mcj/L | ||||
|
|
|
|
| Influent | concentration. |
| Concentration | Reduction | Reduction |
|
| ||
Particulate |
| Class | III Particles | 48000 | At least | 10000 |
| 7.5 | 99.9 | 26 |
| |||
|
|
|
|
|
|
|
|
| ||||||
5m to 15urn |
|
|
|
|
| particles/ml |
|
|
|
|
|
|
| |
Chlorine | taste and | odor |
| 2.0 mg/L | 2.0 mg/L | 4- 10% | mg/L | 97.4 | _>50% | 0.06 | mg/L |
°To a capacity of 500 gallons (1892 L).
°Note that while the testing was performed under standard laboratory conditions, actual performance may vary.
Application Guidelines / Water Supply Parameters
Water pressure | 20 - 125 psi (138 - 862 kPa) |
Water temperature 34°F - IO0°F (1°C - 3Z8°C)
Service flow | 0.5 gpm (1.9 Ipm) |
To reduce the risk associated with ingestion
of contaminants due to use with water that is
microbioiogicaJiy unsafe or of unknown quality.
Do not use with water that is microbioJogically unsafe or of unknown quality without adequate disinfection before or after the system.
Systems must be installed and operated in accordance with manufacturer's recommended procedures and guidelines.
To reduce the risk of property damage due to water leakage:
°Read and follow Use instructions before installation and use of this system.
°Install on COLD water lines only.
°Company with all state and local plumbing codes. Never install or operate where inlet water pressure may exceed 125 psi (862 kPa).
°Protect filter from freezing. Remove filter in temperatures below 34°F (1°C).
°Replace cartridge at specified service interval. Cartridge MUST be replaced at least every 6 months.
°After replacing the water filter cartridge, dispense 2.5 gallons (9.46 liters) of water to purge the system,
depressing and releasing the dispenser pad in cycles of 30 seconds ON and 60 seconds OFF. Discard the
purged water.
To purchase a replacement fiiteb visit your local Sears store
or call
www.sears.com
Product distributed in the United States by Sears Brands Management Corporation, Hoffman Estates, IL 60179.