Kenmore 795.7205 manual Based on the use of Cryptosporidium parvum oocysts

Page 30

Performance Data Sheet

The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as specified in NSF/ANSI Standard 42 and Standard 53.

System tested and certified by NSF International against NSF/ANSI Standard 42 and Standard 53 for the reduction of substances listed below.

 

 

 

 

 

 

 

 

 

 

 

 

Average

Max Permissible

NSF Reduction

NSF Test

Contaminant

Reduction

Average

NSF

specified

Challenge

Avg %

Product

Water

Product

Water

 

 

 

 

 

 

 

Infiuent

 

Concentration

Reduction

Concentration

Concentration

Requirements

Report

Chlorine

Taste and

Odor

2.1 mg/L

 

2.0

mg/L

_+10%

9Z2%

0.06

mg/L

N/A

_>50%

J-00049247

Nominal

Particulate

Class I,,

5,600,000

At

least 10,000

particles/mL

98.7%

73,000

pts/ml

N/A

_>85%

J-00049282

_>0.5 to

< 1.0 JJm

 

pts/mL

 

 

 

 

 

 

 

 

 

 

 

 

Asbestos

 

 

 

190 MFL

107 to 108 MFL; fibers greater

>99%

< 1 MFL

N/A

_>99%

J-0004928

 

 

 

 

than 10 JJm in length

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Atrazine

 

 

 

0.0094

mg/L

 

0.009

mg/L

_+ 10%

94.7%

0.00005

mg/L

0.003

mg/L

N/A

J-00049293

Benzene

 

 

 

0.016

mg/L

 

0.015

mg/L

_+ 10%

96.7%

0.005

mg/L

0.005

mg/L

N/A

J-00049300

Carbofuran

 

 

0.08

mg/L

 

0.08

mg/L

_+ 10%

98.1%

0.002

mg/L

0.04

mg/L

N/A

J-00049294

Lindane

 

 

 

0.002

mg/L

 

0.002

mg/L

_+ 10%

98.2%

0.00004

mg/L

0.0002

mg/L

N/A

J-00051975

P-Dichlorobenzene

 

0.22

mg/L

 

0.225

mg/L

_+10%

99.8%

0.0005

mg/L

0.075

mg/L

N/A

J-00049298

Toxaphene

 

 

0.014

mg/L

 

0.015

mg/L

_+ 10%

93%

0.001

mg/L

0.003

mg/L

N/A

J-00049302

2,4-D

 

 

 

 

0.213

mg/L

 

0.210

mg/L

_+ 10%

95.2%

0.009

mg/L

0.07

mg/L

N/A

J-00049284

Lead

pH @6.5

 

0.150

mg/L

 

0.15 mg/L

_+ 10%

>99.3%

0.001

mg/L

0.010

mg/L

N/A

J-00051974

Lead

pH

@8.5

 

0.150

mg/L

 

0.15 mg/L

_+ 10%

>99.3%

0.001

mg/L

0.010

mg/L

N/A

J-00049277

Mercury

@

pH 6.5

 

0.0059

mg/L

 

0.006

mg/L

_+ 10%

96.1

0.0002

mg/L

0.002

mg/L

N/A

J-00053886

Mercury

@

pH 8.5

 

0.0058

mg/L

 

0.006

mg/L

_+ 10%

90.1

0.0006

mg/L

0.002

mg/L

N/A

J-00051972

Cyst _

 

 

 

 

120,000

cysts/L

Minimum

50,000 cysts/L

99.99%

<1 cyst/L

N/A

_>99.95%

J-00049281

Based on the use of Cryptosporidium parvum oocysts

3O

Image 30
Contents Use & Care Guide Manual de Uso y Cuidado Guide dUtiisafion ef dEnfretienService WarrantyConnecting ElectricalKenmore Elite Limited Warranty Discialmer of impiled warranties llmlfatian of remediesMaster Protection Agreements MY-HOMEBasic Safety Precautions Before YOU Throw Away Your OLD Refrigerator Or FreezerUSE of Extension Cords To Connect ElectricityRecommended Grounding Method Electrical Shock HazardPage Excessive Weight Hazard Excessive Weight HazardPrior to USE Shock HazardTo Remove DoorRemoving Refrigerator Handle Removing Freezer Drawer Handle HOW to Remove Freezer Door HandleHOW to Replace Freezer Door Handle Replacing Freezer Drawer HandleRemoving and Replacing To remove the left refrigerator doorTo remove the right refrigerator door f Left Door Right DoorPutt out each rait to futt extension Leveling and Door Alignment LevelingDoor Alignment Refrigerator Temp Control ranges from 33F to Setting the ControlsAirflow Freezer Temp Control range is from -6F to 8FAir Filter Air Filter ResetWater Filter Reset Ultra Ice Accent Light/Light Sensor CDaar Alarm C Cantral LackTo deactivate Page Automatic Icemaker Personal Injury HazardNormal Sounds YOU MAY Hear When YOU should SET the Icemaker Power Switch to OFF OAutomatic Icemaker Preparing for VacationFood Storage Guide Water Dispenser PushAdjusting Shelves Cantilever Foldlng Shelf on some modelsTemperature Controlled Pantry Drawer CrisperFreezer Section Install a New Air FilterReplacing the AiR Filter Extra iCE BiNDurabase Pullout DrawersTop Drawer Durabase DividerWater Filter Water Filter Bypass PlugBased on the use of Cryptosporidium parvum oocysts Microblologlcally unsafe or of unknown quality Water Treatment Device Certificate Number Exterior General Cleaning TipsExplosion Hazard Door Liners and GasketsWhen YOU GO on Vacation Light Bulb ReplacementPower Interruptions When YOU MoveElectrical Shock Hazard Water PressureWhat YOU will Need Drill the Hole for the Valve INSTALLATiON iNSTRUCTiONSShut OFF the Main Water Supply Connect the Tubing to the ValveFlush OUT the Tubing Connect the Tubing to the RefrigeratorStart the Icemaker Cooling 40-120Operating Section Ice storage COOLING/ICE & WaterStore ShutoffICE & Water Doors are not closed completelyICE & Water ICE & Water Sure that Sides OperationSystem SoundParts & Features Or stickyLED Using the Kenrnore Connect TM System Your Home