Telit Wireless Solutions 1vv0300773a manual Overview

Page 6

GE863-PRO3Hardware User Guide

1vv0300773a Rev. 0 - 24/01/08

1 Overview

The scope of this document is the description of some hardware solutions useful for developing a product with the Telit GE863-PRO3module.

In this document all the basic functions of a M2M device will be taken into account; for each one of them a proper hardware solution will be suggested and eventually the wrong solutions and common errors to be avoided will be evidenced. Obviously this document cannot embrace the whole hardware solutions and products that may be designed. The wrong solutions to be avoided shall be considered as mandatory, while the suggested hardware configurations shall not be considered mandatory, instead the information given shall be used as a guide and a starting point for properly developing your product with the Telit GE863-PRO3module. For

further hardware details that may not be explained in this document refer to the Telit GE863-PRO3Product Description document.

NOTICE

(EN) The integration of the GSM/GPRS GE863-PRO3cellular module within user application shall be done according to the design rules described in this manual.

(IT) L’integrazione del modulo cellulare GSM/GPRS GE863-PRO3all’interno dell’applicazione dell’utente dovrà rispettare le indicazioni progettuali descritte in questo manuale.

(DE) Die integration des GE863-PRO3GSM/GPRS Mobilfunk-Moduls in ein Gerät muß gemäß der in diesem Dokument beschriebenen Kunstruktionsregeln erfolgen

(SL) Integracija GSM/GPRS GE863-PRO3modula v uporabniški aplikaciji bo morala upoštevati projektna navodila, opisana v tem piročniku.

(SP) La utilización del modulo GSM/GPRS GE863-PRO3debe ser conforme a los usos para los cuales ha sido deseñado descritos en este manual del usuario.

(FR) L’intégration du module cellulaire GSM/GPRS GE863-PRO3dans l’application de l’utilisateur sera faite selon les règles de conception décrites dans ce manuel.

GE863-PRO3

The information presented in this document is believed to be accurate and reliable. However, no responsibility is assumed by Telit Communications S.p.A. for its use, nor any infringement of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent rights of Telit Communications S.p.A. other than for circuitry embodied in Telit products. This document is subject to change without notice.

Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved

page 6 of 64

Image 6
Contents GE863-PRO3Hardware User Guide Contents GE863-PRO 3 Hardware User Guide This document is relating to the following products Disclaimer Overview GE863-PRO3Mechanical Dimensions Telit GE863-PRO3module overall dimension areLength 41,4 mm Width 31,4 mm Thickness 3,6 mm GE863-PRO3module connections C11 Simrst C12 Simio D1 Charge D2 VAUX1 DTE GPIO7 / Rftxdisable GSMC2 Vbatt C3 Vrtc D10 GND D11 Simvcc D12 Simclk E1 GND E2 PwrmonPB9 Nrst Reset ARMPB8 ON/OFF*-APPB1 PB0PB2 PB7XOUT32 HdmbXIN32 PA3VBATT2 Reserved GNDBalls Layout ARM Port IO multiplexing ARM PIO Controller a multiplexingARM PIO Controller B multiplexing ARM PIO Controller C multiplexing Hardware Commands Turning on the GE863-PRO3GSM/GPRS Engine10k +1,8/5Hardware Unconditional Reboot of GSM/GPRS Engine 2Turning OFF the GE863-PRO3GSM/GPRS EngineHardware shutdown Turning ON/OFF the GE863-PRO3ARM ON/OFF*-AP # GND AT+CFUN=1 Power SupplyGSM Power Supply Requirements AT+CFUN=4ARM Power Supply Requirements Vrtc Backup supplySuggested circuit is General Design RulesElectrical design Guidelines 817A19A Seiko1.1 + 5V input Source Power Supply Design Guidelines 1.2 + 12V input Source Power Supply Design Guidelines Battery Source Power Supply Design Guidelines Battery Charge control Circuitry Design Guidelines GE863-PRO3Hardware User Guide Thermal Design Guidelines Power Supply PCB layout Guidelines Antenna GSM Antenna RequirementsGSM Antenna PCB line Guidelines 50 ohmGSM Antenna installation Guidelines Electro Magnetic Interference GuidelinesLogic level specifications Absolute Maximum Ratings -Not Functional Parameter Min MaxOperating Range Interface levels Cmos Level Min Max Cmos 1.8V-A Current characteristics Level Typical GSM Gpio Current characteristics Level TypicalCmos 3.1V Current characteristics Level Typical Operating Range Interface levels Cmos Vrtc Level Min MaxSignal Function Phone resetSignal Min Max Serial Ports Modem Serial Port Modem Serial Port 2 DebugSignals of the GE863-PRO3GSM/GPRS engine serial port are RS232 level translation An example of level translation circuitry of this kind is GE863-PRO3Hardware User Guide Audio Section Overview Input Lines Microphone Short descriptionInput Lines Characteristics Micmt 1st differential microphone pathOutput Lines Speaker Output Lines Characteristics Earmt Differential Line-out Drivers PathEvaluation Kit for Telit GE863- PRO3 Modules 10 GSM/GPRS General Purpose I/O ON/OFFUsing the RF Transmission Control GPIO7 Using a Gpio Pad as InputUsing a Gpio Pad as Output 10.4Using the Rftxmon Output GPIO3Using the Alarm Output Using the Buzzer Output GPIO410.7Indication of network service availability LED statusDevice Status 10.9VAUX1 power output Operating Range VAUX1 power supplyRTC Bypass out Stencil Mounting the GE863-PRO3on the Application Board11.1General PCB pad DesignSolder paste 11.1.4 GE863-PRO3Solder Reflow Following is the recommended solder reflow profile3C/second max Packing System Section A-AModules orientation on tray Moisture Sensibility Conformity Assessment Issues Safety Recommandations Document Change Log Revision Date Changes