Simer Pumps M40P-04, M40-04 owner manual Unplug the Pump, Performance, Troubleshooting Chart

Page 5

Installation

5

5

Unplug

UNPLUG THE PUMP

Unplug the pump before all the water is completely gone.

DO NOT RUN PUMP DRY!

PERFORMANCE

The pump will deliver 350 gallons/1325 liters per hour with an unrestricted dis- charge line. If the discharge line is restrict- ed or raised and the pressure on the pump outlet port increases, it will pump less water.

NOTICE: This pump’s motor has brushes. Inspect the brushes frequently; replace them if they’re worn.

TROUBLESHOOTING CHART

SYMPTOM

PROBABLE CAUSE(S)

CORRECTIVE ACTION

 

 

 

Pump stops without

Pump has overheated

Wait for overload to reset; pump will automatically

warning

and thermal overload

restart

 

has tripped

 

 

Discharge hose too long

Use shorter hose or reduce lift

 

or discharge lift higher

 

 

than 28’

 

Pump Won’t Prime

Pump body not oiled

Add oil through inlet port (see Page 3)

 

Suction hose too long or

Use 1/2" Suction hose, 25’ long or less

 

too small

(the shorter the hose, the better)

 

Worn impeller

Replace impeller

 

Suction leaks

Replace hose washer, check for leaks in hose

 

Suction hose kinked

Straighten out suction hose

 

or coiled

 

 

 

 

Pump leaks

Shaft U-cup seal leaks

Replace shaft seal

 

Cover O-Ring leaks

Replace cover O-Ring

 

 

 

Pump runs, pumps

Worn impeller

Replace impeller

little or no water

Bad motor brushes

Replace motor brushes

 

 

Bad U-cup shaft seal

Replace shaft seal

 

(pump will leak)

 

 

Suction or discharge hose

Straighten out hose

 

kinked or coiled

 

For parts or assistance, call Simer Customer Service at 1-800-468-7867

Image 5
Contents Model M40P-04 Model M40-04Simer Limited Warranty SafetySafety Information OIL the Pump InstallationKeep the Hoses AS Straight AS Possible Performance Troubleshooting ChartUnplug the Pump Repair Parts Repair Parts Brush InstallationGarantie limitée Simer SécuritéConsignes DE Sécurité Huiler LA Pompe OU Plus Gros DE 1,3 CM 1/2 POBON Garder LES Tuyaux Souples Aussi Droits QUE PossibleTableau DE Recherche DES Pannes Débrancher LA PompeRendement Pièces DE Rechange Pièces de rechangeGarantia Limitada de Simer SeguridadInformación Sobre LA Seguridad DE 1/2 O Mayor USE UNA MangueraAceite LA Bomba InstalaciónLA Manguera DE Admisión VA Dentro DEL Agua InstalaciónMantenga LAS Mangueras LO MÁS Rectas Posibles Cuadro DE Localización DE Fallas Desenchufe LA BombaDesempeño Repuestos Repuestos Instalación de escobillasModelos M40-04, M40P-04

M40-04, M40P-04 specifications

Simer Pumps has made a significant mark in the industry with the introduction of its M40P-04 and M40-04 models. These pumps are engineered to meet a wide variety of demanding applications, delivering reliability and performance that users can trust.

The Simer M40P-04 is designed with versatility in mind. It features a strong and durable construction that allows it to perform efficiently under varying conditions. The pump is powered by a robust motor that ensures high flow rates, making it suitable for applications in agriculture, building services, and general water transfer. The M40P-04 includes an integrated thermal overload protection system, which prevents motor overheating and ensures a longer lifespan.

On the other hand, the M40-04 model shares many of the same reliable traits as the M40P-04 but is optimized for slightly different use cases. It boasts a compact design that allows for easy installation in tight spaces while maintaining exceptional performance levels. This model is particularly well-suited for residential applications such as lawn irrigation systems and water features.

Both pumps utilize advanced technologies that enhance their operational efficiency. For instance, Simer has incorporated a high-quality impeller design in both models, which minimizes energy consumption while maximizing water flow. This design not only reduces operating costs but also makes them environmentally friendly.

In terms of characteristics, the M40P-04 comes with a built-in pressure switch, which automatically turns the pump on and off based on water demand, ensuring optimal performance and energy savings. Similarly, the M40-04 features a self-priming mechanism, allowing it to draw water from underground sources without the need for manual priming.

Durability is a key aspect of both models. They are constructed with corrosion-resistant materials, making them suitable for various water types, including those containing debris or sediments. This durability is complemented by easy maintenance features, allowing users to keep the pumps in optimal condition with minimal effort.

Ultimately, the Simer M40P-04 and M40-04 pumps stand out in the market for their reliability, innovative technology, and practical design. They are ideal choices for those seeking efficient, robust, and user-friendly pumping solutions for various applications. With their combination of power and efficiency, both models promise to deliver outstanding performance over time.