Simer Pumps M40-04, M40P-04 owner manual DE 1,3 CM 1/2 PO, Huiler LA Pompe OU Plus Gros

Page 8

Installation

 

 

 

8

1

Ne pas faire fonctionner

2

Tuyau souple de refoulement de

Do Not Run Pump Dry!

 

la pompe à sec!

 

1/2" or Larger

 

 

 

 

Outlet1,3 cm Hose(1/2 po) ou plus gros

 

 

 

 

 

Tuyau souple

 

 

 

 

 

d’aspiration

 

 

 

 

 

1/2" or Larger

Huile

ENTRÉE

 

 

 

renforcé de

 

OUT

 

Reinforced

 

 

 

 

 

1,3 cm (1/2 po)

 

 

 

 

 

Inlet Hose

 

 

 

SORTIE

IN

ou plus gros

 

 

 

 

 

 

 

 

de leau

 

 

 

 

Water OUT

 

 

 

 

 

ADMISSION

 

 

 

 

 

Water IN

 

 

 

 

 

de l’eau

 

 

 

IN

 

 

 

 

 

 

 

 

 

4837A 0205

 

UTILISER UN TUYAU SOUPLE

 

DE 1,3 CM (1/2 PO)

HUILER LA POMPE

(OU PLUS GROS)

Huiler la pompe avec 1/2 cuiller à soupe d’huile végétale de qualité alimentaire ou d’huile minérale chaque fois qu’on l’u- tilise. Verser l’huile dans l’orifice repéré «IN». Trois sachets d’huile de contenance de 1/2 cuiller à soupe chacun sont fournis.

AVIS : La pompe est lubrifiée par le liquide qu’elle pompe

NE PAS FAIRE FONCTIONNER LA POMPE À SEC!

Si la pompe n’a pas commencé à faire cir- culer l’eau dans 30 secondes ou moins, revérifier l’installation et la tuyauterie.

Monter la pompe fermement sur une plate- forme stable.

Utiliser un tuyau souple renforcé sur le côté admission. Cette pompe doit être installée à moins de 3 mètres (10 pieds) au-dessus de la source d’eau, et à moins de 7,6 mètres (25 pieds) d’un côté ou l’autre de la source d’eau. Le tuyau souple de refoulement doit être aussi court que possible, soit 7,6 mètres (25 pieds) de long maximum.

Veiller à ce que la rondelle dans la garni- ture d’admission soit hermétique. Si ce joint n’est pas étanche et cause des fuites d’air, la pompe ne fonctionnera pas.

Pour les services des pièces ou d'assistance, appeler le service à la clientèle Simer en composant le 1 (800) 468-7867

Image 8
Contents Model M40-04 Model M40P-04Simer Limited Warranty SafetySafety Information Installation OIL the PumpKeep the Hoses AS Straight AS Possible Performance Troubleshooting ChartUnplug the Pump Repair Parts Brush Installation Repair PartsGarantie limitée Simer SécuritéConsignes DE Sécurité DE 1,3 CM 1/2 PO Huiler LA Pompe OU Plus GrosGarder LES Tuyaux Souples Aussi Droits QUE Possible BONTableau DE Recherche DES Pannes Débrancher LA PompeRendement Pièces de rechange Pièces DE RechangeGarantia Limitada de Simer SeguridadInformación Sobre LA Seguridad USE UNA Manguera DE 1/2 O MayorAceite LA Bomba InstalaciónLA Manguera DE Admisión VA Dentro DEL Agua InstalaciónMantenga LAS Mangueras LO MÁS Rectas Posibles Cuadro DE Localización DE Fallas Desenchufe LA BombaDesempeño Repuestos Repuestos Instalación de escobillasModelos M40-04, M40P-04

M40-04, M40P-04 specifications

Simer Pumps has made a significant mark in the industry with the introduction of its M40P-04 and M40-04 models. These pumps are engineered to meet a wide variety of demanding applications, delivering reliability and performance that users can trust.

The Simer M40P-04 is designed with versatility in mind. It features a strong and durable construction that allows it to perform efficiently under varying conditions. The pump is powered by a robust motor that ensures high flow rates, making it suitable for applications in agriculture, building services, and general water transfer. The M40P-04 includes an integrated thermal overload protection system, which prevents motor overheating and ensures a longer lifespan.

On the other hand, the M40-04 model shares many of the same reliable traits as the M40P-04 but is optimized for slightly different use cases. It boasts a compact design that allows for easy installation in tight spaces while maintaining exceptional performance levels. This model is particularly well-suited for residential applications such as lawn irrigation systems and water features.

Both pumps utilize advanced technologies that enhance their operational efficiency. For instance, Simer has incorporated a high-quality impeller design in both models, which minimizes energy consumption while maximizing water flow. This design not only reduces operating costs but also makes them environmentally friendly.

In terms of characteristics, the M40P-04 comes with a built-in pressure switch, which automatically turns the pump on and off based on water demand, ensuring optimal performance and energy savings. Similarly, the M40-04 features a self-priming mechanism, allowing it to draw water from underground sources without the need for manual priming.

Durability is a key aspect of both models. They are constructed with corrosion-resistant materials, making them suitable for various water types, including those containing debris or sediments. This durability is complemented by easy maintenance features, allowing users to keep the pumps in optimal condition with minimal effort.

Ultimately, the Simer M40P-04 and M40-04 pumps stand out in the market for their reliability, innovative technology, and practical design. They are ideal choices for those seeking efficient, robust, and user-friendly pumping solutions for various applications. With their combination of power and efficiency, both models promise to deliver outstanding performance over time.