GDP-5H — LOAD APPLICATION/EARTH LEAKAGE BREAKER
Three Phase Load — 180 Hz
180 Hz, three phase, 230V, motor-in-head vibrators can be operated with this generator. When operating more than one concrete vibrator, the ON/OFF switch of each concrete vibrators shall be turned on one at a time.
If they are switched on simultaneously, the circuit breaker may trip or the engine may be overloaded.
The vibrators can be operated simultaneously if the total power consumption does not exceed the rated output of the generator (5.0 KVA).
How to Use
Always conduct the following in order that the earth leakage breaker will operate safely. Also, if the leakage breaker should for some reason actuate, first stop the generator and then repair or eliminate the source of the earth leakage before resetting the leakage breaker.When setting up the generator perform the following:
Ground the Generator
Ground the generator from its ground connector so that resistance to ground is 500 ohms or less.
| | If output (kVA) is not given on the |
| NOTE | vibrators nameplate, approximate output |
| may be determined by multiplying |
| |
| | voltage by amperage by | . |
Ground the Tool
Ground the tool (load) in the same manner as the generator.
Earth Leakage Breaker (180 Hz)
The earth leakage detection breaker (Figure 3) is used for
Simply because the generator is equipped with a earth leakage breaker does not mean that grounding of the load can be neglected, please be sure to properly ground load equipment.
180 Hz application (3-phase vibrators). Before operating the generator test this breaker to make sure that is functioning correctly.
For safety’s sake, the operation of the earth leakage breaker should be tested periodically according to the following procedure:
1.Start the engine and set it to high speed.
2.Turn the leakage breaker ON.
3.During normal operation, press the earth leakage indicator test button on the front of the generator and observe that indicator button pops out and the leakage breaker trips.
4.Push the indicator button back in when resetting.
Figure 3. Earth Leakage Breaker
Before operating generator press earth leakage test button.The earth leakage
NOTE breaker's earth leakage detection sensitivity is 30 mA, and the actuation time is 0.1 sec.
GDP-5H A.C. GENERATOR — PARTS & OPERATION MANUAL — REV. #2 (10/05/05) — PAGE 17
Model GDP-5H
Page
Heres HOW to GET Help
Table of Contents
When ordering parts Please supply the following information
Parts Ordering Procedures
Respiratory Hazards
Burn Hazards
Rotating Parts Hazards
Equipment Damage
Read this manual
GDP-5H Rules for Safe Operation
GDP-5H Rules for Safe Operation
Emergencies
Death
Operation and Safety Decals
Machine Safety Decals
Effects of Altitude and Heat
GDP-5H Specifications Generator
Specifications Engine
Dimensions
GDP-5H Dimensions
Generator
Phase Vibrator Application
Control Box
Excitation System
Extension Cables
Single Phase Load 60 Hz
GDP-5H Load Application
How to Use
Three Phase Load 180 Hz
Ground the Generator
Ground the Tool
GDP-5H Controls and Indicators
240V Full Power Switch
GDP-5H Controls and Indicators
FuelTank Fuel tank capacity is 5 gallons 19 liters
Generator Refueling
GDP-5H Generator Refueling
Outdoor Installation
GDP-5H Installation
Indoor Installation
Mounting
Connecting the Ground
GDP-5H Installation
Extension Cable
General Inspection Prior to Operation Ground Power Tools
GDP-5H PRE-INSPECTION
Before Starting
GDP-5H PRE-INSPECTION Engine
Engine Oil Check
Fuel Check
Choke Lever
180 Hz Circuit Breakers OFF Position Starting the Engine
GDP-5H Initial START-UP/GENERATOR Operation
Hz Output Receptacles
Connecting the Load
Generator Storage
Stopping the Engine
Engine Maintenance Schedule
GDP-5H Maintenance Engine
Engine Oil Draining
Spark Plug Gap
GDP-5H Wiring Diagram Generator S/N 5541049 and below
GDP-5H -WIRING Diagram Generator S/N 5543731 and Above
GDP-5H -TROUBLESHOOTING Engine
GDP-5H -TROUBLESHOOTING Engine
GDP-5H -TROUBLESHOOTING Generator
Page
GDP-5H Explanation of Code in Remarks Column
How to read the marks and remarks used in this parts
Items Found In the Remarks Column
Items Found In the Items Number Column
Description
To 3 Units
GDP-5H Nameplate and Decals
Part Name QTY Remarks
GDP-5H Nameplate and Decals
GDP-5H Generator Assy
SET Bolt Rotor
GDP-5H Control BOX Assy
Control BOX
GDP-5H Muffler Assy
GDP-5H Muffler Assy
GDP-5H Pipe Frame Assy
Pipe Frame
Honda GX340K1EDN2 Engine AIR Cleaner Assy
Part Name
Honda GX340K1EDN2 Engine Camshaft Assy
ROD, Push
Honda GX340K1EDN2 Engine Carburetor Assy
Gasket SET
Honda GX340K1EDN2 Engine Control Assy
ARM, Governor
Honda GX340K1EDN2 Engine Crankcase Cover Assy
GASKET, Case Cover
Honda GX340K1EDN2 Engine Crankshaft Assy
Part Name QTY. Remarks
Honda GX340K1EDN2 Engine Cylinder Barrel Assy
Switch ASSY., OIL Level
Honda GX340K1EDN2 Engine Cylinder Head Assy
Cylinder Head
Honda GX340K1EDN2 Engine FAN Cover Assy
COVER, FAN *NH1* Black
Honda GX340K1EDN2 Engine Flywheel Assy
FAN, Cooling
Honda GX340K1EDN2 Engine Ignition Coil Assy
Coil ASSY., Ignition
Honda GX340K1EDN2 Engine Piston Assy
Piston STD
Honda GX340K1EDN2 Engine Recoil Starter Assy
PULLEY, Recoil Starter
Honda GX340K1EDN2 Engine Solenoid Assy
SPRING, Choke Return
Honda GX340K1EDN2 Engine Labels Assy
Emblem
Effective October 1, 2002 Terms and Conditions of Sale Parts
Page
Your Local Dealer is