DCA-85USJ — RULES FOR SAFE OPERATION

Towing &Transporting Safety

To reduce the possibility of an accident while transporting the generator on public roads, always make sure the trailer that supports the generator and the towing vehicle are in good operating condition and both units are mechanically sound.

The following list of safety precautions should be followed when towing your generator:

CAUTION - FOLLOWTOWING REGULATIONS

Check with your local county or state safety towing regulations, in addition to meeting Department of Transportation (DOT) SafetyTowing Regulations, before towing your generator.

ALWAYS shutdown engine before transporting.

Tighten both fuel tank caps securely.

If generator is mounted on a trailer, make sure trailer complies with all local and state safety transportation laws. Follow the listed Towing & Transporting Safety guidelines for basic towing techniques.

Make sure the hitch and coupling of the towing vehicle are rated equal to, or greater than the trailer "gross vehicle weight rating.”

ALWAYS inspect the hitch and coupling for wear. NEVER tow a trailer with defective hitches, couplings, chains etc.

Check the tire air pressure on both towing vehicle and trailer. Trailer tires should be inflated to 50 psi cold. Also check the tire tread wear on both vehicles.

ALWAYS make sure the trailer is equipped with a "Safety Chain".

ALWAYS attach trailer’s safety chains to towing vehicle properly.

ALWAYS make sure the vehicle and trailer directional, backup, brake, and trailer lights are connected and working properly.

DOT Requirements include the following:

z Connect and test electric brake operation.

z Secure portable power cables in cable tray with tie wraps.

The maximum speed for highway towing is 55 MPH unless posted otherwise. Recommended off-road towing is not to exceed 15 MPH or less depending on type of terrain.

Place chock blocks underneath wheel to prevent rolling, while parked.

Use the trailer’s swivel jack to adjust the trailer height to a level position while parked.

Avoid sudden stops and starts.This can cause skidding, or jack-knifing. Smooth, gradual starts and stops will improve towing.

Avoid sharp turns.

Trailer should be adjusted to a level position at all times when towing.

Raise and lock trailer wheel stand in up position when transporting.

The maximum speed for highway towing is 55 MPH unless posted otherwise. Recommended off-road towing is not to exceed 15 MPH or less depending on type of terrain.

Place support blocks underneath the trailer’s bumper to prevent tipping, while parked.

Avoid sharp turns to prevent rolling.

DO NOT transport generator with fuel in tank.

Emergencies

ALWAYS know the location of the nearest fire extinguisher.

ALWAYS know the location of the nearest and first aid kit.

ALWAYS know the location of the nearest phone or keep a phone on the job site, in case of emergencies.

ALWAYS have easy access to the phone numbers of the nearest Ambulance, Doctor and Fire Department. This information will be invaluable in the case of an emergency.

DCA-85USJ — OPERATION AND PARTS MANUAL — REV. #0 (09/17/04) — PAGE 13

Image 13
Contents Model DCA-85USJ Parts List NO. M28704000042 DCA-85USJ Operation and Parts Manual REV. #0 09/17/04 Wilmington Ave Carson, CA Heres HOW to GET HelpTable of Contents When ordering parts Please supply the following information Parts Ordering ProceduresGenerator Specifications DCA-85USJ SpecificationsDCA-85USJ Dimensions TOP, Side and Front Hazard Symbols DCA85USJ Safety Message Alert SymbolsThis generator, other property, or DCA85USJ Safety Message Alert SymbolsDCA-85USJ Rules for Safe Operation General SafetyGenerator Grounding Electrical SafetyBattery Safety Maintenance SafetyEmergencies Towing &Transporting SafetyGenerator Decals DCA-85USJ Generator DecalsGenerator Decals Cont inued DCA-85USJ Generator DecalsTypical Generator Grounding Application DCA-85USJ InstallationIndoor Installation Outdoor InstallationWhen connecting the generator MountingEngine Operating Panel DCA-85USJ Series Familiarization GeneratorGenerator Control Panel Output Terminal PanelMajor Components DCA-85USJ Major Components20 DCA-85USJ Operation and Parts Manual REV. #0 09/17/04 Be switched off Ammeter phase-selector switchAdjustment of the generator’s output voltage OnlyDCA-85USJ Engine Operating Panel DCA-85USJ Engine Operating Panel Output Terminal Familiarization DCA-85USJ Output Terminal Panel FamiliarizationF.C.I. Receptacle 120VAC Gfci ReceptaclesBlower Fan Connecting LoadsThree Phase Load Single Phase LoadDCA-85USJ Load Application Motors and motor-drivenGenerator Amperage Voltage Selector SwitchGenerator OutputVoltages Gfci Receptacle Load CapabilityDCA-85USJ Gauge Reading How to Read the OutputTerminal GaugesReading Amperage DCA-85USJ Output Terminal Panel Connections Three-Phase PositionUvwo Terminal Output Voltages 3Ø 240/139 Output Terminal Lug Voltages1Ø 240V/120V Output Terminal Lug Voltages 3Ø 480/277 Output Terminal Lug VoltagesCircuit Breakers DCA-85USJ PRE-SETUPLubrication Oil Fuel CheckRefueling Refueling ProcedureAir Cleaner Fan BeltTension Cleaning the RadiatorOperation FreezingWeather Vol % Freezing PointBattery Cable Installation BatteryWiring AlternatorEngines exhaust contains harmful emissions Before StartingDirect exhaust away from nearby personnel Close all engine enclosure doors FigurePosition to start the engine Figure Starting ManualOil Pressure Gauge Place the Mpec Control Switch in the Auto position Starting Auto ModeShutdown Procedure DCA-85USJ Generator SHUT-DOWN ProcedureEmergency Shutdown Procedure DCA-85USJ Maintenance Check Oil Level Air RemovalReplacing Oil Filter Replacing Fuel FilterTo ensure adequate starting Battery chargerTrailer Maintenance DCA-85USJ -TRAILER MaintenanceBrake Adjustment DCA-85USJ -TRAILER MaintenanceBrakes Check the wheel and drum for free rotationTireWear/Inflation Tires/Wheels/Lug NutsSuspension Start all wheel lug nuts by hand Lug NutTorque RequirementsDCA-85USJ -TRAILERWIRING Diagram Generator Wiring Diagram DCA-85USJ Generatorwiring DiagramDCA-85USJ Enginewiring Diagram DCA-85USJ -TROUBLESHOOTING Generator Engine Controller Troubleshooting Mpec DCA-85USJ -TROUBLESHOOTING Engine ControllerDCA-85USJ Operation and Parts Manual REV. #0 09/17/04 Items Found In the Items Number Column Explanation of Code in Remarks ColumnIf more than one of the same DCA-85USJ Suggested Spare Parts Part number on this Suggested Spare Parts listDCA-85USJ Generator Assy 8101070033 B61100001020012810035 8101611004DCA-85USJ Control BOX Assy DCA-85USJ Control BOX Assy 60 DCA-85USJ Operation and Parts Manual REV. #0 09/17/04 PL-05 06021030920601810245 0602120096DCA-85USJ Engine & Radiator Assy 4045TF275 M29232000140602041292 RE50483664 DCA-85USJ Operation and Parts Manual REV. #0 09/17/04 0602022561 06020225630603306590 0603300285DCA-85USJ Outputterminal Assy M9220100304 M3230700003M9220100404 0039316000DCA-85USJ Battery Assy 627MFD 0602220187M9310500014 M9103000304DCA-85USJ Muffler Assy 0017112030 M2330100703M2333000703 M2333200204DCA-85USJ Fueltank Assy 0605505070 M23630009020605501073 0605516090DCA-85USJ Enclosure #1 Assy M2363300203 M24130015020603306797 M242300070276 DCA-85USJ Operation and Parts Manual REV. #0 09/17/04 24A M2493103404 M2423201203M3433000803 M3433000813DCA-85USJ Enclosure #2 Assy M3443000812 M34430008028400021~ M349330320380 DCA-85USJ Operation and Parts Manual REV. #0 09/17/04 18A M2493404704 M2453001703M2453001803 19A M2493405104DCA-85USJ Rubber Seals Assy 0229201130 02292008700229201240 0228900660DCA-85USJ Name Plate Assy M15000070 M15000020M25000050 M2520001086 DCA-85USJ Operation and Parts Manual REV. #0 09/17/04 M9520100304 M9520100204M9520100404 M9520100503Freightpolicy Terms and Conditions of Sale PartsDCA-85USJ Operation and Parts Manual REV. #0 09/17/04 Your Local Dealer is