Multiquip DCA400SSI manual Frequency Meter

Page 35

GENERATOR START-UP PROCEDURE (MANUAL)

6.The generator’s frequency meter (Figure 42) should be displaying the 60 cycle output frequency in HERTZ.

Figure 42. Frequency Meter

7.The generator’s AC-voltmeter (Figure 43) will display the generator’s output in VOLTS. If the voltage is not within the specified tolerance, use the voltage adjustment control knob (Figure 44) to increase or decrease the desired voltage.

Figure 43. Voltmeter

Figure 44. Voltage Adjust Control Knob

8.The ammeter (Figure 45) will indicate zero amps with no load applied. When a load is applied, the ammeter will indicate the amount of current that the load is drawing from the generator.

Figure 45. Ammeter (No Load)

9.The engine oil pressure gauge (Figure 46) will indicate the oil pressure of the engine. Under normal operating conditions the oil pressure is approximately 28 to 85 psi. (193~586 kPa).

Figure 46. Oil Pressure Gauge

10.The coolant temperature gauge (Figure 47) will indicate the coolant temperature. Under normal operating conditions the coolant temperature should be between 167°~203°F (75°~95°C) (Green Zone).

Figure 47. Coolant Temperature Gauge

11.The tachometer gauge (Figure 48) will indicate the speed of the engine when the generator is operating. Under normal operating conditions this speed is approximately 1800 RPM’s.

Figure 48. Engine Tachometer Gauge

12.Place the main, GFCI, and aux. circuit breakers in the ON position (Figure 49).

Figure 49. Main, Aux. and GFCI

Circuit Breakers (ON)

13.Observe the generator’s ammeter (Figure 50) and verify it reads the anticipated amount of current with respect to the load. The ammeter will only display a current reading if a load is in use.

Figure 50. Ammeter (Load)

14.The generator will run until manually stopped or an abnormal condition occurs.

DCA400SSI GENERATOR • OPERATION AND PARTS MANUAL — REV. #2 (11/03/08) — PAGE 35

Image 35
Contents This Manual Must Accompany the Equipment AT ALL Times Model DCA400SSIProposition 65 Warning Administrator Reporting Safety DefectsDCA400SSI Generator Table of ContentsOrdering parts has never been easier Parts Ordering ProceduresSafety Messages Safety Information Always know the location of the nearest General SafetyGenerator Safety Before servicing equipment Engine SafetyTowing Safety Fuel Safety The electrical voltage required to Electrical SafetyGrounding Safety Power Cord/Cable SafetyEnvironmental Safety Battery SafetyDCA400SSI SpecificationsDimensions DimensionsTypical Generator Grounding Application InstallationGenerator Grounding Outdoor InstallationIndoor Installation MountingGeneral Information Item no Major ComponentsPilot Lamp Indicates the system is running Generator Control PanelOwing from the U,V, and W Output Terminal Lugs to the load Engine Operating Panel Air Filter Alarm When the air fi lterPage Terminal legs O and Ground are considered bonded grounds Output Terminal Panel FamiliarizationOutput Terminal Familiarization 240V Twist-Lock Auxiliary Receptacles VAC Gfci ReceptaclesOver Current Relay Connecting LoadsLoad Application Single Phase LoadThree Phase Load Generator Amperage Generator OutputsGenerator Output Voltages Voltage Change-Over BoardMaximum Amps Generator OUTPUTS/GAUGE Reading1Ø-240V Uvwo Terminal Output Voltages Output Terminal Panel ConnectionsUvwo Terminal Output Voltages 3Ø-240V Uvwo Terminal Output Voltages1Ø-277V Uvwo Terminal Output Voltages 3Ø-480V Uvwo Terminal Output Voltages1Ø-480V Uvwo Terminal Output Voltages Fuel Check INSPECTION/SETUPCircuit Breakers Lubrication OILOnly use #2 diesel fuel when refueling Refueling ProcedureOperation in Freezing Weather Cleaning the RadiatorAIR Cleaner FAN Belt Tension Coolant ANTIFREEZE/SUMMER COOLANT/ WaterAlternator BatteryBattery Cable Installation WiringStarting Manual Generator START-UP Procedure ManualPlace the engine speed switch in the LOW down position Before StartingFrequency Meter Place the engine speed switch in the High position Generator START-UP Procedure Auto ModeStarting Auto Mode Before connecting this generator to anyNever stop the engine suddenly except in an emergency Generator SHUT-DOWN ProceduresNormal Shutdown Procedure Emergency Shutdown ProcedureAir Cleaner with Dust Indicator MaintenanceGeneral Inspection AIR Cleaner AIR Removal Fuel AdditionFuel Tank Inspection Flushing OUT Radiator and Replacing Coolant Radiator CleaningCheck OIL Level Replacing Oil FilterCharger Not used for long periods of time, apply power toCoupler Type of hitch used on the trailer for towing Trailer MaintenanceTrailer Maintenance Actuator Brake AdjustmentBrakes Hydraulic Surge BrakesSuspension TIRES/WHEELS/LUG NutsTire Wear/Inflation Never use an pneumatic air gun to tighten wheel lug nuts Lug Nut Torque RequirementsTrailer/Towing Vehicle Wiring Diagram Trailer Wiring DiagramGenerator Wiring Diagram Generator Wiring DiagramEngine Wiring Diagram Engine Wiring DiagramController Wiring Diagram Controller Wiring DiagramTroubleshooting Generator Adjust governor controller Troubleshooting Engine ControllerClean/repair radiator grill Adjust governor actuatorMethod of Operation Troubleshooting Diagnostic LampPage Explanation of Code in Remarks Column Sample Parts ListTo 3 units Suggested Spare PartsGenerator Assy 0040005000 06018424010601823282 0018205020Generator Assy C3154400003 001010606013A 0040006000 13B 0041206000Engine Operating Panel Assy 0021008080 C33511006030207006000 1823200010Control BOX Assy 0601807514 C32130028020601801170 0027106016Control BOX Assy 8121468300 89446070600601815154 0027104016Control BOX Assy 0017110035 82218148048224117004 C3213400604Engine and Radiator Assy 8980088400 C39232001941132402330 1132402410Engine and Radiator Assy 44A 0207010000 06020407790602040582 C3373200004Output Terminal Assy 0039320000 C2231700403C0277500004 0801830904Battery Assy 0805006504 0165721052C9109100704 0805007804Muffler Assy C3333001903 C33301004020019110025 0047010030Fuel Tank ASSY. S/N 3813334 and below 0264100525 C33630025030845500104 0810105400Fuel Tank ASSY. S/N 3813335 and Above 0131506000 0130406000 Joint 1/2 0130206000C3366704804 Enclosure #1 Assy Base Enclosure #2 Assy Rear Frame Enclosure #3 Assy Splasher Panel Enclosure #3 Assy 0845046904 Rubber Seals Assy 0229201400 Nameplate and Decals Assy Control BOX Group Nameplate and Decals Assy Battery Group Freight Policy Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help
Related manuals
Manual 4 pages 63.04 Kb

DCA400SSI specifications

The Multiquip DCA400SSI is a robust and versatile generator designed for various demanding applications, particularly in construction and industrial settings. This powerful unit is part of Multiquip’s premium line of portable generators, known for their reliability and efficiency.

At the heart of the DCA400SSI is a formidable 400 kW diesel engine that provides exceptional power output while maintaining optimal performance. The generator features a highly efficient cooling system that ensures the engine operates within safe temperature ranges, thus extending its lifespan. Additionally, the DCA400SSI integrates sound attenuation technology that minimizes noise levels, making it suitable for use in noise-sensitive environments such as residential areas or during night-time operations.

One of the standout features of the DCA400SSI is its advanced digital controller. This state-of-the-art technology offers enhanced monitoring and control capabilities, allowing users to easily adjust settings and monitor essential parameters such as voltage, frequency, and running hours. The digital controller includes protective features that safeguard the engine against potential damage, thereby enhancing reliability during operation.

The DCA400SSI also emphasizes user-friendliness. Its intuitive control panel and easy-to-read displays ensure that operators can quickly understand and manage the generator's functions. This is particularly important in emergency situations or during critical operations when time is of the essence. The generator is designed with mobility in mind, equipped with heavy-duty wheels and a sturdy frame, allowing for easy transportation across job sites.

In terms of fuel efficiency, the DCA400SSI stands out with an extended fuel tank that supports longer operation times between refueling. This characteristic is crucial for operations that require continuous power supply without interruptions. The unit’s fuel efficiency is complemented by its eco-friendly emissions level, adhering to stringent environmental regulations, which is vital for contractors seeking sustainable solutions.

Overall, the Multiquip DCA400SSI is engineered to deliver high performance, reliability, and user-friendly operation. Its combination of advanced technologies, operational efficiency, and robust construction makes it an ideal choice for any job that demands dependable power. Whether for construction, industrial applications, or emergency backup, the DCA400SSI continues to reinforce Multiquip's reputation for quality and innovation in the generator market.