Multiquip DCA400SSI C3330100402, 0019110025, 0047010030, C3333001903, C9304000304, C3334200804

Page 77

 

 

 

 

MUFFLER ASSY.

NO.

PART NO.

PART NAME

QTY.

REMARKS

1

C3330100402

MUFFLER

1

 

2

0019110025

HEX HEAD BOLT

4

 

2A

0042310000

WASHER, LOCK

4

 

2B

0047010030

WASHER, FLAT

4

 

3

C3333001903

EXHAUST PIPE

1

 

4

C9304000304

GASKET

1

 

5

C3334200804

GASKET

1

 

6

0010316060

HEX HEAD BOLT

8

 

6A

0030316000

HEX NUT

8

 

6B

0042516000

WASHER, LOCK

8

 

6C

0041616000

WASHER, FLAT

16

 

7

0010316060

HEX HEAD BOLT

4

 

7A

0030016000

HEX NUT

4

 

7B

0042516000

WASHER, LOCK

4

 

7C

0041616000

WASHER, FLAT

8

 

8

C3333302104

BRACKET

1

 

9

0017108020

HEX HEAD BOLT

4

 

10

0602326065

U- BOLT

1

 

11

C3331300404

COVER

2

 

12

0019208020

HEX HEAD BOLT

4

 

DCA400SSI GENERATOR • OPERATION AND PARTS MANUAL — REV. #2 (11/03/08) — PAGE 77

Image 77
Contents This Manual Must Accompany the Equipment AT ALL Times Model DCA400SSIProposition 65 Warning Administrator Reporting Safety DefectsDCA400SSI Generator Table of ContentsOrdering parts has never been easier Parts Ordering ProceduresSafety Messages Safety Information Always know the location of the nearest General SafetyGenerator Safety Before servicing equipment Engine SafetyTowing Safety Fuel SafetyGrounding Safety Electrical SafetyPower Cord/Cable Safety  The electrical voltage required toEnvironmental Safety Battery SafetyDCA400SSI SpecificationsDimensions DimensionsTypical Generator Grounding Application InstallationIndoor Installation Outdoor InstallationMounting Generator GroundingGeneral Information Item no Major ComponentsPilot Lamp Indicates the system is running Generator Control PanelOwing from the U,V, and W Output Terminal Lugs to the load Engine Operating Panel Air Filter Alarm When the air fi lterPage Terminal legs O and Ground are considered bonded grounds Output Terminal Panel FamiliarizationOutput Terminal Familiarization 240V Twist-Lock Auxiliary Receptacles VAC Gfci ReceptaclesOver Current Relay Connecting LoadsLoad Application Single Phase LoadThree Phase Load Generator Output Voltages Generator OutputsVoltage Change-Over Board Generator AmperageMaximum Amps Generator OUTPUTS/GAUGE ReadingUvwo Terminal Output Voltages Output Terminal Panel Connections3Ø-240V Uvwo Terminal Output Voltages 1Ø-240V Uvwo Terminal Output Voltages1Ø-277V Uvwo Terminal Output Voltages 3Ø-480V Uvwo Terminal Output Voltages1Ø-480V Uvwo Terminal Output Voltages Circuit Breakers INSPECTION/SETUPLubrication OIL Fuel CheckOnly use #2 diesel fuel when refueling Refueling ProcedureAIR Cleaner FAN Belt Tension Cleaning the RadiatorCoolant ANTIFREEZE/SUMMER COOLANT/ Water Operation in Freezing WeatherBattery Cable Installation BatteryWiring AlternatorPlace the engine speed switch in the LOW down position Generator START-UP Procedure ManualBefore Starting Starting ManualFrequency Meter Starting Auto Mode Generator START-UP Procedure Auto ModeBefore connecting this generator to any Place the engine speed switch in the High positionNormal Shutdown Procedure Generator SHUT-DOWN ProceduresEmergency Shutdown Procedure Never stop the engine suddenly except in an emergencyAir Cleaner with Dust Indicator MaintenanceGeneral Inspection AIR Cleaner AIR Removal Fuel AdditionFuel Tank Inspection Check OIL Level Radiator CleaningReplacing Oil Filter Flushing OUT Radiator and Replacing CoolantCharger Not used for long periods of time, apply power toCoupler Type of hitch used on the trailer for towing Trailer MaintenanceTrailer Maintenance Brakes Brake AdjustmentHydraulic Surge Brakes ActuatorSuspension TIRES/WHEELS/LUG NutsTire Wear/Inflation Never use an pneumatic air gun to tighten wheel lug nuts Lug Nut Torque RequirementsTrailer/Towing Vehicle Wiring Diagram Trailer Wiring DiagramGenerator Wiring Diagram Generator Wiring DiagramEngine Wiring Diagram Engine Wiring DiagramController Wiring Diagram Controller Wiring DiagramTroubleshooting Generator Clean/repair radiator grill Troubleshooting Engine ControllerAdjust governor actuator Adjust governor controllerMethod of Operation Troubleshooting Diagnostic LampPage Explanation of Code in Remarks Column Sample Parts ListTo 3 units Suggested Spare PartsGenerator Assy 0601823282 06018424010018205020 0040005000Generator Assy 13A 0040006000 001010606013B 0041206000 C3154400003Engine Operating Panel Assy 0207006000 C33511006031823200010 0021008080Control BOX Assy 0601801170 C32130028020027106016 0601807514Control BOX Assy 0601815154 89446070600027104016 8121468300Control BOX Assy 8224117004 8221814804C3213400604 0017110035Engine and Radiator Assy 1132402330 C39232001941132402410 8980088400Engine and Radiator Assy 0602040582 0602040779C3373200004 44A 0207010000Output Terminal Assy C0277500004 C22317004030801830904 0039320000Battery Assy C9109100704 01657210520805007804 0805006504Muffler Assy 0019110025 C33301004020047010030 C3333001903Fuel Tank ASSY. S/N 3813334 and below 0845500104 C33630025030810105400 0264100525Fuel Tank ASSY. S/N 3813335 and Above 0131506000 0130406000 Joint 1/2 0130206000C3366704804 Enclosure #1 Assy Base Enclosure #2 Assy Rear Frame Enclosure #3 Assy Splasher Panel Enclosure #3 Assy 0845046904 Rubber Seals Assy 0229201400 Nameplate and Decals Assy Control BOX Group Nameplate and Decals Assy Battery Group Freight Policy Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help
Related manuals
Manual 4 pages 63.04 Kb

DCA400SSI specifications

The Multiquip DCA400SSI is a robust and versatile generator designed for various demanding applications, particularly in construction and industrial settings. This powerful unit is part of Multiquip’s premium line of portable generators, known for their reliability and efficiency.

At the heart of the DCA400SSI is a formidable 400 kW diesel engine that provides exceptional power output while maintaining optimal performance. The generator features a highly efficient cooling system that ensures the engine operates within safe temperature ranges, thus extending its lifespan. Additionally, the DCA400SSI integrates sound attenuation technology that minimizes noise levels, making it suitable for use in noise-sensitive environments such as residential areas or during night-time operations.

One of the standout features of the DCA400SSI is its advanced digital controller. This state-of-the-art technology offers enhanced monitoring and control capabilities, allowing users to easily adjust settings and monitor essential parameters such as voltage, frequency, and running hours. The digital controller includes protective features that safeguard the engine against potential damage, thereby enhancing reliability during operation.

The DCA400SSI also emphasizes user-friendliness. Its intuitive control panel and easy-to-read displays ensure that operators can quickly understand and manage the generator's functions. This is particularly important in emergency situations or during critical operations when time is of the essence. The generator is designed with mobility in mind, equipped with heavy-duty wheels and a sturdy frame, allowing for easy transportation across job sites.

In terms of fuel efficiency, the DCA400SSI stands out with an extended fuel tank that supports longer operation times between refueling. This characteristic is crucial for operations that require continuous power supply without interruptions. The unit’s fuel efficiency is complemented by its eco-friendly emissions level, adhering to stringent environmental regulations, which is vital for contractors seeking sustainable solutions.

Overall, the Multiquip DCA400SSI is engineered to deliver high performance, reliability, and user-friendly operation. Its combination of advanced technologies, operational efficiency, and robust construction makes it an ideal choice for any job that demands dependable power. Whether for construction, industrial applications, or emergency backup, the DCA400SSI continues to reinforce Multiquip's reputation for quality and innovation in the generator market.