Multiquip operation manual DCA-220SSVU Rules for Safe Operation, General Safety

Page 10

DCA-220SSVU — RULES FOR SAFE OPERATION

DANGER - READTHIS MANUAL!

Failure to follow instructions in this manual may lead to serious injury or even DEATH! This equipment is to be operated by trained and qualified personnel only! This equipment is for industrial use only.

The following safety guidelines should always be used when operating the DCA-220SSVUWhisperwatt™ AC Generator.

General Safety:

DO NOT operate or service this equipment before reading this entire manual.

The operator MUST BE familiar with proper safety precautions and operations techniques before using generator.

This equipment should not be operated by persons under 18 years of age.

NEVER operate this equipment without proper protective clothing, shatterproof glasses, steel-toed boots and other protective devices required by the job.

NEVER operate this equipment when not feeling well due to fatigue, illness or taking medicine.

NEVER operate this equipment under the influence or drugs or alcohol.

NEVER use accessories or attachments, which are not recommended by MQ Power for this equipment. Damage to the equipment and/or injury to user may result.

Manufacturer does not assume responsibility for any accident due to equipment modifications. Unauthorized equipment modification will void all warranties.

Whenever necessary, replace nameplate, operation and safety decals when they become difficult read.

ALWAYS check the machine for loosened threads or bolts before starting.

NEVER operate the generator in an explosive atmosphere or near combustible materials. An explosion or fire could result causing severe bodily harm or even death.

NEVER touch the hot exhaust manifold, muffler or cylinder. Allow these parts to cool before servicing engine or generator.

HighTemperatures – Allow the engine

to cool before performing service and maintenance functions. Contact with hot! components can cause serious burns.

The engine of this generator requires an adequate free flow of cooling air. NEVER operate the generator in any enclosed or narrow area where free flow of the air is restricted. If the air flow is

restricted it will cause serious damage to the generator or engine and may cause injury to people. The generator engine gives off DEADLY carbon monoxide gas.

DO NOT place hands or fingers inside generator engine compartment when engine is running.

NEVER run engine without air filter.Severe engine damage may occur.

DO NOT leave the generator running in the manual mode unattended.

Refer to the VOLVO Engine Owner's Manual for engine technical questions or information.

ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children.

PAGE 10 — DCA-220SSVU— OPERATION AND PARTS MANUAL — REV. #1 (01/20/06)

Image 10
Contents Parts List NO. M4870300024A Model DCA-220SSVU2 DCA-220SSVU- Operation and Parts Manual REV. #1 01/20/06 Heres HOW to GET Help Table of Contents Parts Ordering Procedures When ordering parts Please supply the following informationDCA-220SSVU Specifications DCA-220SSVU Dimensions TOP, Side and Front DimensionsDCA-220SSVU Safety Message Alert Symbols Hazard SymbolsDCA-220SSVU Safety Message Alert Symbols General Safety DCA-220SSVU Rules for Safe OperationDCA-220SSVU Rules for Safe Operation Electrical SafetyGenerator Grounding Maintenance Safety Battery SafetyTowing &Transporting Safety EmergenciesDCA-220SSVU Generator Decals DCA-220SSVU Generator Decals Generator Decals Cont inuedDCA-220SSVU Installation Typical Generator Grounding ApplicationIndoor Installation DCA-220SSVU InstallationOutdoor Installation MountingGenerator Control Panel GeneratorEngine Operating Panel Output Terminal PanelDCA-220SSVU Major Components Major Components20 DCA-220SSVU- Operation and Parts Manual REV. #1 01/20/06 DCA-220SSVU Generator Control Panel DCA-220SSVU Engine Operating Panel DCA-220SSVU Engine Operating Panel Auto On/Off Engine Controller MpecDCA-220SSVU Output Terminal Panel Familiarization Output Terminal FamiliarizationDCA-220SSVU Output Terminal Panel Familiarization 100VAC Gfci ReceptaclesConnecting Loads Over Current RelayThree Phase Load Single Phase LoadDCA-220SSVU Load Application Voltage Change-Over Board Generator OutputVoltagesGenerator Amperage DCA-220SSVU Generator OUTPUTS/ Gauge Reading How to Read the Output Terminal GaugeChange-Over Switch Maximum Amps3Ø-240V Uvwo Terminal Output Voltages DCA-220SSVU Output Terminal Panel ConnectionsUvwo Terminal Output Voltages 1Ø-240V Uvwo Terminal Output Voltages1Ø-480V Uvwo Terminal Output Voltages DCA-220SSVU Output Terminal Panel Connections3Ø-480V Uvwo Terminal Output Voltages 1Ø-277V Uvwo Terminal Output VoltagesLubrication Oil DCA-220SSVU PRE-SETUPCircuit Breakers Fuel CheckRefueling Procedure RefuelingOperation FreezingWeather Cleaning the RadiatorAir Cleaner Fan Belt Tension Must be less than 50%Wiring BatteryBattery Cable Installation AlternatorBefore Starting DCA-220SSVU Generator START-UP Procedure ManualStarting Manual Coolant Temperature Gauge No LoadStarting Auto Mode Mpec Control Switch AutoNormal Shutdown Procedure Emergency Shutdown ProcedureDCA-220SSVU Maintenance Check Oil Level Cleaning the Fuel StrainerAir Removal Replacing Oil FilterTo ensure adequate starting DCA-220SSVU -TRAILER Maintenance Trailer MaintenanceBrakes Brake AdjustmentHydraulic Surge Brakes TireWear/Inflation Tires/Wheels/Lug NutsSuspension DCA-220SSVU -TRAILER Maintenance Lug Nut Torque RequirementsDCA-220SSVU -TRAILERWIRING Diagram Trailer/Towing Vehicle Wiring DiagramDCA-220SSVU Generatorwiring Diagram Generator Wiring DiagramDCA-220SSVU Enginewiring Diagram Engine Wiring DiagramDCA-220SSVU -TROUBLESHOOTING Generator Generator TroubleshootingDCA-220SSVU -TROUBLESHOOTING Engine Controller Engine Controller Troubleshooting MpecSample Parts List DCA-220SSVU Explanation of Code in Remarks ColumnDCA-220SSVU Suggested Spare Parts DescriptionDCA-220SSVU Generator Assy Part Name QTY Remarks DCA-220SSVU Generator ASSY. Part Name QTY DCA-220SSVU- Control Panel Assy DCA-220SSVU- Control Panel Assy KnobDCA-220SSVU- Control BOX Assy Part Name DCA-220SSVU- Control BOX ASSY. LY2DUS24VDC DCA-220SSVU- Engine and Radiator Assy Breather Pipe 66 DCA-220SSVU- Operation and Parts Manual REV. #1 01/20/06 Hose Band DCA-220SSVU- Outputterminal Assy Output Terminal AssyTerminal Board DCA-220SSVU- Battery Assy Battery DCA-220SSVU- Muffler Assy Muffler DCA-220SSVU- Fueltank Assy Fuel Tank DCA-220SSVU- Enclosure Assy Enclosure AssyBase DCA-220SSVU- Enclosure ASSY. Enclosure ASSY.Hinge DCA-220SSVU- Rubber Seals Assy Seal Rubber DCA-220SSVU- Nameplate and Decals Assy Battery Group Terms and Conditions of Sale Parts FreightpolicyDCA-220SSVU- Operation and Parts Manual REV. #1 01/20/06 Your Local Dealer is
Related manuals
Manual 86 pages 979 b Manual 84 pages 27.37 Kb

DCA-220SSVU specifications

The Multiquip DCA-220SSVU is a robust and versatile generator, designed for both commercial and industrial applications. It is particularly renowned for its reliability, efficiency, and advanced features tailored to meet the demands of various worksites.

At its core, the DCA-220SSVU is a silent diesel generator, powered by a dependable Yanmar engine. This engine not only provides impressive performance but also ensures durability, making it a popular choice for operations that require continuous power supply. With a power output capacity of 220 kVA, this generator can effortlessly handle heavy-duty equipment and multiple power needs simultaneously.

One of the standout features of the DCA-220SSVU is its sound attenuation technology. Enclosed in a weather-proof canopy, the generator significantly minimizes noise output, making it an ideal option for locations with strict noise regulations, such as residential areas or sensitive environments. The generator operates at a low noise level, allowing it to blend seamlessly into various settings without causing disruption.

The Multiquip DCA-220SSVU also boasts advanced fuel efficiency. It is engineered to consume lesser fuel while providing maximum output, leading to reduced operational costs for users. This efficiency not only helps in cost savings but also minimizes the environmental impact, aligning with contemporary sustainability practices.

Another characteristic that sets the DCA-220SSVU apart is its user-friendly operation. The generator comes equipped with a digital control panel that displays critical information, including voltage, frequency, and runtime. This feature enables operators to monitor performance easily and perform quick troubleshooting when necessary.

Safety is paramount with the DCA-220SSVU, which is equipped with various protective features. These include low oil pressure shutdown, high coolant temperature shutdown, and overcurrent protection, ensuring that the generator operates safely and efficiently under varying load conditions.

Additionally, the generator features a large fuel tank that allows for extended run times, making it suitable for long-term projects or emergency situations. The DCA-220SSVU is engineered for enhanced mobility, thanks to its sturdy frame and integrated lifting points, allowing it to be transported easily across different job sites.

In conclusion, the Multiquip DCA-220SSVU is a powerful, efficient, and quiet generator that incorporates advanced technologies, comprehensive safety features, and user-friendly controls. Ideal for contractors and businesses looking for reliable power solutions, this generator exemplifies Multiquip's commitment to quality and innovation in the construction and industrial sectors.