Multiquip DCA-220SSVU operation manual Normal Shutdown Procedure, Emergency Shutdown Procedure

Page 39

DCA-220SSVU — GENERATOR SHUT-DOWN PROCEDURES

WARNING - SHUTTING DOWNTHE GENERATOR

NEVER stop the engine suddenly except in an emergency.

Normal Shutdown Procedure

To shutdown the generator use the following procedure:

1.Place both the MAIN, GFCI and LOAD circuit breakers as shown in Figure 38 to the OFF position.

2.Place the engine speed switch (Figure 56) in the “LOW ” (down) position.

Figure 56. Engine Speed Switch (Low)

3.Let the engine cool by running it at low speed for 3-5 minutes with no load applied.

4.Place the MPEC Control Switch (Figure 57) to the OFF/RESET position.

Figure 57. MPEC Control Switch (Off/Reset)

5.Verify that the all status LED on the MPEC display are OFF (not lit).

6.Remove all loads from the generator.

7.Inspect entire generator for any damage or loosening of components that may have occured during operation.

Emergency Shutdown Procedure

1.To shut-down the engine in the event of an emergency, switch the MAIN, GFCI and LOAD (Figure 38) circuit breakers to OFF position.

2.Place the MPEC Control Switch switch (Figure 57) to the OFF/RESET position.

DCA-220SSVU— OPERATION AND PARTS MANUAL — REV. #1 (01/20/06) — PAGE 39

Image 39
Contents Model DCA-220SSVU Parts List NO. M4870300024A2 DCA-220SSVU- Operation and Parts Manual REV. #1 01/20/06 Heres HOW to GET Help Table of Contents When ordering parts Please supply the following information Parts Ordering ProceduresDCA-220SSVU Specifications Dimensions DCA-220SSVU Dimensions TOP, Side and FrontHazard Symbols DCA-220SSVU Safety Message Alert SymbolsDCA-220SSVU Safety Message Alert Symbols DCA-220SSVU Rules for Safe Operation General SafetyElectrical Safety DCA-220SSVU Rules for Safe OperationGenerator Grounding Battery Safety Maintenance SafetyEmergencies Towing &Transporting SafetyDCA-220SSVU Generator Decals Generator Decals Cont inued DCA-220SSVU Generator DecalsTypical Generator Grounding Application DCA-220SSVU InstallationMounting DCA-220SSVU InstallationOutdoor Installation Indoor InstallationOutput Terminal Panel GeneratorEngine Operating Panel Generator Control PanelMajor Components DCA-220SSVU Major Components20 DCA-220SSVU- Operation and Parts Manual REV. #1 01/20/06 DCA-220SSVU Generator Control Panel DCA-220SSVU Engine Operating Panel Auto On/Off Engine Controller Mpec DCA-220SSVU Engine Operating PanelOutput Terminal Familiarization DCA-220SSVU Output Terminal Panel Familiarization100VAC Gfci Receptacles DCA-220SSVU Output Terminal Panel FamiliarizationOver Current Relay Connecting LoadsSingle Phase Load Three Phase LoadDCA-220SSVU Load Application Generator OutputVoltages Voltage Change-Over BoardGenerator Amperage Maximum Amps How to Read the Output Terminal GaugeChange-Over Switch DCA-220SSVU Generator OUTPUTS/ Gauge Reading1Ø-240V Uvwo Terminal Output Voltages DCA-220SSVU Output Terminal Panel ConnectionsUvwo Terminal Output Voltages 3Ø-240V Uvwo Terminal Output Voltages1Ø-277V Uvwo Terminal Output Voltages DCA-220SSVU Output Terminal Panel Connections3Ø-480V Uvwo Terminal Output Voltages 1Ø-480V Uvwo Terminal Output VoltagesFuel Check DCA-220SSVU PRE-SETUPCircuit Breakers Lubrication OilRefueling Refueling ProcedureMust be less than 50% Cleaning the RadiatorAir Cleaner Fan Belt Tension Operation FreezingWeatherAlternator BatteryBattery Cable Installation WiringDCA-220SSVU Generator START-UP Procedure Manual Before StartingStarting Manual No Load Coolant Temperature GaugeMpec Control Switch Auto Starting Auto ModeEmergency Shutdown Procedure Normal Shutdown ProcedureDCA-220SSVU Maintenance Replacing Oil Filter Cleaning the Fuel StrainerAir Removal Check Oil LevelTo ensure adequate starting Trailer Maintenance DCA-220SSVU -TRAILER MaintenanceBrake Adjustment BrakesHydraulic Surge Brakes Tires/Wheels/Lug Nuts TireWear/InflationSuspension Lug Nut Torque Requirements DCA-220SSVU -TRAILER MaintenanceTrailer/Towing Vehicle Wiring Diagram DCA-220SSVU -TRAILERWIRING DiagramGenerator Wiring Diagram DCA-220SSVU Generatorwiring DiagramEngine Wiring Diagram DCA-220SSVU Enginewiring DiagramGenerator Troubleshooting DCA-220SSVU -TROUBLESHOOTING GeneratorEngine Controller Troubleshooting Mpec DCA-220SSVU -TROUBLESHOOTING Engine ControllerDCA-220SSVU Explanation of Code in Remarks Column Sample Parts ListDescription DCA-220SSVU Suggested Spare PartsDCA-220SSVU Generator Assy Part Name QTY Remarks DCA-220SSVU Generator ASSY. Part Name QTY DCA-220SSVU- Control Panel Assy Knob DCA-220SSVU- Control Panel AssyDCA-220SSVU- Control BOX Assy Part Name DCA-220SSVU- Control BOX ASSY. LY2DUS24VDC DCA-220SSVU- Engine and Radiator Assy Breather Pipe 66 DCA-220SSVU- Operation and Parts Manual REV. #1 01/20/06 Hose Band Output Terminal Assy DCA-220SSVU- Outputterminal AssyTerminal Board DCA-220SSVU- Battery Assy Battery DCA-220SSVU- Muffler Assy Muffler DCA-220SSVU- Fueltank Assy Fuel Tank Enclosure Assy DCA-220SSVU- Enclosure AssyBase Enclosure ASSY. DCA-220SSVU- Enclosure ASSY.Hinge DCA-220SSVU- Rubber Seals Assy Seal Rubber DCA-220SSVU- Nameplate and Decals Assy Battery Group Freightpolicy Terms and Conditions of Sale PartsDCA-220SSVU- Operation and Parts Manual REV. #1 01/20/06 Your Local Dealer is
Related manuals
Manual 86 pages 979 b Manual 84 pages 27.37 Kb

DCA-220SSVU specifications

The Multiquip DCA-220SSVU is a robust and versatile generator, designed for both commercial and industrial applications. It is particularly renowned for its reliability, efficiency, and advanced features tailored to meet the demands of various worksites.

At its core, the DCA-220SSVU is a silent diesel generator, powered by a dependable Yanmar engine. This engine not only provides impressive performance but also ensures durability, making it a popular choice for operations that require continuous power supply. With a power output capacity of 220 kVA, this generator can effortlessly handle heavy-duty equipment and multiple power needs simultaneously.

One of the standout features of the DCA-220SSVU is its sound attenuation technology. Enclosed in a weather-proof canopy, the generator significantly minimizes noise output, making it an ideal option for locations with strict noise regulations, such as residential areas or sensitive environments. The generator operates at a low noise level, allowing it to blend seamlessly into various settings without causing disruption.

The Multiquip DCA-220SSVU also boasts advanced fuel efficiency. It is engineered to consume lesser fuel while providing maximum output, leading to reduced operational costs for users. This efficiency not only helps in cost savings but also minimizes the environmental impact, aligning with contemporary sustainability practices.

Another characteristic that sets the DCA-220SSVU apart is its user-friendly operation. The generator comes equipped with a digital control panel that displays critical information, including voltage, frequency, and runtime. This feature enables operators to monitor performance easily and perform quick troubleshooting when necessary.

Safety is paramount with the DCA-220SSVU, which is equipped with various protective features. These include low oil pressure shutdown, high coolant temperature shutdown, and overcurrent protection, ensuring that the generator operates safely and efficiently under varying load conditions.

Additionally, the generator features a large fuel tank that allows for extended run times, making it suitable for long-term projects or emergency situations. The DCA-220SSVU is engineered for enhanced mobility, thanks to its sturdy frame and integrated lifting points, allowing it to be transported easily across different job sites.

In conclusion, the Multiquip DCA-220SSVU is a powerful, efficient, and quiet generator that incorporates advanced technologies, comprehensive safety features, and user-friendly controls. Ideal for contractors and businesses looking for reliable power solutions, this generator exemplifies Multiquip's commitment to quality and innovation in the construction and industrial sectors.