Multiquip DCA-10SPX4 Towing and Transporting Safety, Guidelines section in this manual

Page 14

DCA-10SPX4 — RULES FOR SAFE OPERATION

If your generator is trailer mounted, please read the towing and safety requirements listed below.

Towing and Transporting Safety

To reduce the possibility of an accident while transporting the generator on public roads, always make sure the trailer that supports the generator and the towing vehicle are in good operating condition and both units are mechanically sound.

The following list of safety precautions should be followed when towing your generator:

CAUTION - FOLLOWTOWING REGULATIONS

Check with your local county or state safety towing regulations, in addition to meeting Department of Transportation (DOT) SafetyTowing Regulations, before towing your generator.

ALWAYS shutdown engine before transporting.

Drain fuel from generator fuel tank before towing.

If generator is mounted on a trailer, make sure trailer complies with all local and state safety transportation laws. Follow the listed Towing & Transporting Safety guidelines for basic towing techniques.

Make sure the hitch and coupling of the towing vehicle are rated equal to, or greater than the trailer "gross vehicle weight rating.”

ALWAYS inspect the hitch and coupling for wear. NEVER tow a trailer with defective hitches, couplings, chains etc.

Check the tire air pressure on both towing vehicle and trailer. Trailer tires should be inflated to 50 psi cold. Also check the tire tread wear on both vehicles.

ALWAYS make sure the trailer is equipped with a "Safety Chain".

ALWAYS attach trailer’s safety chains to towing vehicle properly.

ALWAYS make sure the vehicle and trailer directional, backup, brake, and trailer lights are connected and working properly.

DOT Requirements include the following:

Connect and test electric brake operation.

Secure portable power cables in cable tray with tie wraps.

The maximum speed for highway towing is 55 MPH unless posted otherwise. Recommended off-road towing is not to exceed 15 MPH or less depending on type of terrain.

Place chock blocks underneath wheel to prevent rolling, while parked.

Use the trailer’s swivel jack to adjust the trailer height to a level position while parked.

Avoid sudden stops and starts. This can cause skidding, or jack-knifing. Smooth, gradual starts and stops will improve towing.

Avoid sharp turns.

Trailer should be adjusted to a level position at all times when towing.

Raise and lock trailer wheel stand in up position when transporting.

The maximum speed for highway towing is 55 MPH unless posted otherwise. Recommended off-road towing is not to exceed 15 MPH or less depending on type of terrain.

Place support blocks underneath the trailer’s bumper to prevent tipping, while parked.

Avoid sharp turns to prevent rolling.

DO NOT transport generator with fuel in tank.

NOTE

For more saftey tips, see the trailer saftey

 

guidelines section in this manual.

PAGE 14 — DCA-10SPX4— OPERATION AND PARTS MANUAL — REV. #0 (02/17/09)

Image 14
Contents Model DCA-10SPX4 Diesel engine exhaust and some Proposition 65WARNINGDCA-10SPX4- Operation and Parts Manual REV. #0 02/17/09 Table of Contents Parts Ordering Procedures Ordering parts has never been easierDCA-10SPX4 Specifications Dimensions Dimension ft. mmDCA-10SPX4 Safety Message Alert Symbols Hazard SymbolsDCA-10SPX4 Safety Message Alert Symbols Injury People General SafetyDCA-10SPX4 Rules for Safe Operation Carbon monoxide gasDCA-10SPX4 Rules for Safe Operation Battery Safety Death Towing and Transporting Safety Guidelines section in this manualDCA-10SPX4- Operation and Parts Manual REV. #0 02/17/09 DCA-10SPX4 Installation Typical Generator Grounding ApplicationWhen connecting the generator Outdoor InstallationIndoor Installation MountingOutput Terminal Panel GeneratorGenerator Control Panel Open Delta Excitation SystemDCA-10SPX4 Major Components Major ComponentsDCA-10SPX4 Generator Control Panel DCA-10SPX4 Output Terminal Panel Familiarization Output Terminal FamiliarizationL5-30RTwist Lock 120VAC Receptacle Option DCA-10SPX4 Output Terminal Panel Familiarization120VAC Gfci Receptacle Connecting Loads DCA-10SPX4 Output Terminal Panel FamiliarizationGenerator Amperage Single Phase LoadDCA-10SPX4 Load APPLICATION/MAXIMUM Amperage Rated Voltage Maximum AmpsLubrication Oil DCA-10SPX4 SetupCircuit Breakers Fuel CheckRefueling Procedure RefuelingCoolant Antifreeze/Summer Coolant/Water Cleaning the RadiatorAir Cleaner Fan Belt Tension Operation FreezingWeatherWiring BatteryBattery Cable Installation AlternatorDirect exhaust away from nearby personnel Before StartingEngines exhaust contains harmful emissions Close all engine enclosure doors FigureDCA-10SPX4 Generator START-UP Procedure Set the Speed Control Switch to the RUN position FigureNormal Shutdown Procedure Emergency Shutdown ProcedureDCA-10SPX4 Maintenance Check Oil Level Cleaning the Fuel StrainerAir Removal Replacing Oil FilterCheck the wheel and drum for free rotation Brake AdjustmentBrakes Hydraulic Surge BrakesTireWear/Inflation DCA-10SPX4 -TRAILER MaintenanceTires/Wheels/Lug Nuts SuspensionStart all wheel lug nuts by hand DCA-10SPX4 -TRAILER MaintenanceLug Nut Torque Requirements DCA-10SPX4 Generatorwiring Diagram Generator Wiring DiagramDCA-10SPX4 Enginewiring Diagram DCA-10SPX4 -TROUBLESHOOTING Engine Engine TroubleshootingDCA-10SPX4 -TROUBLESHOOTING Engine DCA-10SPX4 -TROUBLESHOOTING Generator DCA-10SPX4 -TROUBLESHOOTING PRE-HEAT Lamp Codes Failure Diagnosis Lamp CodeDCA-10SPX4- Operation and Parts Manual REV. #0 02/17/09 Sample Parts List DCA-10SPX4 Explanation of Code in Remarks ColumnDCA-10SPX4 Suggested Spare Parts To 3 UnitsDCA -10SPX4 Generator Assy DCA 10SPX4 Generator Assy DCA 10SPX4 Control Panel Assy 0601800281 B02240051030601800455 Frequency METER, 45~65 Hz 0601805745 060184007350 DCA-10SPX4- Operation and Parts Manual REV. #0 02/17/09 B0214002903 06018066400601830771 0017108020DCA 10SPX4 Output Receptacle Assy 0601811035 06018151090601812598 0601811033DCA 10SPX4 Engine and Radiator Assy 1641432433 B09242001741638297011 B030420040356 DCA-10SPX4- Operation and Parts Manual REV. #0 02/17/09 0016906015 08020811048702082004 0199900450DCA 10SPX4 Battery Assy 0805002904 0165308026B1345200114 0037808000DCA 10SPX4 Muffler Assy 1526312371 B0331100703B0334000503 0207008000DCA 10SPX4 Fueltank Assy 0810105900 B03640007030810105800 B0364300403DCA 10SPX4 Enclosure Assy B0424001302 B0414002202D3414800104 B049410090466 DCA-10SPX4- Operation and Parts Manual REV. #0 02/17/09 0845047104 084504720439A 0845045004 40A 0845045004DCA 10SPX4 Rubber Seals Assy 0221700900 02292006500229400695 0221700640DCA 10SPX4 Name Plate Assy B9504501204 08406141042635 0800650804Terms and Conditions of Sale Parts FreightpolicyDCA-10SPX4- Operation and Parts Manual REV. #0 02/17/09 Fax 972 Lewisville, TX

DCA-10SPX4 specifications

The Multiquip DCA-10SPX4 is a versatile and robust portable generator designed for a variety of applications, making it an excellent choice for both homeowners and professionals alike. With its compact design and powerful output, the DCA-10SPX4 is ideal for construction sites, outdoor events, and emergency backup power.

One of the standout features of the DCA-10SPX4 is its 10,000 watts of peak power output, ensuring it can handle demanding electrical loads with ease. The generator is powered by a reliable 4-cylinder engine, delivering superior performance while maintaining fuel efficiency. This combination of power and efficiency makes it suitable for both short-term use and extended periods without frequent refueling.

The DCA-10SPX4 is equipped with advanced technologies that enhance its overall reliability. It features an automatic voltage regulator (AVR) which ensures stable voltage output, protecting sensitive equipment from surges and fluctuations. This is particularly important for users who need to power electronics, tools, and other devices that require consistent voltage levels.

Another notable characteristic of the DCA-10SPX4 is its user-friendly control panel, which provides easy access to all essential functions. With multiple outlets, including 120V and 240V options, it accommodates a range of plug types, making it versatile enough for various applications. Additionally, the generator has built-in circuit breakers to prevent overloads and ensures user safety during operation.

Durability is a key aspect of the DCA-10SPX4, as it is engineered with a heavy-duty frame that can withstand rugged conditions commonly encountered on job sites. The generator also features an integrated wheel kit, allowing for easy transportation and maneuverability, which is a significant advantage when moving power equipment from one location to another.

Maintenance is simplified with the DCA-10SPX4, as it includes easy-access service points. Routine checks and oil changes can be performed quickly, ensuring the generator remains operational and prolonging its lifespan.

Overall, the Multiquip DCA-10SPX4 shines in its class due to its powerful performance, advanced technology, and user-friendly features. Whether for emergency backup, construction, or recreational use, it stands out as a reliable and efficient generator that meets the needs of diverse users.