Multiquip DCA-10SPX4 operation manual DCA 10SPX4 Generator Assy

Page 47

DCA - 10SPX4 — GENERATOR ASSY.

GENERATOR ASSY.

 

 

 

NO.

PART NO.

PART NAME

QTY.

REMARKS

1

8321000102

ROTOR ASSY

1

 

1-1

 

FIELD ASSY

1

 

1-2

0601821374

RECTIFIER

1

 

1-3

0601822630

SURGE ABSORBER

1

TNR23G471K

1-4

8001070003

FAN

1

 

1-5

8351611004

COUPLING DISK

2

 

1-6

8351612004

WASHER, COUPLING HUB

1

 

1-7

8351615003

BALANCING PLATE

1

PURCHASE 1-10 AS A SET

1-8

0010310025

HEX HEAD BOLT

4

 

1-9

0042610000

WASHER, LOCK

4

 

1-10

0601000209

BALANCING WEIGHT KIT

1

 

1-11

0071906308

BEARING

1

6308DDU C3

2

0070506903

BEARING

1

6903ZZ

3

0012808035

HEX HEAD BOLT

6

 

5

B0130101003

STATOR ASSY

1

 

5-1

0845041904

GROMMET

1

 

6

8431350003

FIELD ASSY.,EXCITER

1

 

7

0016008045

HEX SOCKET HEAD CAP SCREW

3

 

8

0042508000

WASHER, LOCK

3

 

9

8351315003

END BRACKET

1

 

10

0017108035

HEX HEAD BOLT

6

 

11

8351312004

PACKING

1

 

12

8351331004

COVER, SUCTION

1

 

13

0017106016

HEX HEAD BOLT

3

 

14

0012810025

HEX HEAD BOLT

6

 

16

B0155400204

COVER, FAN

1

 

17

0010106030

HEX HEAD BOLT

1

 

18

0041206000

WASHER, FLAT

1

 

19

0805083204

RUBBER SUSPENSION

2

 

20

0207010000

HEX NUT

2

 

21

0601815000

NUT

1

 

DCA-10SPX4— OPERATION AND PARTS MANUAL — REV. #0 (02/17/09) — PAGE 47

Image 47
Contents Model DCA-10SPX4 Proposition 65WARNING Diesel engine exhaust and someDCA-10SPX4- Operation and Parts Manual REV. #0 02/17/09 Table of Contents Ordering parts has never been easier Parts Ordering ProceduresDCA-10SPX4 Specifications Dimension ft. mm DimensionsHazard Symbols DCA-10SPX4 Safety Message Alert SymbolsDCA-10SPX4 Safety Message Alert Symbols Carbon monoxide gas General SafetyDCA-10SPX4 Rules for Safe Operation Injury PeopleDCA-10SPX4 Rules for Safe Operation Battery Safety Death Guidelines section in this manual Towing and Transporting SafetyDCA-10SPX4- Operation and Parts Manual REV. #0 02/17/09 Typical Generator Grounding Application DCA-10SPX4 InstallationMounting Outdoor InstallationIndoor Installation When connecting the generatorOpen Delta Excitation System GeneratorGenerator Control Panel Output Terminal PanelMajor Components DCA-10SPX4 Major ComponentsDCA-10SPX4 Generator Control Panel Output Terminal Familiarization DCA-10SPX4 Output Terminal Panel FamiliarizationL5-30RTwist Lock 120VAC Receptacle Option DCA-10SPX4 Output Terminal Panel Familiarization120VAC Gfci Receptacle DCA-10SPX4 Output Terminal Panel Familiarization Connecting LoadsRated Voltage Maximum Amps Single Phase LoadDCA-10SPX4 Load APPLICATION/MAXIMUM Amperage Generator AmperageFuel Check DCA-10SPX4 SetupCircuit Breakers Lubrication OilRefueling Refueling ProcedureOperation FreezingWeather Cleaning the RadiatorAir Cleaner Fan Belt Tension Coolant Antifreeze/Summer Coolant/WaterAlternator BatteryBattery Cable Installation WiringClose all engine enclosure doors Figure Before StartingEngines exhaust contains harmful emissions Direct exhaust away from nearby personnelSet the Speed Control Switch to the RUN position Figure DCA-10SPX4 Generator START-UP ProcedureEmergency Shutdown Procedure Normal Shutdown ProcedureDCA-10SPX4 Maintenance Replacing Oil Filter Cleaning the Fuel StrainerAir Removal Check Oil LevelHydraulic Surge Brakes Brake AdjustmentBrakes Check the wheel and drum for free rotationSuspension DCA-10SPX4 -TRAILER MaintenanceTires/Wheels/Lug Nuts TireWear/InflationStart all wheel lug nuts by hand DCA-10SPX4 -TRAILER MaintenanceLug Nut Torque Requirements Generator Wiring Diagram DCA-10SPX4 Generatorwiring DiagramDCA-10SPX4 Enginewiring Diagram Engine Troubleshooting DCA-10SPX4 -TROUBLESHOOTING EngineDCA-10SPX4 -TROUBLESHOOTING Engine DCA-10SPX4 -TROUBLESHOOTING Generator Failure Diagnosis Lamp Code DCA-10SPX4 -TROUBLESHOOTING PRE-HEAT Lamp CodesDCA-10SPX4- Operation and Parts Manual REV. #0 02/17/09 DCA-10SPX4 Explanation of Code in Remarks Column Sample Parts ListTo 3 Units DCA-10SPX4 Suggested Spare PartsDCA -10SPX4 Generator Assy DCA 10SPX4 Generator Assy DCA 10SPX4 Control Panel Assy 0601840073 B02240051030601800455 Frequency METER, 45~65 Hz 0601805745 060180028150 DCA-10SPX4- Operation and Parts Manual REV. #0 02/17/09 0017108020 06018066400601830771 B0214002903DCA 10SPX4 Output Receptacle Assy 0601811033 06018151090601812598 0601811035DCA 10SPX4 Engine and Radiator Assy B0304200403 B09242001741638297011 164143243356 DCA-10SPX4- Operation and Parts Manual REV. #0 02/17/09 0199900450 08020811048702082004 0016906015DCA 10SPX4 Battery Assy 0037808000 0165308026B1345200114 0805002904DCA 10SPX4 Muffler Assy 0207008000 B0331100703B0334000503 1526312371DCA 10SPX4 Fueltank Assy B0364300403 B03640007030810105800 0810105900DCA 10SPX4 Enclosure Assy B0494100904 B0414002202D3414800104 B042400130266 DCA-10SPX4- Operation and Parts Manual REV. #0 02/17/09 40A 0845045004 084504720439A 0845045004 0845047104DCA 10SPX4 Rubber Seals Assy 0221700640 02292006500229400695 0221700900DCA 10SPX4 Name Plate Assy 0800650804 08406141042635 B9504501204Freightpolicy Terms and Conditions of Sale PartsDCA-10SPX4- Operation and Parts Manual REV. #0 02/17/09 Lewisville, TX Fax 972

DCA-10SPX4 specifications

The Multiquip DCA-10SPX4 is a versatile and robust portable generator designed for a variety of applications, making it an excellent choice for both homeowners and professionals alike. With its compact design and powerful output, the DCA-10SPX4 is ideal for construction sites, outdoor events, and emergency backup power.

One of the standout features of the DCA-10SPX4 is its 10,000 watts of peak power output, ensuring it can handle demanding electrical loads with ease. The generator is powered by a reliable 4-cylinder engine, delivering superior performance while maintaining fuel efficiency. This combination of power and efficiency makes it suitable for both short-term use and extended periods without frequent refueling.

The DCA-10SPX4 is equipped with advanced technologies that enhance its overall reliability. It features an automatic voltage regulator (AVR) which ensures stable voltage output, protecting sensitive equipment from surges and fluctuations. This is particularly important for users who need to power electronics, tools, and other devices that require consistent voltage levels.

Another notable characteristic of the DCA-10SPX4 is its user-friendly control panel, which provides easy access to all essential functions. With multiple outlets, including 120V and 240V options, it accommodates a range of plug types, making it versatile enough for various applications. Additionally, the generator has built-in circuit breakers to prevent overloads and ensures user safety during operation.

Durability is a key aspect of the DCA-10SPX4, as it is engineered with a heavy-duty frame that can withstand rugged conditions commonly encountered on job sites. The generator also features an integrated wheel kit, allowing for easy transportation and maneuverability, which is a significant advantage when moving power equipment from one location to another.

Maintenance is simplified with the DCA-10SPX4, as it includes easy-access service points. Routine checks and oil changes can be performed quickly, ensuring the generator remains operational and prolonging its lifespan.

Overall, the Multiquip DCA-10SPX4 shines in its class due to its powerful performance, advanced technology, and user-friendly features. Whether for emergency backup, construction, or recreational use, it stands out as a reliable and efficient generator that meets the needs of diverse users.