Multiquip DCA-10SPX4 Coolant Antifreeze/Summer Coolant/Water, Cleaning the Radiator

Page 27

Coolant (Antifreeze/Summer Coolant/Water)

KUBOTA recommends antifreeze/summer coolant for use in their engines, which can be purchased in concentrate (and mixed with 50% demineralized water) or pre-diluted. See the KUBOTA Engine Owner's Manual for further details.

DCA-10SPX4 — SETUP

Cleaning the Radiator

The engine may overheat if the radiator fins become overloaded with dust or debris. Periodically clean the radiator fins with compressed air. Cleaning inside the machine is dangerous, so clean only with the engine turned off and the negative battery terminal disconnected.

WARNING - BURN HAZARDS

If adding coolant/antifreeze mix to the radiator, DO NOT remove the radiator cap until the unit has completely cooled.The possibility of hot! coolant exists which can cause severe burns.

Day-to-day addition of coolant is done from the recovery tank. When adding coolant to the radiator, DO NOT remove the radiator cap until the unit has completely cooled. See Table 9 for engine, radiator, and recovery tank coolant capacities. Make sure the coolant level in the recovery tank is always between the "H" and the "L" markings.

Table 9. Coolant Capacity

Engine and Radiator

1.85 Gal. (7.0 liters)

 

 

Reserve Tank

.264 Gal (1.0 liters)

 

 

Operation FreezingWeather

When operating in freezing weather, be certain the proper amount of antifreeze (Table 10) has been added.

Table 10. Anti-Freeze

Operating Temperatures

Vol %

Freezing Point

 

 

Anti-Freeze

 

 

°C

°F

 

 

 

 

50

-37

-34

 

 

 

Air Cleaner

Periodic cleaning/replacement is necessary. Inspect it in accordance with the KUBOTA Engine Owner's Manual.

Fan Belt Tension

A slack fan belt may contribute to overheating, or to insufficient charging of the battery. Inspect the fan belt for damage and wear and adjust it in accordance with the

KUBOTA Engine Owner's Manual.

The fan belt tension is proper if the fan belt bends 10 to 15

mm(Figure 18) when depressed with the thumb as shown below.

Figure 18. Fan Belt Tension

CAUTION - ROTATING PARTS

NEVER place hands near the belts or fan while the generator set is running.

NOTE

When the antifreeze is mixed with

water, the antifreeze mixing ratio

 

 

must be less than 50%.

DCA-10SPX4— OPERATION AND PARTS MANUAL — REV. #0 (02/17/09) — PAGE 27

Image 27
Contents Model DCA-10SPX4 Proposition 65WARNING Diesel engine exhaust and someDCA-10SPX4- Operation and Parts Manual REV. #0 02/17/09 Table of Contents Ordering parts has never been easier Parts Ordering ProceduresDCA-10SPX4 Specifications Dimension ft. mm DimensionsHazard Symbols DCA-10SPX4 Safety Message Alert SymbolsDCA-10SPX4 Safety Message Alert Symbols Carbon monoxide gas General SafetyDCA-10SPX4 Rules for Safe Operation Injury PeopleDCA-10SPX4 Rules for Safe Operation Battery Safety Death Guidelines section in this manual Towing and Transporting SafetyDCA-10SPX4- Operation and Parts Manual REV. #0 02/17/09 Typical Generator Grounding Application DCA-10SPX4 InstallationMounting Outdoor InstallationIndoor Installation When connecting the generatorOpen Delta Excitation System GeneratorGenerator Control Panel Output Terminal PanelMajor Components DCA-10SPX4 Major ComponentsDCA-10SPX4 Generator Control Panel Output Terminal Familiarization DCA-10SPX4 Output Terminal Panel FamiliarizationDCA-10SPX4 Output Terminal Panel Familiarization 120VAC Gfci ReceptacleL5-30RTwist Lock 120VAC Receptacle Option DCA-10SPX4 Output Terminal Panel Familiarization Connecting LoadsRated Voltage Maximum Amps Single Phase LoadDCA-10SPX4 Load APPLICATION/MAXIMUM Amperage Generator AmperageFuel Check DCA-10SPX4 SetupCircuit Breakers Lubrication OilRefueling Refueling ProcedureOperation FreezingWeather Cleaning the RadiatorAir Cleaner Fan Belt Tension Coolant Antifreeze/Summer Coolant/WaterAlternator BatteryBattery Cable Installation WiringClose all engine enclosure doors Figure Before StartingEngines exhaust contains harmful emissions Direct exhaust away from nearby personnelSet the Speed Control Switch to the RUN position Figure DCA-10SPX4 Generator START-UP ProcedureEmergency Shutdown Procedure Normal Shutdown ProcedureDCA-10SPX4 Maintenance Replacing Oil Filter Cleaning the Fuel StrainerAir Removal Check Oil LevelHydraulic Surge Brakes Brake AdjustmentBrakes Check the wheel and drum for free rotationSuspension DCA-10SPX4 -TRAILER MaintenanceTires/Wheels/Lug Nuts TireWear/InflationDCA-10SPX4 -TRAILER Maintenance Lug Nut Torque RequirementsStart all wheel lug nuts by hand Generator Wiring Diagram DCA-10SPX4 Generatorwiring DiagramDCA-10SPX4 Enginewiring Diagram Engine Troubleshooting DCA-10SPX4 -TROUBLESHOOTING EngineDCA-10SPX4 -TROUBLESHOOTING Engine DCA-10SPX4 -TROUBLESHOOTING Generator Failure Diagnosis Lamp Code DCA-10SPX4 -TROUBLESHOOTING PRE-HEAT Lamp CodesDCA-10SPX4- Operation and Parts Manual REV. #0 02/17/09 DCA-10SPX4 Explanation of Code in Remarks Column Sample Parts ListTo 3 Units DCA-10SPX4 Suggested Spare PartsDCA -10SPX4 Generator Assy DCA 10SPX4 Generator Assy DCA 10SPX4 Control Panel Assy 0601840073 B02240051030601800455 Frequency METER, 45~65 Hz 0601805745 060180028150 DCA-10SPX4- Operation and Parts Manual REV. #0 02/17/09 0017108020 06018066400601830771 B0214002903DCA 10SPX4 Output Receptacle Assy 0601811033 06018151090601812598 0601811035DCA 10SPX4 Engine and Radiator Assy B0304200403 B09242001741638297011 164143243356 DCA-10SPX4- Operation and Parts Manual REV. #0 02/17/09 0199900450 08020811048702082004 0016906015DCA 10SPX4 Battery Assy 0037808000 0165308026B1345200114 0805002904DCA 10SPX4 Muffler Assy 0207008000 B0331100703B0334000503 1526312371DCA 10SPX4 Fueltank Assy B0364300403 B03640007030810105800 0810105900DCA 10SPX4 Enclosure Assy B0494100904 B0414002202D3414800104 B042400130266 DCA-10SPX4- Operation and Parts Manual REV. #0 02/17/09 40A 0845045004 084504720439A 0845045004 0845047104DCA 10SPX4 Rubber Seals Assy 0221700640 02292006500229400695 0221700900DCA 10SPX4 Name Plate Assy 0800650804 08406141042635 B9504501204Freightpolicy Terms and Conditions of Sale PartsDCA-10SPX4- Operation and Parts Manual REV. #0 02/17/09 Lewisville, TX Fax 972

DCA-10SPX4 specifications

The Multiquip DCA-10SPX4 is a versatile and robust portable generator designed for a variety of applications, making it an excellent choice for both homeowners and professionals alike. With its compact design and powerful output, the DCA-10SPX4 is ideal for construction sites, outdoor events, and emergency backup power.

One of the standout features of the DCA-10SPX4 is its 10,000 watts of peak power output, ensuring it can handle demanding electrical loads with ease. The generator is powered by a reliable 4-cylinder engine, delivering superior performance while maintaining fuel efficiency. This combination of power and efficiency makes it suitable for both short-term use and extended periods without frequent refueling.

The DCA-10SPX4 is equipped with advanced technologies that enhance its overall reliability. It features an automatic voltage regulator (AVR) which ensures stable voltage output, protecting sensitive equipment from surges and fluctuations. This is particularly important for users who need to power electronics, tools, and other devices that require consistent voltage levels.

Another notable characteristic of the DCA-10SPX4 is its user-friendly control panel, which provides easy access to all essential functions. With multiple outlets, including 120V and 240V options, it accommodates a range of plug types, making it versatile enough for various applications. Additionally, the generator has built-in circuit breakers to prevent overloads and ensures user safety during operation.

Durability is a key aspect of the DCA-10SPX4, as it is engineered with a heavy-duty frame that can withstand rugged conditions commonly encountered on job sites. The generator also features an integrated wheel kit, allowing for easy transportation and maneuverability, which is a significant advantage when moving power equipment from one location to another.

Maintenance is simplified with the DCA-10SPX4, as it includes easy-access service points. Routine checks and oil changes can be performed quickly, ensuring the generator remains operational and prolonging its lifespan.

Overall, the Multiquip DCA-10SPX4 shines in its class due to its powerful performance, advanced technology, and user-friendly features. Whether for emergency backup, construction, or recreational use, it stands out as a reliable and efficient generator that meets the needs of diverse users.