Multiquip DCA-10SPX4 operation manual Battery Cable Installation, Alternator, Wiring

Page 28

Battery

This unit is of negative ground DO NOT connect in reverse. Always maintain battery fluid level between the specified marks. Battery life will be shortened, if the fluid level are not properly maintained. Add only distilled water when replenishment is necessary.

DO NOT over fill. Check to see whether the battery cables are loose. Poor contact may result in poor starting or malfunctions. Always keep the terminals firmly tightened. Coating the terminals with an approved battery terminal treatment compound. Replace battery with only recommended type battery.

The battery is sufficiently charged if the specific gravity of the battery fluid is 1.28 (at 68° F). If the specific gravity should fall to 1.245 or lower, it indicates that the battery is dead and needs to be recharged or replaced.

Before charging the battery with an external electric source, be sure to disconnect the battery cables.

Battery Cable Installation

ALWAYS be sure the battery cables (Figure 19) are properly connected to the battery terminals as shown below.The Red Cable is connected to the positive terminal of the battery, and the Black Cable is connected to the negative terminal of the battery.

CAUTION - BATTERY SERVICING SAFETY

ALWAYS disconnect the negative terminal FIRST and reconnect negative terminal LAST.

DCA-10SPX4 — SETUP

When connecting battery do the following:

1.NEVER connect the battery cables to the battery terminals when the ignition switch is in the ON position

2.Place a small amount of battery terminal treatment compound around both battery terminals.This will ensure a good connection and will help prevent corrosion around the battery terminals.

If the battery cable is connected

NOTE incorrectly, electrical damage to the generator will occur. Pay close attention to the polarity of the battery when connecting the battery.

CAUTION - BATTERY SERVICING SAFETY

Inadequate battery connections may cause poor starting of the generator, and create other malfunctions.

Alternator

The polarity of the alternator is negative grounding type. When an inverted circuit connection takes place, the circuit will be in short circuit instantaneously resulting the alternator failure.

DO NOT put water directly on the alternator. Entry of water into the alternator can cause corrision and damage the alternator.

Wiring

Inspect the entire generator for bad or worn electrical wiring or connections. If any wiring or connections are exposed (insulation missing) replace wiring immediately.

Piping and Hose Connection

Inspect all piping, oil hose, and fuel hose connections for wear and tightness.Tighten all hose clamps and check hoses for leaks.

If any hose (fuel or oil) lines are defective replace them immediately.

Figure 19. Battery Connections

PAGE 28 — DCA-10SPX4— OPERATION AND PARTS MANUAL — REV. #0 (02/17/09)

Image 28
Contents Model DCA-10SPX4 Diesel engine exhaust and some Proposition 65WARNINGDCA-10SPX4- Operation and Parts Manual REV. #0 02/17/09 Table of Contents Parts Ordering Procedures Ordering parts has never been easierDCA-10SPX4 Specifications Dimensions Dimension ft. mmDCA-10SPX4 Safety Message Alert Symbols Hazard SymbolsDCA-10SPX4 Safety Message Alert Symbols General Safety DCA-10SPX4 Rules for Safe OperationInjury People Carbon monoxide gasDCA-10SPX4 Rules for Safe Operation Battery Safety Death Towing and Transporting Safety Guidelines section in this manualDCA-10SPX4- Operation and Parts Manual REV. #0 02/17/09 DCA-10SPX4 Installation Typical Generator Grounding ApplicationOutdoor Installation Indoor InstallationWhen connecting the generator MountingGenerator Generator Control PanelOutput Terminal Panel Open Delta Excitation SystemDCA-10SPX4 Major Components Major ComponentsDCA-10SPX4 Generator Control Panel DCA-10SPX4 Output Terminal Panel Familiarization Output Terminal Familiarization120VAC Gfci Receptacle DCA-10SPX4 Output Terminal Panel FamiliarizationL5-30RTwist Lock 120VAC Receptacle Option Connecting Loads DCA-10SPX4 Output Terminal Panel FamiliarizationSingle Phase Load DCA-10SPX4 Load APPLICATION/MAXIMUM AmperageGenerator Amperage Rated Voltage Maximum AmpsDCA-10SPX4 Setup Circuit BreakersLubrication Oil Fuel CheckRefueling Procedure RefuelingCleaning the Radiator Air Cleaner Fan Belt TensionCoolant Antifreeze/Summer Coolant/Water Operation FreezingWeatherBattery Battery Cable InstallationWiring AlternatorBefore Starting Engines exhaust contains harmful emissionsDirect exhaust away from nearby personnel Close all engine enclosure doors FigureDCA-10SPX4 Generator START-UP Procedure Set the Speed Control Switch to the RUN position FigureNormal Shutdown Procedure Emergency Shutdown ProcedureDCA-10SPX4 Maintenance Cleaning the Fuel Strainer Air RemovalCheck Oil Level Replacing Oil FilterBrake Adjustment BrakesCheck the wheel and drum for free rotation Hydraulic Surge BrakesDCA-10SPX4 -TRAILER Maintenance Tires/Wheels/Lug NutsTireWear/Inflation SuspensionLug Nut Torque Requirements DCA-10SPX4 -TRAILER MaintenanceStart all wheel lug nuts by hand DCA-10SPX4 Generatorwiring Diagram Generator Wiring DiagramDCA-10SPX4 Enginewiring Diagram DCA-10SPX4 -TROUBLESHOOTING Engine Engine TroubleshootingDCA-10SPX4 -TROUBLESHOOTING Engine DCA-10SPX4 -TROUBLESHOOTING Generator DCA-10SPX4 -TROUBLESHOOTING PRE-HEAT Lamp Codes Failure Diagnosis Lamp CodeDCA-10SPX4- Operation and Parts Manual REV. #0 02/17/09 Sample Parts List DCA-10SPX4 Explanation of Code in Remarks ColumnDCA-10SPX4 Suggested Spare Parts To 3 UnitsDCA -10SPX4 Generator Assy DCA 10SPX4 Generator Assy DCA 10SPX4 Control Panel Assy B0224005103 0601800455 Frequency METER, 45~65 Hz 06018057450601800281 060184007350 DCA-10SPX4- Operation and Parts Manual REV. #0 02/17/09 0601806640 0601830771B0214002903 0017108020DCA 10SPX4 Output Receptacle Assy 0601815109 06018125980601811035 0601811033DCA 10SPX4 Engine and Radiator Assy B0924200174 16382970111641432433 B030420040356 DCA-10SPX4- Operation and Parts Manual REV. #0 02/17/09 0802081104 87020820040016906015 0199900450DCA 10SPX4 Battery Assy 0165308026 B13452001140805002904 0037808000DCA 10SPX4 Muffler Assy B0331100703 B03340005031526312371 0207008000DCA 10SPX4 Fueltank Assy B0364000703 08101058000810105900 B0364300403DCA 10SPX4 Enclosure Assy B0414002202 D3414800104B0424001302 B049410090466 DCA-10SPX4- Operation and Parts Manual REV. #0 02/17/09 0845047204 39A 08450450040845047104 40A 0845045004DCA 10SPX4 Rubber Seals Assy 0229200650 02294006950221700900 0221700640DCA 10SPX4 Name Plate Assy 0840614104 2635B9504501204 0800650804Terms and Conditions of Sale Parts FreightpolicyDCA-10SPX4- Operation and Parts Manual REV. #0 02/17/09 Fax 972 Lewisville, TX

DCA-10SPX4 specifications

The Multiquip DCA-10SPX4 is a versatile and robust portable generator designed for a variety of applications, making it an excellent choice for both homeowners and professionals alike. With its compact design and powerful output, the DCA-10SPX4 is ideal for construction sites, outdoor events, and emergency backup power.

One of the standout features of the DCA-10SPX4 is its 10,000 watts of peak power output, ensuring it can handle demanding electrical loads with ease. The generator is powered by a reliable 4-cylinder engine, delivering superior performance while maintaining fuel efficiency. This combination of power and efficiency makes it suitable for both short-term use and extended periods without frequent refueling.

The DCA-10SPX4 is equipped with advanced technologies that enhance its overall reliability. It features an automatic voltage regulator (AVR) which ensures stable voltage output, protecting sensitive equipment from surges and fluctuations. This is particularly important for users who need to power electronics, tools, and other devices that require consistent voltage levels.

Another notable characteristic of the DCA-10SPX4 is its user-friendly control panel, which provides easy access to all essential functions. With multiple outlets, including 120V and 240V options, it accommodates a range of plug types, making it versatile enough for various applications. Additionally, the generator has built-in circuit breakers to prevent overloads and ensures user safety during operation.

Durability is a key aspect of the DCA-10SPX4, as it is engineered with a heavy-duty frame that can withstand rugged conditions commonly encountered on job sites. The generator also features an integrated wheel kit, allowing for easy transportation and maneuverability, which is a significant advantage when moving power equipment from one location to another.

Maintenance is simplified with the DCA-10SPX4, as it includes easy-access service points. Routine checks and oil changes can be performed quickly, ensuring the generator remains operational and prolonging its lifespan.

Overall, the Multiquip DCA-10SPX4 shines in its class due to its powerful performance, advanced technology, and user-friendly features. Whether for emergency backup, construction, or recreational use, it stands out as a reliable and efficient generator that meets the needs of diverse users.