OPERATING INSTRUCTIONS

MILLI-VOLT CONTROL LIGHTING INSTRUCTIONS

1.STOP! Read the safety information label.

2.Make sure the manual shutoff valve is fully open.

3.This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot. If piezo ignitor does not light the pilot, refer to instructions for “MATCH LIGHTING INSTRUCTIONS”, page 27.

4.Turn gas control knob clockwise to the OFF position, set the thermostat to the lowest setting and turn ON/OFF switch to OFF position.

5.Wait (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information label. If you don't smell gas, go to next step.

6. From OFF position, turn the gas control knob counterclockwise to IGN position. Push in

control knob for 5 seconds. NOTE: If you are running the heater for the first time, it will be necessary to press in the control knob for 30 seconds to allow air to bleed out of the gas piping.

7.With the control knob pushed in, push in and release the piezo ignitor button to light the pilot.

8.Continue pushing the control knob in for a further 10 seconds to prevent the flame detector from shutting off the gas while the probe is warming up. Release the control knob.

9.Turn gas control knob counterclockwise to the ON position.

10.After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF switch to ON position or adjust thermostat to desired setting.

11.If the gas logs will not operate, follow the instructions “TO TURN OFF GAS TO APPLIANCE” below and call your service technician or gas supplier.

Hi/Lo Control

LO

Ignitor Control

HI

PILOT

 

 

 

ON

OF

 

 

F

Piezo

On/Off Switch

Figure 22 - Pilot

Figure 23 - Control Cover Plate

TO TURN OFF GAS TO HEATER

1.Turn control knob clockwise to OFF position to completely shut off the heater.

2.If applicable: Turn ON/OFF switch to OFF position and/or set thermostat (if present) to lowest setting.

3.If applicable: Turn off all electric power to the heater.

26

43D0122

Image 26
Contents What to do if YOU Smell GAS Model DST30Read and Save These Instructions Contents Owner Important Safety InformationInstaller For Massachusetts Residents only Make Sure YOU have Received ALL Parts What YOU will Need for InstallationGetting Started PROPANE/LPG Product Features and SpecificationsNatural GAS Adequate Combustion and Ventilation AIR General Installation InformationCodes BTU/Hr = 15 1/ 2 + 12 x 12 x 1000 = 52800 BTU/Hr Fireplace and Hearth Dimensions Placement in a Fireplace with a Restrictive Barrier Height of Restriction Minimum Depth of Fireplace/FireboxClearances and Height Requirements Sidewall and Ceiling ClearancesClearances and Height Requirements Measuring Heat Resistant Material for Mantel Clearances and Height Requirments Maximum of 10 at a minimum of 28 above the fireboxFloor Clearance Minimum Clearance above Combustible FlooringBefore Installing the Appliance Installing Vented ApplicationsBefore Fully Installing the Unit Damper Stop InstallationPlacing and Securing Appliance Installing Vented ApplicationsAssembly Procedure Connecting the GAS Gas ConnectionChecking GAS Pressure MILLI-VOLT Control FigureOperate Electrical Wiring MILLI-VOLTConnecting Optional Wall Switch or Thermostat Complete Millivolt System Check Connecting Remote ReceiverChecking System Operation LOG Placement Placing the Decorative RockMILLI-VOLT Control Flame AppearanceChecking the Pilot Flame Checking the Burner Flame Operating InstructionsWhat to do if YOU Smell GAS For Your Safety Read Before LightingOperating Instructions MILLI-VOLT Control Lighting Instructions To Turn OFF GAS to HeaterMatch Lighting Instructions Operating Instructions and Cleaning and ServicingCleaning and Servicing Troubleshooting Observed Problem Possible Cause RemedyBurner does not light after ODS Illustrated Parts Breakdown Replacement Parts List Replacement Parts are Available Through Your RetailerBasic Warranty Lifetime WarrantyFive Year Warranty