Monessen Hearth dst30 operating instructions Burner does not light after ODS

Page 29

TROUBLESHOOTING

WARNING

If the gas quality is bad, your pilot may not stay lit, the burners may produce soot and the heater may backfire when lit. If the gas quality or pressure is low, contact your local gas supplier immediately.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

 

ODS/pilot lights, but flame goes out when control knob is released.

1.Control knob not fully pressed in.

2.Control knob not pressed in long enough.

3.Manual shutoff valve not fully open.

4.Thermocouple connection loose at control valve.

5.Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by either low gas pressure, or a dirty or partially clogged ODS/pilot.

6.Thermocouple damaged.

7.Control valve damaged.

1.Press in control knob fully.

2.After ODS/pilot lights, keep control knob pressed in for 30 seconds.

3.Fully open manual shutoff valve.

4.Hand tighten thermocouple connection until snug, then tighten 1/4 turn more.

5.Contact local gas company.

6.Replace thermocouple.

7.Replace control valve.

Burner does not light after ODS/

1.

Burner orifice is clogged.

1.

Clean orifice.

pilot is lit.

2.

Burner orifice diameter is too small.

2.

Replace burner orifice.

 

3.

Inlet gas pressure is too low.

3.

Contact qualified service person.

 

 

 

 

 

Burner backfires during com-

1.

Manifold pressure is too low.

1.

Contact local gas company.

bustion.

2.

Burner orifice is clogged.

2.

Clean burner or replace burner orifice.

 

 

 

 

 

Slight smoke or odor during

1.

Burner orifice is clogged or damaged.

1.

Clean burner or replace burner orifice.

initial operation.

2.

Burner is damaged.

2.

Replace burner.

 

3.

Gas regulator defective.

3.

Replace gas regulator.

 

 

 

 

 

Logs appear to smoke after ini-

1.

Vapors from paint or curing process of logs.

1.

Problem will stop after a few hours

tial operation.

 

 

 

of operation. Run the heater with the

 

 

 

 

damper open if you have one, or open a

 

 

 

 

window for the first few hours.

 

 

 

2.

Log heater is intended to be smokeless.

 

 

 

 

Turn OFF heater and call qualified

 

 

 

 

service person.

Heater produces a whistling noise when burner is lit.

1.Turning control knob to HIGH position when burner is cold.

2.Air in gas line.

3.Dirty or partially clogged burner orifices.

1.Turn control knob to LOW position and let warm up for a minute.

2.Operate burner until air is removed from line. Have gas line checked by local gas company.

3.Clean burner or replace burner orifice.

No gas to pilot.

1. LP-regulator shut down due to inlet pressure

 

too high.

1.Verify LP tank regulator is installed and set at 11" to 13" w.c.

2.Replace regulator on heater.

43D0122

29

Image 29
Contents What to do if YOU Smell GAS Model DST30Read and Save These Instructions Contents Owner Important Safety InformationInstaller For Massachusetts Residents only Make Sure YOU have Received ALL Parts What YOU will Need for InstallationGetting Started PROPANE/LPG Product Features and SpecificationsNatural GAS Adequate Combustion and Ventilation AIR General Installation InformationCodes BTU/Hr = 15 1/ 2 + 12 x 12 x 1000 = 52800 BTU/Hr Fireplace and Hearth Dimensions Height of Restriction Minimum Depth of Fireplace/Firebox Placement in a Fireplace with a Restrictive BarrierSidewall and Ceiling Clearances Clearances and Height RequirementsClearances and Height Requirements Measuring Heat Resistant Material for Mantel Maximum of 10 at a minimum of 28 above the firebox Clearances and Height RequirmentsMinimum Clearance above Combustible Flooring Floor ClearanceBefore Fully Installing the Unit Installing Vented ApplicationsBefore Installing the Appliance Damper Stop InstallationPlacing and Securing Appliance Installing Vented ApplicationsAssembly Procedure Gas Connection Connecting the GASMILLI-VOLT Control Figure Checking GAS PressureOperate Electrical Wiring MILLI-VOLTConnecting Optional Wall Switch or Thermostat Complete Millivolt System Check Connecting Remote ReceiverChecking System Operation Placing the Decorative Rock LOG PlacementMILLI-VOLT Control Flame AppearanceChecking the Pilot Flame Operating Instructions Checking the Burner FlameWhat to do if YOU Smell GAS For Your Safety Read Before LightingOperating Instructions To Turn OFF GAS to Heater MILLI-VOLT Control Lighting InstructionsMatch Lighting Instructions Operating Instructions and Cleaning and ServicingCleaning and Servicing Observed Problem Possible Cause Remedy TroubleshootingBurner does not light after ODS Illustrated Parts Breakdown Replacement Parts are Available Through Your Retailer Replacement Parts ListBasic Warranty Lifetime WarrantyFive Year Warranty