Monessen Hearth dst30 operating instructions General Installation Information, Codes

Page 7

GENERAL INSTALLATION INFORMATION

CODES

Adhere to all local codes or, in their absence, the latest edition of THE NATIONAL FUEL GAS CODE ANSI Z223.1 or NFPA54 which can be obtained from…

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

or

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

ADEQUATE COMBUSTION AND VENTILATION AIR

This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.

The National Fuel Gas Code, (ANSI Z223.1/NFPA54), defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 BTU per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space, and an unconfined space is defined as a space whose volume is not less than 50 cubic feet per 1,000 BTU per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed, through openings not furnished with doors, are considered a part of the unconfined space.

UNUSUALLY TIGHT CONSTRUCTION IS DEFINED AS CONSTRUCTION WHERE…

a)walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of 1 perm (6 x 1011 kg/pa-sec-m2) or less with openings gasketed or sealed;

b)weather striping has been added on openable windows and doors; and

c)caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.

43D0122

7

Image 7
Contents Read and Save These Instructions Model DST30What to do if YOU Smell GAS Contents Installer Important Safety InformationOwner For Massachusetts Residents only Getting Started What YOU will Need for InstallationMake Sure YOU have Received ALL Parts Natural GAS Product Features and SpecificationsPROPANE/LPG Codes General Installation InformationAdequate Combustion and Ventilation AIR BTU/Hr = 15 1/ 2 + 12 x 12 x 1000 = 52800 BTU/Hr Fireplace and Hearth Dimensions Height of Restriction Minimum Depth of Fireplace/Firebox Placement in a Fireplace with a Restrictive BarrierSidewall and Ceiling Clearances Clearances and Height RequirementsClearances and Height Requirements Measuring Heat Resistant Material for Mantel Maximum of 10 at a minimum of 28 above the firebox Clearances and Height RequirmentsMinimum Clearance above Combustible Flooring Floor ClearanceDamper Stop Installation Installing Vented ApplicationsBefore Fully Installing the Unit Before Installing the ApplianceAssembly Procedure Installing Vented ApplicationsPlacing and Securing Appliance Gas Connection Connecting the GASMILLI-VOLT Control Figure Checking GAS PressureConnecting Optional Wall Switch or Thermostat Electrical Wiring MILLI-VOLTOperate Checking System Operation Connecting Remote ReceiverComplete Millivolt System Check Placing the Decorative Rock LOG PlacementChecking the Pilot Flame Flame AppearanceMILLI-VOLT Control Operating Instructions Checking the Burner FlameOperating Instructions For Your Safety Read Before LightingWhat to do if YOU Smell GAS To Turn OFF GAS to Heater MILLI-VOLT Control Lighting InstructionsCleaning and Servicing Operating Instructions and Cleaning and ServicingMatch Lighting Instructions Observed Problem Possible Cause Remedy TroubleshootingBurner does not light after ODS Illustrated Parts Breakdown Replacement Parts are Available Through Your Retailer Replacement Parts ListFive Year Warranty Lifetime WarrantyBasic Warranty