8-3. Servicing Air Cleaner

 

 

 

 

 

Y Stop engine.

 

 

 

 

 

Y Do not run engine without air

1

2

3

4

 

cleaner or with dirty element. En-

 

gine damage caused by using a

 

 

 

 

 

 

 

 

 

 

damaged element is not covered

 

 

 

 

 

by the warranty.

 

 

 

 

 

. The air cleaner primary element can

 

 

 

 

 

be cleaned but the dirt holding capac-

 

 

 

 

 

ity of the filter is reduced with each

 

 

 

 

 

cleaning. The chance of dirt reaching

 

 

 

 

 

the clean side of the filter while clean-

 

Optional

 

 

 

ing and the possibility of filter damage

 

 

 

 

makes cleaning a risk. Consider the

 

 

 

 

5

risk of unwarrantable equipment

 

 

 

 

damage when determining whether

 

 

 

 

 

 

 

 

 

 

to clean or replace the primary ele-

 

 

 

 

 

ment.

 

 

 

 

 

If you decide to clean the primary ele-

 

 

 

 

 

ment, we strongly recommend instal-

 

 

 

 

 

ling an optional safety element to pro-

 

 

 

 

 

vide additional engine protection.

 

 

 

 

 

Never clean a safety element. Re-

 

 

 

 

 

place the safety element after servic-

 

 

 

 

 

ing the primary element three times.

Keep nozzle 2 in (51 mm) from element.

Clean or replace primary element if dirty (see note above before cleaning). Re- place primary element if damaged. Re- place primary element yearly or after six cleanings.

1 Housing

2 Safety Element (Optional)

3 Primary Element

4 Dust Cap

5 Dust Ejector

To clean air filter:

Wipe off cap and housing. Remove cap and dump out dust. Remove element(s). Wipe dust from inside cap and housing

BlowInspectwith damp cloth. Reinstall safety element (if present). Reinstall cap.

Y Do not clean housing with air hose.

Clean primary element with compressed air only.

Air pressure must not exceed 100 psi (690 kPa). Use 1/8 in (3 mm) nozzle and keep nozzle at least 2 in (51 mm) from inside of element. Replace primary ele- ment if it has holes or damaged gaskets.

Reinstall primary element and cap (dust ejector down).

aircleaner1 2/01− ST-153 929-B / ST-153 585 / Ref. S-0698-B / Ref. 217 357-A

OM-4433 Page 32

Image 36
Contents OM-4433218 314K ProcessesDescription File Engine DriveFrom Miller to You Table of Contents Warranty Symbol Usage Arc Welding HazardsEngine Hazards Compressed Air Hazards Principal Safety Standards California Proposition 65 WarningsEMF Information Radiation can cause interferenceSignification des symboles − Consignes DE Sécurité − Lire Avant UtilisationUN Choc Électrique peut tuer LES Fumées ET LES GAZ peuvent être dangereuxLE Soudage peut provoquer un in- cendie ou une explosion DES Particules Volantes peuvent blesser les yeuxDES Pièces Chaudes peuvent provoquer des brûlures graves LE Bruit peut affecter l’ouïeLA Chaleur DU Moteur peut pro- voquer un incendie ’AIR Comprimé peut provoquer des blessures’EMPLOI Excessif peut LE Surchauffement peut endom- mager le moteur électriqueLE Soudage À L’ARC risque de provoquer des interférences Pour les moteurs à essencePour les moteurs diesel Boulevard, Rexdale, Ontario, Canada M9W 1R3 téléphone− Definitions − 50 h StdStd Manufacturer’s Rating Label Symbols And Definitions − Specifications Weld, Power, And Engine SpecificationsDimensions, Weights, And Operating Angles Stick Mode MIG ModeTIG Mode Volt-Ampere CurvesCurve shows typical fuel use under weld or power loads Exceeding duty cycle can damage unit and void warrantyFuel Consumption Duty Cycle And OverheatingAC Generator Power Curve 150 125 100− Installation Installing Welding GeneratorSee -2for lifting eye rating See -2for mounting information GroundingMounting Welding Generator Installing Exhaust Pipe Tools Needed 1/2Stop engine and let cool Point exhaust pipe in desired diActivating The Dry Charge Battery If Applicable Connecting The BatteryDo not overfill battery cells Close door after connecting batteryCoolant Recovery Tank Engine Prestart ChecksFuel Do not use gasoline. Gasoline will damage engine OilConnecting To Weld Output Terminals Stick and TIG WeldingMIG and Fcaw Welding Stop engineSelecting Weld Cable Sizes 150 ft 200 ft 250 ft350 ft 400 ft 45 m 60 m 70 m 90 m 105 m 120 m Stop engine beforeConnecting To Remote 14 Receptacle RC14 Socket Information− Operating Welding Generator Front Panel Controls See SectionDescription Of Front Panel Controls See Section Process/Contactor Switch Process/Contactor Switch SettingsLift-ArcStart Procedure Lift-Arc Start Method TouchDo not Strike Like a Match Lift-Arc t TIGRemote Voltage/Amperage Control Generator Power Receptacles − Operating Auxiliary EquipmentAt least once a month, run engine at − Maintenance & Troubleshooting Routine MaintenanceMaintenance Label Servicing Air Cleaner By the warrantyTo clean air filter Do not clean housing with air hoseInspecting And Cleaning Optional Spark Arrestor Muffler Stop engine and let cool. Reinstall cleanout plugServicing Engine Cooling System Adjusting Engine Speed On Standard Models MaximumDo not set engine speed higher Stop engine. Close doorEngine Speed Adjustment Weld/Power Speed Adjust- mentEngine Speed No Load Rpm max 62.6 Hz 1250 rpm 41.6 HzServicing Fuel And Lubrication Systems To change oil and filterTo replace primary canister fuel filter To drain water from fuel systemOverload Protection Checking Generator Brushes Replace Damaged BrushesVoltmeter/Ammeter Help Displays Help 20 DisplayHelp 25 Display Troubleshooting WeldingGenerator Power EngineCheck for obstructed throttle solenoid Material Thickness Reference Chart − Electrical Diagrams Circuit Diagram For Welding Generator219 228−D − RUN-IN Procedure WetstackingWelding Generator Run-In Procedure Using Load Bank Procedure at less thanStop engine Do not touch hot exhaust From flammables Do not PerformRun-In Procedure Using Resistance Grid Bank/gridFrom flammables Do not perform run-in− Generator Power Guidelines Has this symbolSelecting Equipment Grounding Generator To Truck Or Trailer FrameGrounding When Supplying Building Systems How Much Power Does Equipment Require?Earth ground if supplying Use ground device as stated Electrical codesApproximate Power Requirements For Industrial Motors Approximate Power Requirements For Farm/Home EquipmentIndustrial Motors Rating Starting Watts Running Watts Farm/Home Equipment Rating Starting Watts Running WattsApproximate Power Requirements For Contractor Equipment Contractor Rating Starting Watts Running WattsPower Required To Start Motor How Much Power Can Generator Supply?Single-Phase Induction Motor Starting Requirements KVA/HP x HP x 1000 = Starting AmperageTypical Connections To Supply Standby Power Selecting Extension Cord Use Shortest Cord Possible Current Load Watts Amperes− Parts List 109108 -2 107 101 102 103 100 104 106 105 81 Fig 7372 71 67 66 65 PC3 Dia Part Description Quantity Mkgs Batt Panel, Front w/Components Panel, Front w/Components -1ItemFUEL/HM Control Panel Generator Rectifier Assembly Wiring Harnesses Service Your distributor also givesSupport To locate a Distributor or Service Agency visit Miller Electric Mfg. CoFor assistance in filing or settling claims, contact Your distributor and/or equipment manufacturer’s