Miller Electric 300 P manual Fuel/Hm

Page 66

Item

Dia.

Part

Description

Quantity

No.

Mkgs.

No.

 

 

Figure 12-2. Panel, Front w/Components (Continued)

 

 

 

 

 

 

. . . 10 . .

. . . . . . . . . . .

. 214543 . .

Enclosure, Circuit Card Assy

. . . 1

. . . 11 . .

. . . . . . . . . . .

. 134201 . .

Stand−off Support, Pc Card .312/.375w/Post&lock .43

. . . 4

. . . 12 . .

. . PC2 . . . . 214660 . .

Circuit Card Assy, Display W/Program

. . . 1

. . . 13 . .

. . . R1 . . . .

. 214760 . .

Switch, Rotary 12 Posn 1p 200ma 28vdc W/Resistors

. . . 1

. . . 14 . .

. . . R2 . . . .

. 193118 . .

Pot, Cp Flat 1t 2. W 1k Ohm Linear

. . . 1

. . . 15 . .

. . . S4 . . . .

. 021467 . .

Switch, Tgl Spst 3a 250v Off−none−(On) Spd Term

. . . 1

. . . 16 . .

. . . S1 . . . .

. 212436 . .

Switch, Ignition 4 Position (Includes Knob)

. . . 1

. . . 17 . .

. . . . . . . . . . .

. 039047 . .

Terminal, Pwr Output Red

. . . 2

. . . 18 . .

. . . . . . . . . . .

. 010381 . .

Connector, Rectifier

. . . 3

. . . 19 .

C13, 14, 15 . 128750 . .

Capacitor, Cer Disc .1 Uf 500 Vdc W/Terms

. . . 3

. . . 20 . .

. . . . . . . . . . .

. 209056 . .

Cover, Receptacle W/Gasket

. . . 4

. . . 21 . .

. . RC11 . . .

. 182954 . .

Rcpt, Str 3p4w 50a 125/250v Flush Mtg *14−50

. . . 1

. . . 22 . .

. . . . . . . . . . .

. . . . . . . . . . .

Nameplate, Generator Power (Order By Model & Serial No.)

. . . 1

. . . 23 . .

. . . . . . . . . . .

. 213509 . .

Panel, Power

. . . 1

. . . 24 . .

. RC5,6 . . . 214918 . .

Rcpt,Str Dx Grd 2p3w 20a 125v *5−20r (Order By Model & Serial No.)

. . . 24 . .

GFCI1, 2 . . 151981 . .

Rcpt, Str Dx Grd 2p3w 15/20a 125v *5−20r Gfi (Order By Model & Serial No.)

. . . 25 . .

C11, C12 . . 217054 . .

Capacitor, Cer Disc .0047 Uf 3000 Vdc W/Terms

. . . 2

. . . 26 . .

CB4, CB6 .

. 093996 . .

Supplementary Pro, Man Reset 1p 20a 250vac Frict

. . . 2

. . . 27 . .

. . CB5 . . . . 203026 . .

Supplementary Protector, Man Reset 2p 50a 240vac

. . . 1

. . . 28 . .

. . GRD . . .

. 083030 . .

Stud, Brs .250−20 X 1.750 W/Hex Collar

. . . 1

. . . 29 . .

. . . . . . . . . . .

. 010915 . .

Washer, Flat .257idx0.640odx.031t Brs

. . . 4

. . . 30 . .

. . . . . . . . . . .

. 601836 . .

Nut, 250−20 .50hex .19h Brs

. . . 3

. . . 31 . .

. . . . . . . . . . .

. . . . . . . . . . .

Nameplate, Weld Terminal (Order By Model & Serial No.)

. . . 1

. . . 32 . .

. . . . . . . . . . .

. 181169 . .

Spacer, Output Stud

. . . 3

. . . 33 . .

. . . . . . . . . . .

. 186621 . .

Boot, Generic Output Stud

. . . 3

. . . 34 . .

. . . . . . . . . . .

. 180735 . .

Washer, Output Stud

. . . 3

. . . 35 . .

. . . . . . . . . . .

. 039046 . .

Terminal, Pwr Output Black

. . . 1

. . . 36 . .

FUEL/HM .

. 214768 . .

Gauge, Fuel Elec/Hour Meter

. . . 1

. . . 37 . .

. . . . . . . . . . .

. 021385 . .

Boot, Toggle Switch Lever

. . . 1

♦Optional

+When ordering a component originally displaying a precautionary label, the label should also be ordered.

To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested Replacement Parts. Model and serial number required when ordering parts from your local distributor.

OM-4433 Page 62

Image 66
Contents Description OM-4433218 314KProcesses File Engine DriveFrom Miller to You Table of Contents Warranty Symbol Usage Arc Welding HazardsEngine Hazards Compressed Air Hazards EMF Information Principal Safety StandardsCalifornia Proposition 65 Warnings Radiation can cause interferenceUN Choc Électrique peut tuer Signification des symboles− Consignes DE Sécurité − Lire Avant Utilisation LES Fumées ET LES GAZ peuvent être dangereuxDES Pièces Chaudes peuvent provoquer des brûlures graves LE Soudage peut provoquer un in- cendie ou une explosionDES Particules Volantes peuvent blesser les yeux LE Bruit peut affecter l’ouïe’EMPLOI Excessif peut LA Chaleur DU Moteur peut pro- voquer un incendie’AIR Comprimé peut provoquer des blessures LE Surchauffement peut endom- mager le moteur électriquePour les moteurs diesel LE Soudage À L’ARC risque de provoquer des interférencesPour les moteurs à essence Boulevard, Rexdale, Ontario, Canada M9W 1R3 téléphone− Definitions − 50 h StdStd Manufacturer’s Rating Label Symbols And Definitions − Specifications Weld, Power, And Engine SpecificationsDimensions, Weights, And Operating Angles TIG Mode Stick ModeMIG Mode Volt-Ampere CurvesFuel Consumption Curve shows typical fuel use under weld or power loadsExceeding duty cycle can damage unit and void warranty Duty Cycle And OverheatingAC Generator Power Curve 150 125 100See -2for lifting eye rating See -2for mounting information − InstallationInstalling Welding Generator GroundingMounting Welding Generator Stop engine and let cool Installing Exhaust PipeTools Needed 1/2 Point exhaust pipe in desired diDo not overfill battery cells Activating The Dry Charge Battery If ApplicableConnecting The Battery Close door after connecting batteryFuel Do not use gasoline. Gasoline will damage engine Coolant Recovery TankEngine Prestart Checks OilMIG and Fcaw Welding Connecting To Weld Output TerminalsStick and TIG Welding Stop engine350 ft 400 ft 45 m 60 m 70 m 90 m 105 m 120 m Selecting Weld Cable Sizes150 ft 200 ft 250 ft Stop engine beforeConnecting To Remote 14 Receptacle RC14 Socket Information− Operating Welding Generator Front Panel Controls See SectionDescription Of Front Panel Controls See Section Process/Contactor Switch Process/Contactor Switch SettingsDo not Strike Like a Match Lift-ArcStart ProcedureLift-Arc Start Method Touch Lift-Arc t TIGRemote Voltage/Amperage Control Generator Power Receptacles − Operating Auxiliary EquipmentAt least once a month, run engine at − Maintenance & Troubleshooting Routine MaintenanceMaintenance Label To clean air filter Servicing Air CleanerBy the warranty Do not clean housing with air hoseInspecting And Cleaning Optional Spark Arrestor Muffler Stop engine and let cool. Reinstall cleanout plugServicing Engine Cooling System Do not set engine speed higher Adjusting Engine Speed On Standard ModelsMaximum Stop engine. Close doorEngine Speed No Load Engine Speed AdjustmentWeld/Power Speed Adjust- ment Rpm max 62.6 Hz 1250 rpm 41.6 HzTo replace primary canister fuel filter Servicing Fuel And Lubrication SystemsTo change oil and filter To drain water from fuel systemOverload Protection Checking Generator Brushes Replace Damaged BrushesVoltmeter/Ammeter Help Displays Help 20 DisplayHelp 25 Display Troubleshooting WeldingGenerator Power EngineCheck for obstructed throttle solenoid Material Thickness Reference Chart − Electrical Diagrams Circuit Diagram For Welding Generator219 228−D − RUN-IN Procedure WetstackingWelding Generator Stop engine Do not touch hot exhaust Run-In Procedure Using Load BankProcedure at less than From flammables Do not PerformFrom flammables Run-In Procedure Using Resistance GridBank/grid Do not perform run-inSelecting Equipment − Generator Power GuidelinesHas this symbol Grounding Generator To Truck Or Trailer FrameEarth ground if supplying Grounding When Supplying Building SystemsHow Much Power Does Equipment Require? Use ground device as stated Electrical codesIndustrial Motors Rating Starting Watts Running Watts Approximate Power Requirements For Industrial MotorsApproximate Power Requirements For Farm/Home Equipment Farm/Home Equipment Rating Starting Watts Running WattsApproximate Power Requirements For Contractor Equipment Contractor Rating Starting Watts Running WattsSingle-Phase Induction Motor Starting Requirements Power Required To Start MotorHow Much Power Can Generator Supply? KVA/HP x HP x 1000 = Starting AmperageTypical Connections To Supply Standby Power Selecting Extension Cord Use Shortest Cord Possible Current Load Watts Amperes− Parts List 109108 -2 107 101 102 103 100 104 106 105 81 Fig 7372 71 67 66 65 PC3 Dia Part Description Quantity Mkgs Batt Panel, Front w/Components Panel, Front w/Components -1ItemFUEL/HM Control Panel Generator Rectifier Assembly Wiring Harnesses Service Your distributor also givesSupport For assistance in filing or settling claims, contact To locate a Distributor or Service Agency visitMiller Electric Mfg. Co Your distributor and/or equipment manufacturer’s