8-12. Troubleshooting
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Note | Also see Voltmeter/Ammeter help displays to assist in troubleshooting weld problems (see | ||||||||||||||||
|
|
|
|
|
|
| Section | ||||||||||
A. Welding |
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
| Trouble |
|
|
|
|
|
|
|
|
|
| Remedy | |||||
|
| ||||||||||||||||
No weld output; generator power output | Place Process/Contactor switch in a Weld Terminals Always On position, or place switch in a Remote | ||||||||||||||||
okay at ac receptacles. |
|
|
|
|
|
| On/Off Switch Required position and turn remote contactor on (see Section | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| Reset supplementary protector CB7 or CB8 (see Section | ||||
|
|
|
|
|
|
|
|
|
|
|
|
| to RC14. | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| Check and secure connections to Remote Control receptacle RC14 (see Section | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| Check Voltmeter/Ammeter help displays (see Section | ||||
|
| ||||||||||||||||
No weld output, or generator power out- | Disconnect equipment from generator power receptacles during | ||||||||||||||||
put at ac receptacles. |
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| Reset supplementary protector CB3. (see Section | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| Check fuse F1, and replace if open (see Section | ||||
|
|
|
|
|
|
|
|
|
|
|
|
| Agent check the voltage regulator module PC3. | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| Check Voltmeter/Ammeter help displays (see Section | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| Have Factory Authorized Service Agent check brushes and slip rings, voltage regulator module PC3, and | ||||
|
|
|
|
|
|
|
|
|
|
|
|
| field excitation circuit. | ||||
|
|
|
|
|
|
|
| ||||||||||
Erratic weld output. |
|
|
|
|
|
| Check and tighten connections inside and outside unit. | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| Be sure connection to work piece is clean and tight. | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| Use dry, properly stored electrodes. | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| Remove excessive coils from weld cables. | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| Have Factory Authorized Service Agent check brushes and slip rings. | ||||
|
|
|
|
|
|
|
| ||||||||||
High weld output. |
|
|
|
|
|
| Have Factory Authorized Service Agent check main control module PC1 and hall device HD1. | ||||||||||
|
|
|
|
|
|
|
| ||||||||||
Low weld output. |
|
|
|
|
|
| Check engine speed, and adjust if necessary. | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| Check fuse F1, and replace if open (see Section | ||||
|
|
|
|
|
|
|
|
|
|
|
|
| Agent check the rotor. | ||||
|
|
|
|
|
|
|
| ||||||||||
Low |
|
|
|
|
|
| Check engine speed, and adjust if necessary. | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| Have Factory Authorized Service Agent check main control module PC1, voltage regulator module PC3, | ||||
|
|
|
|
|
|
|
|
|
|
|
|
| and main rectifier. | ||||
|
| ||||||||||||||||
No remote fine amperage control. | Repair or replace remote control device. | ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| Check and secure connections to Remote Amperage Adjust receptacle RC14 (see Section | ||||
|
| ||||||||||||||||
No 24 volt or 115 volt ac output at Re- | Reset supplementary protector CB7 (24 volt) or CB8 (115 volt) (see Section | ||||||||||||||||
mote receptacle RC14. |
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|