1.9 Battery

WARNING

Sulfuric acid in batteries.

Can cause severe injury or death.

Wear protective goggles and clothing. Battery acid may cause blindness and burn skin.

WARNING

Explosion.

Can cause severe injury or death. Relays in the battery charger cause arcs or sparks.

Locate the battery in a well-ventilated area. Isolate the battery charger from explosive fumes.

Battery electrolyte is a diluted sulfuric acid. Battery acid can cause severe injury or death. Battery acid can cause blindness and burn skin. Always wear splashproof safety goggles, rubber gloves, and boots when servicing the battery. Do not open a sealed battery or mutilate the battery case. If battery acid splashes in the eyes or on the skin, immediately flush the affected area for 15 minutes with large quantities of clean water. Seek immediate medical aid in the case of eye contact. Never add acid to a battery after placing the battery in service, as this may result in hazardous spattering of battery acid.

Battery acid cleanup. Battery acid can cause severe injury or death. Battery acid is electrically conductive and corrosive. Add 500 g (1 lb.) of bicarbonate of soda (baking soda) to a container with 4 L (1 gal.) of water and mix the neutralizing solution. Pour the neutralizing solution on the spilled battery acid and continue to add the neutralizing solution to the spilled battery acid until all evidence of a chemical reaction (foaming) has ceased. Flush the resulting liquid with water and dry the area.

Battery gases. Explosion can cause severe injury or death. Battery gases can cause an explosion. Do not smoke or permit flames or sparks to occur near a battery at any time, particularly when it is charging. Do not dispose of a battery in a fire. To prevent burns and sparks that could cause an explosion, avoid touching the battery terminals with tools or other metal objects. Remove all jewelry before servicing the equipment. Discharge static electricity from your body before touching batteries by first touching a grounded metal surface away from the battery. To avoid sparks, do not disturb the battery charger connections while the battery is charging. Always turn the battery charger off before disconnecting the battery connections. Ventilate the compartments containing batteries to prevent accumulation of explosive gases.

Battery short circuits. Explosion can cause severe injury or death. Short circuits can cause bodily injury and/or equipment damage. Disconnect the battery before generator set installation or maintenance. Remove all jewelry before servicing the equipment. Use tools with insulated handles. Remove the negative (--) lead first when disconnecting the battery. Reconnect the negative (--) lead last when reconnecting the battery. Never connect the negative (--) battery cable to the positive (+) connection terminal of the starter solenoid. Do not test the battery condition by shorting the terminals together.

Connecting the battery and the battery charger. Hazardous voltage can cause severe injury or death. Reconnect the battery correctly, positive to positive and negative to negative, to avoid electrical shock and damage to the battery charger and battery(ies). Have a qualified electrician install the battery(ies).

Use a 12-volt battery with a minimum rating of 525 cold cranking amps at 0_F. The generator set uses a negative ground with a 12-volt engine electrical system. See Figure 1-21 for battery connections. Make sure that the battery is correctly connected and the terminals are tight.

12

EZ-273000-J

1.To positive (+) terminal on starter solenoid.

2.To ground (--) terminal on or near starter motor.

Figure 1-21 12-Volt Engine Electrical System Single Starter Motor Typical Battery Connection

24 Section 1 Installation

TP-6516 4/09

Image 24
Contents Models Controller DC-RET Digital ControlTP-6516 4/09d Product Identification Information Generator Set Identification NumbersEngine Identification Controller IdentificationTable of Contents TP-6516 4/09 Safety Precautions and Instructions BatteryAccidental Starting Engine Backfire/Flash Fire Exhaust SystemFuel System Hazardous Noise Hazardous Voltage/ Moving PartsHeavy Equipment Hot Parts Introduction DetailGenerator Set Component Locations, 17/18 kW Models Service Assistance TP-6516 4/09 Installation GeneralLifting Generator Set InspectionSee Section Generator Set Clearances, 12 kW Models, ADV-7466, Sheet Installation TP-6516 4/09 Generator Set Clearances, 17/18 kW Models, ADV-7341-B, Sheet Power Supply Exhaust RequirementsAir Requirements Fuel Requirements Fuel SupplyFuel Conversion Fuel Pipe SizeFuel Conversion 17 Dsai Connection Electrical Connections AC ConnectionsBattery Charger Remote Start ConnectionGrounding EZ-273000-J Engine starting battery location Carburetor Heater optional 24 Carburetor Heater, 17/18 kWPrestart Installation Check Startup NotificationInstallation TP-6516 4/09 Wiring Diagrams Wiring Diagrams and SchematicsSchematic Diagram, 12 kW Models, ADV-7351 Point-to-Point Wiring Diagram, 12 kW Models, GM52471 Schematic Diagram, Single Phase, 17/18 kW Models, ADV-7353 TP-6516 4/09 Wiring Diagrams Wiring Diagrams TP-6516 4/09 Appendix a Abbreviations AnsiLCB TP-6516 4/09 TP-6516 4/09 Page 2007, 2008, 2009 by Kohler Co. All rights reserved