Kohler 12RESM1 manual Generator Set Component Locations, 17/18 kW Models

Page 10

Control detail, top view

8

 

12

9

11

10

1

2 3 4

5 6

7 See control detail

18

19

20 21

22

26

25

17

23

ADV-7341A-B

 

16

15 14

13

 

24

1.

Muffler

 

 

14.

Oil drain hose

2.

Oil check

 

 

15.

Nameplate location (on base)

3.

Oil fill

 

 

16.

Oil drain valve

4.

Air cleaner

 

 

17.

Exhaust outlet

5.

Spark plug locations (both sides)

 

 

18.

Field-connection terminal block location

6.

Oil filter

 

 

19.

LP fuel orifice location (inside hose fitting)

7.

Oil cooler location

 

 

20.

Gas regulator assembly

8.

DC-RET Digital Control display

 

 

21.

DSAI leads

9.

Generator set master switch (RUN-OFF/RESET-AUTO)

 

22.

Fuel inlet

10.

Line circuit breaker

 

 

23.

Air intake

11.

Fuses

 

 

24.

Battery cables

12.

RS-232 connector (for application program updates)

 

 

25.

Battery charger

13.

Engine starting battery location (battery purchased separately)

 

26.

120 VAC receptacle for battery charger

Figure 2 Generator Set Component Locations, 17/18 kW Models

10

TP-6516 4/09

Image 10
Contents Controller DC-RET Digital Control ModelsTP-6516 4/09d Engine Identification Product Identification InformationGenerator Set Identification Numbers Controller IdentificationTable of Contents TP-6516 4/09 Battery Safety Precautions and InstructionsAccidental Starting Exhaust System Engine Backfire/Flash FireFuel System Hazardous Voltage/ Moving Parts Hazardous NoiseHeavy Equipment Hot Parts Introduction DetailGenerator Set Component Locations, 17/18 kW Models Service Assistance TP-6516 4/09 Lifting InstallationGeneral Generator Set InspectionSee Section Generator Set Clearances, 12 kW Models, ADV-7466, Sheet Installation TP-6516 4/09 Generator Set Clearances, 17/18 kW Models, ADV-7341-B, Sheet Exhaust Requirements Power SupplyAir Requirements Fuel Requirements Fuel SupplyFuel Pipe Size Fuel ConversionFuel Conversion 17 Dsai Connection Electrical Connections AC ConnectionsRemote Start Connection Battery ChargerGrounding EZ-273000-J Engine starting battery location Carburetor Heater optional 24 Carburetor Heater, 17/18 kWPrestart Installation Check Startup NotificationInstallation TP-6516 4/09 Wiring Diagrams Wiring Diagrams and SchematicsSchematic Diagram, 12 kW Models, ADV-7351 Point-to-Point Wiring Diagram, 12 kW Models, GM52471 Schematic Diagram, Single Phase, 17/18 kW Models, ADV-7353 TP-6516 4/09 Wiring Diagrams Wiring Diagrams TP-6516 4/09 Appendix a Abbreviations AnsiLCB TP-6516 4/09 TP-6516 4/09 Page 2007, 2008, 2009 by Kohler Co. All rights reserved