Honeywell 6039 owner manual Engine ON/OFF Switch

Page 12

Operation

Figure 12 - Engine ON/OFF Switch

Never start or stop engine with electrical devices plugged into the receptacles AND devices turned on.

1.Unplug all electrical loads from the unit's receptacles before starting the engine.

2.Make sure the unit is in a level position (not to exceed 15° in any direction).

3.OPEN the Fuel Shut-off Valve (Figure 10).

4.Turn engine RUN/STOP switch to ON position (Figure 12).

5.Slide engine choke to the LEFT to FULL CHOKE position (Figure 11).

6.To start engine, firmly grasp the recoil handle and pull slowly until increased resistance is felt. Pull rapidly up and away.

7.When engine starts, move choke knob to 1/2-CHOKE position until engine runs smoothly and then fully into RUN position. If engine falters, move choke back out to 1/2-CHOKE position until engine runs smoothly and then to RUN position.

NOTE:

If engine fires, but does not continue to run, move choke lever to FULL CHOKE and repeat starting instructions.

Figure 10 - Fuel Shut-off Valve

Figure 11 - Choke Position

CHOKE LEVER

LEFT = CHOKE (START)

RIGHT = RUN

IMPORTANT: Do not overload the generator. Also, do not overload individual panel receptacles. These outlets are protected against overload with push-to-reset-type circuit breakers. If amperage rating of any circuit breaker is exceeded, that breaker opens and electrical output to that receptacle is lost. Read “Don’t Overload the Generator” carefully.

Never start or stop engine with electrical devices plugged into the receptacles AND devices turned on.

1.Unplug all electrical loads from the unit's receptacles before starting the engine.

2.Make sure the unit is in a level position (not to exceed 15° in any direction).

3.Open the fuel shut-off valve (Figures 10).

4.Move engine CHOKE knob outward to FULL CHOKE position (Figure 11).

5.To start engine, press and hold the Start/Run/Stop switch in the “Start” position. The engine will crank and attempt to start. When the engine starts, release the switch to the run position.

6.When the engine starts, move choke knob to “1/2 Choke” position until the engine runs smoothly and then fully in to the “Run” position. If engine falters, move choke knob back out to “1/2 Choke” position until the engine runs smoothly and then to “Run” position.

This generator is also equipped with a manual recoil starter which may be used if the battery is discharged.

10

Image 12
Contents Portable Generator Table of Contents Introduction Avoided, could result in death or serious injurySafety Rules Exhaust & Location HazardsModel no Serial no – Handle Assembly General Information– Wheel Assembly OperationGenerator Controls 120/240 VAC, 30 Amp Receptacle Grounding the Generator Clean area around fuel fill cap, remove cap Install fuel cap and wipe up any spilled gasoline• Below 10 F, use synthetic 5W-30 YIP 3238*MPP%FSZI0MTEngine ON/OFF Switch Maintenance Move Run/Stop switch to OFF position Close fuel valveCheck Valve Clearance Every Season Service Air Filter Check Oil Level At Each Use Change Oil ‡Replace Spark Plug Every Season • Air Induction System • Ignition SystemSpark Plug Gap To clean or replace paper air filter Remove air filter cover and remove paper filterAvoid spray from spark plug hole when cranking engine Troubleshooting Problem Cause CorrectionPage Warranty BOX 297 WHITEWATER, WIEmission Related Parts MAY Include the Following if Equipped Generac Power SYSTEMS, INC Ignition Coils / Module Warranty Schedule