Honeywell 6039 Check Oil Level At Each Use Change Oil ‡, Replace Spark Plug Every Season

Page 14

Maintenance

Follow the calendar intervals. More frequent service is required when operating in adverse conditions noted below.

Check Oil Level

At Each Use

Change Oil ‡

*Every 100 hours or Every Season

Check Valve Clearance

***Every Season

Service Air Filter

** Every 200 hours or Every Season

Replace Spark Plug

Every Season

‡Change oil after first 30 hours of operation then every season.

*Change oil and oil filter every month when operating under heavy load or in high temperatures.

**Clean more often under dirty or dusty operating conditions. Replace air filter parts if they cannot be adequately cleaned.

***Check valve clearance and adjust if necessary after first 50 hours of operation and every 100 hours thereafter.

5.5 kW

 

Rated Power

5.5 kW**

Surge Power

6.8 kW**

Rated AC Voltage

120/240

Rated Max AC Load

 

Current @ 240V

22.9 Amps**

Current @120V

45.8 Amps**

Rated Frequency

60 Hz @3600 RPM

Phase

Single Phase

6.5 kW

 

Rated Power

6.5 kW**

Surge Power

8.1 kW**

Rated AC Voltage

120/240

Rated Max AC Load

 

Current @ 240V

27.1 Amps**

Current @120V

54.2 Amps**

Rated Frequency

60 Hz @3600 RPM

Phase

Single Phase

7.5 kW

 

Rated Power

7.5 kW**

Surge Power

9.4 kW**

Rated AC Voltage

120/240

Rated Max AC Load

 

Current @ 240V

31.3 Amps**

Current @120V

62.5 Amps**

Rated Frequency

60 Hz @3600 RPM

Phase

Single Phase

**Maximum wattage and current are subject to, and limited by, such factors as fuel Btu content, ambient temperature, altitude, engine condition, etc.. Maximum power decreases about 3.5% for each 1,000 feet above sea level; and will also decrease about 1% for each 6° C (10° F) above 16° C (60° F) ambient temperature.

5.5 & 6.5 kW

 

Displacement

389cc

Spark Plug Type

NHSP LDF7TC or Champion N9YC

Spark Plug Gap

0.028-0.031 inches (0.70-0.80 mm)

Spark Plug Part Number

0J00620106

Gasoline Capacity

5.8 U.S. Gallons

Oil Type

See Chart in “Adding Engine Oil” Section

Oil Capacity

1 L (1.06 Qts.)

Run Time (50% Load)

9 hrs.

7.5 kW

 

Displacement

420cc

Spar Plug Type

NHSP LDF7TC or Champion N9YC

Spark Plug Gap

0.030 inch (0.76 mm)

Spark Plug Part Number

0J00620106

Gasoline Capacity

5.8 U.S. Gallons

Oil Type

See Chart in “Adding Engine Oil” Section

Oil Capacity

1 L (1.06 Qts.)

Run Time (50% Load)

8 hrs.

The Environmental Protection Agency (and California Air Resource Board for generators certified to CA standards) require(s) that this generator comply with exhaust and evaporative emission standards. Locate the emissions compliance decal on the engine to determine what standards the generator meets. This generator is certified to operate on gasoline. The emission control system includes the following components (if equipped):

• Air Induction System

• Ignition System

~

Intake Pipe / Manifold

~

Spark Plug

~

Air Cleaner

~

Ignition Module

• Fuel System

• Exhaust System

~

Carburetor

~

Exhaust Manifold

~

Fuel Tank / Cap

~

Muffler

~

Fuel Lines

~

Pulsed Air Valve

~

Evaporative Vent Lines

~

Catalyst

~

Carbon Canister

 

 

The warranty of the generator does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, the operator must maintain the generator as instructed in this manual.

Some adjustments will need to be made periodically to properly maintain the generator.

All adjustments in the Maintenance section of this manual should be made at least once each season. Follow the requirements in the "Maintenance Schedule".

NOTE:

Once a year replace the spark plug and replace the air filter. A new spark plug and clean air filter assure proper fuel-air mixture and help the engine run better and last longer.

12

Image 14
Contents Portable Generator Table of Contents Introduction Avoided, could result in death or serious injurySafety Rules Exhaust & Location HazardsModel no Serial no – Handle Assembly General Information– Wheel Assembly OperationGenerator Controls 120/240 VAC, 30 Amp Receptacle Grounding the Generator • Below 10 F, use synthetic 5W-30 Clean area around fuel fill cap, remove capInstall fuel cap and wipe up any spilled gasoline YIP 3238*MPP%FSZI0MTEngine ON/OFF Switch Maintenance Move Run/Stop switch to OFF position Close fuel valveReplace Spark Plug Every Season Check Valve Clearance Every Season Service Air FilterCheck Oil Level At Each Use Change Oil ‡ • Air Induction System • Ignition SystemSpark Plug Gap To clean or replace paper air filter Remove air filter cover and remove paper filterAvoid spray from spark plug hole when cranking engine Troubleshooting Problem Cause CorrectionPage Warranty BOX 297 WHITEWATER, WIEmission Related Parts MAY Include the Following if Equipped Generac Power SYSTEMS, INC Ignition Coils / Module Warranty Schedule