17.Battery Charger Input – This receptacle allows the capability to recharge the 12 volt DC storage battery provided with the 12 Volt Adaptor Plug Charger which is included in the Accessory Box. Located behind the battery charger input is a 1.50 Amp in-line fuse which is inside the control panel to protect the battery (electric start models only).

18.Battery – Powers the electric starter (electric start models only).

Figure 3 - Generator Controls

Figure 4 - Generator Controls

This is a 120 Volt outlet protected against overload by a 20 Amp push-to-reset circuit breaker (Figure 5). Use each socket to power 120 Volt AC, single phase, 60 Hz electrical loads requiring up to a combined 2400 watts (2.4 kW) or 20 Amps of current. Use only high quality, well-insulated, 3-wire grounded cord sets rated for 125 Volts at 20 Amps (or greater).

Keep extension cords as short as possible, preferably less than 15 feet long, to prevent voltage drop and possible overheating of wires.

Figure 5 - 120 Volt AC, 20 Amp, Duplex Receptacle

This is a 120 Volt outlet protected against overload by a 20 Amp push-to-reset circuit breaker (Figure 6). Use each socket to power 120 Volt AC, single phase, 60 Hz electrical loads requiring up to a combined 2400 watts (2.4 kW) or 20 Amps of current. Use only high quality, well-insulated, 3-wire grounded cord sets rated for 125 Volts at 20 Amps (or greater).

Keep extension cords as short as possible to prevent voltage drop and possible overheating of wires.

Figure 6 - 120 Volt AC, 20 Amp, GFCI Duplex Receptacle

6

Image 8
Contents Portable Generator Table of Contents Introduction Avoided, could result in death or serious injurySafety Rules Exhaust & Location Hazards Model no Serial no – Handle Assembly General Information– Wheel Assembly OperationGenerator Controls 120/240 VAC, 30 Amp Receptacle Grounding the Generator Clean area around fuel fill cap, remove cap Install fuel cap and wipe up any spilled gasoline• Below 10 F, use synthetic 5W-30 YIP 3238*MPP%FSZI0MTEngine ON/OFF Switch Maintenance Move Run/Stop switch to OFF position Close fuel valveCheck Valve Clearance Every Season Service Air Filter Check Oil Level At Each Use Change Oil ‡Replace Spark Plug Every Season • Air Induction System • Ignition SystemSpark Plug Gap To clean or replace paper air filter Remove air filter cover and remove paper filterAvoid spray from spark plug hole when cranking engine Troubleshooting Problem Cause CorrectionPage Warranty BOX 297 WHITEWATER, WIEmission Related Parts MAY Include the Following if Equipped Generac Power SYSTEMS, INC Ignition Coils / Module Warranty Schedule