Hearth and Home Technologies BODBAY Installation in Canada, Leveling Bolts and sheet metal shims

Page 11

BODEGA BAY WOOD INSERT

INSTALLATION IN CANADA

MASONRY and HEAT-CIRCULATING

(INSTALLATIONS INTO FACTORY-BUILT FIREPLACES ARE PROHIBITED IN CANADA)

R

Whether installed in a masonry or heat-circulating fireplace, this fireplace insert must be installed with a continuous chim- ney liner of six inch (152mm) diameter extending from the fireplace insert to the top of the chimney. The chimney liner must conform to the Class 3 requirements of CAN/ULC-S635, Standard for Lining Systems for Existing Masonry or Factory-Built Chimneys and Vents, or CAN/ULC-S640, Standard for Lining Systems for New Masonry Chimneys.

Do not remove bricks or mortar from fireplace to accommodate insert.

The face of the fireplace must be sealed to prevent room air passage into the chimney cavity.

The permanent metal warning label provided must be affixed to the back of the fireplace with screws or nails to the fireplace, in a location readily visible should the fireplace insert by removed, stating that the fireplace may have been altered to accommodate the insert, and must be returned to original condition for use as a conventional fireplace.

Circulating air chambers may not be blocked.

Leveling Bolts and sheet metal shims

The insert is shipped with 2 leveling bolts and 2 sheet metal guides for ease in sliding the insert into place when using the leveling bolts. Not all installations will require the use of the leveling bolts. The sheet metal guides are used only when the leveling bolts are necessary. Discard if not needed.

cut-out view

Leveling Bolt

Reach between side of insert and outer skin

Figure 11A

SHEET METAL GUIDES

Slide each guide under the insert on each side placing them directly under leveling bolts. If they are not directly under the bolts, the bolts may hang up on uneven material when sliding the insert into place. See Figure 11B.

ADUSTING THE LEVELING BOLTS

It is best to use a 1/2” (12.7mm) socket wrench with an extended handle for ease in adjusting bolts to the desired level. The bolts will adjust from 0 inches to 2 inches (0 - 51mm). You can also reach in and adjust the bolts by hand, although space is limited. See Figure 11A.

Sheet Metal Shims

Place under leveling bolts and slide insert into place

Leveling Bolts

Figure 11B

August 20, 2008

435-1320B

Page 11

Image 11
Contents Bodbay Installation and Operation ModelImportant Safety Notes Advanced Combustion Technology ACTTest Lab Report No Manufactured Date Sample of Serial Number / Safety LabelBodega BAY Wood Insert Location On Beaded Chain, Left Side Behind Outer SkinTable of Contents Clearances to Combustibles TOP ViewSide View Front ViewChimney HEIGHT/DRAFT Installation recommendationsListings Alternate Floor Protection Worksheet General Installation ProcedureChimney TOP View Chimney RequirementsOvalizing Round Stainless Steel Liners Imney HeightInstallations Into Zero Clearance Fireplaces in Mobile Homes Masonry Fireplace Using DIRECT-CONNECT Method Installation OptionsFactory built zero clearance fireplace Usa installatons onlyMasonry and HEAT-CIRCULATING Installation in CanadaLeveling Bolts and sheet metal shims Securing Liner to Chimney Ring Outside AIR InstallationPanel and Gold or Nickel Trim SET Door Handle AssemblyDoor Latch Adjustment Blower Cord Location & Blower Control BOX with Switch Zero Clearance Adjustable Trim SUPPORT, 2 to Wood Selection and Storage OverfiringBuilding a Fire ASH Removal Bodega BAY Wood Insert Operating TipsFan operating instructions Story of the Three Burning Stages Air quality and your Quadra-Fire InsertMaintenance Baffle Removal & Installation Brick replacement instructions PartCeramic Blanket Exploded ViewAppliance AccessoriesService Parts Warranty Policy Lifetime WarrantyBodega Bay Wood Insert