Hearth and Home Technologies BODBAY Securing Liner to Chimney Ring, Outside AIR Installation

Page 12

R

BODEGA BAY WOOD INSERT

SECURING LINER TO CHIMNEY RING

There are 2 options to secure the liner to the chimney ring: (See Figure 12A).

Option One: If there is enough room on the top of the insert to work, hand bend the two tabs upward 90°. Secure the liner with the supplied hex head bolts 1/4- 20-3/4.

Option Two: Remove the manifold tubes, fiberboard baffle and ceramic blanket. From inside the firebox, pull liner down through the chimney ring below the outer skin. There are 2 pre-drilled holes in the chimney ring 180° apart. Secure the liner with the supplied hex head bolts 1/4-20-3/4.

NOTE: Tabs are shipped from factory in a flat position. Bend upwards 90 degrees.

2 pre-drilled holes on chimney ring under outer skin (access through firebox)

Attach liner with 2 tabs

Figure 12A

OUTSIDE AIR INSTALLATION

1. Remove plate

2. Re-install using same screws

Figure 12B

Tools Needed: Phillips Head Screwdriver

1.Remove 3 screws and cover plate from back side of insert. Save the screws.

2.Reattach the cover plate using the same screws to front side of the insert as shown in Figure 12B.

3.Repeat same procedure for other side of insert.

NOTE: This product requires replacement of combustion air. If your home is fairly air-tight, it is recommended that you install outside air. If you are installing into a Mobile Home, outside air is required. See page 8.

Page 12

435-1320B

August 20, 2008

Image 12
Contents Installation and Operation Model Important Safety NotesAdvanced Combustion Technology ACT BodbaySample of Serial Number / Safety Label Bodega BAY Wood InsertLocation On Beaded Chain, Left Side Behind Outer Skin Test Lab Report No Manufactured DateTable of Contents TOP View Side ViewFront View Clearances to CombustiblesInstallation recommendations ListingsChimney HEIGHT/DRAFT General Installation Procedure Alternate Floor Protection WorksheetChimney Requirements Ovalizing Round Stainless Steel LinersImney Height Chimney TOP ViewInstallations Into Zero Clearance Fireplaces in Mobile Homes Installation Options Masonry Fireplace Using DIRECT-CONNECT MethodUsa installatons only Factory built zero clearance fireplaceInstallation in Canada Leveling Bolts and sheet metal shimsMasonry and HEAT-CIRCULATING Outside AIR Installation Securing Liner to Chimney RingDoor Handle Assembly Door Latch AdjustmentPanel and Gold or Nickel Trim SET Blower Cord Location & Blower Control BOX with Switch Zero Clearance Adjustable Trim SUPPORT, 2 to Overfiring Building a FireWood Selection and Storage Bodega BAY Wood Insert Operating Tips Fan operating instructionsASH Removal Air quality and your Quadra-Fire Insert Story of the Three Burning StagesMaintenance Brick replacement instructions Part Baffle Removal & InstallationExploded View Ceramic BlanketAccessories Service PartsAppliance Lifetime Warranty Warranty PolicyBodega Bay Wood Insert